Difference between revisions of "Join and Reset Instructions"

From Hubitat Documentation
Jump to: navigation, search
(Added Dragon Tech PD-100, Eaton RF9540 and Ecolink DWZWAVE2.5-ECO)
(Modified device brand and type visibility)
Line 2: Line 2:
  
 
=='''<big>ADT</big>'''==
 
=='''<big>ADT</big>'''==
<big>'''ADT Water Leak Detector'''</big>
+
{| class="wikitable sortable"
 
+
|Brand
 +
|Device
 +
|Product Number
 +
|Device Type
 +
|Protocol
 +
|-
 +
|'''ADT (Nortek)'''
 +
|'''Water Leak Detector'''
 +
|'''10016864C'''
 +
|'''Water Sensor'''
 +
|'''Zigbee'''
 +
|}
 
'''Factory Reset'''
 
'''Factory Reset'''
  
Line 1,320: Line 1,331:
 
<hr />
 
<hr />
  
== '''<big>Dragon Tech</big>''' ==
+
=='''<big>Dragon Tech</big>'''==
 
'''<big>Dragon Tech Plug in Z-Wave Plus Dimmer Switch  PD-100</big>'''  
 
'''<big>Dragon Tech Plug in Z-Wave Plus Dimmer Switch  PD-100</big>'''  
  
Line 1,345: Line 1,356:
 
<hr />
 
<hr />
  
== <big>'''Eaton''' '''(Cooper Wiring Devices)'''</big> ==
+
==<big>'''Eaton''' '''(Cooper Wiring Devices)'''</big>==
 
'''<big>Z-Wave Wireless Dimmer  RF9540</big>'''  
 
'''<big>Z-Wave Wireless Dimmer  RF9540</big>'''  
  
Line 1,370: Line 1,381:
  
 
<hr />
 
<hr />
=='''<big>Ecolink</big>''' ==
+
=='''<big>Ecolink</big>'''==
 
'''<big>Ecolink Door / Window Sensor  DWZWAVE2.5-ECO</big>'''
 
'''<big>Ecolink Door / Window Sensor  DWZWAVE2.5-ECO</big>'''
  

Revision as of 15:43, 19 May 2019

Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into Paring Mode using the manufacturer's instructions, Z-Wave devices must be Excluded from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation™, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a General Exclusion in your Hubitat Elevation™ hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show Unknown Device Excluded in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See How to Build a Solid Z-Wave Mesh for further detail on methods of Exclusion.

ADT

Brand Device Product Number Device Type Protocol
ADT (Nortek) Water Leak Detector 10016864C Water Sensor Zigbee

Factory Reset

  1. Remove the cover by rotating it counterclockwise
  2. Press and hold the Connect button for 5 seconds
  3. After the button is released, the LED will blink quickly for a few seconds, go dark for a few seconds, then blink slowly to indicate it is in pairing mode.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. Remove the cover by rotating it counterclockwise
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press and hold the Connect button for 5 seconds
  4. After the button is released, the LED will blink quickly for a few seconds, go dark for a few seconds, then blink slowly to indicate it is in pairing mode

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

AduroSmart

AduroSmart ERIA Contact Sensor

Factory Reset

  1. Use the provided pin to press and hold the reset button for 10 seconds.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Use the provided pin to press and hold the reset button for 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

AduroSmart ERIA Dimmer Switch

Factory Reset

  1. Hold down the two middle buttons until the light flashes green. A red flash indicates an unsuccessful reset.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Hold down the off (circle) button for 10 seconds until it blinks green 3 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

AduroSmart ERIA Motion Sensor

Factory Reset

  1. Use the provided pin to press and hold the reset button for 10 seconds.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Use the provided pin to press and hold the reset button for 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Aeotec (Aeon Labs)

Aeotec* Doorbell Gen5 ZW056

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Doorbell will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow blinking as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Doorbell Gen5, and its LED will blink rapidly to indicate that it is communicating.
  3. If your Doorbell has been successfully linked to your network, its LED will become solid for 2 seconds, then stop. If linking was unsuccessful, the LED will blink when you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Doorbell.
  4. If your Doorbell has been successfully unlinked to your network, its LED will begin to blink slowly indicating it is ready to be paired to a new network..

Aeotec* Door/Window Sensor 6

Factory Reset

  1. Press and hold Door Window Sensor 6 Action button
  2. Wait until the RGB LED turns into a Green Color, and then release. (LED will change from Yellow, Purple, Red, then to Green)
  3. If your MultiSensor has been successfully factory reset from its previous network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will blink. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Tap the button on the Door Window Sensor 6
  3. The LED will blink green to indicate successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your Door Window Sensor is successfully removed from the Z-Wave network, the RGB LED will become a colorful gradient for a few seconds and then turn off. If the removing was unsuccessful, the RGB LED will be solid for 8 seconds and then turn off, repeat the above steps.

Aeotec* Door/Window Sensor Gen5

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once to include the door/window sensor.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your Door Window Sensor has been successfully removed from your Z-Wave network, its Status LED will fast blink for 8 seconds and then slow blink for 3 seconds when you press the Action Button again.
  5. If the removal was unsuccessful, the Status LED will fast blink for 2 seconds and then be solid for 2 seconds when you press the Action Button, repeat the above steps.

Aeotec* Door/Window Sensor Gen2

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once to include the door/window sensor.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor to exclude it from the network

Aeotec* Door/Window Sensor 1E DSB04100

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the sensor to a default state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the security tamper switch located at the back of the Aeon Labs Door/Window Sensor to include it in the network
  3. The sensor will now stay awake for 10 minutes to receive network instructions. The LED on the will be blinking while awake.
    • Note: The DSB04100 sensor can only be taught to communicate to devices within it’s own network.
    • If the Aeon Labs Door / Window Sensor was not included in a Z-Wave network, pressing the security switch will illuminate the LED solid red on the front of the sensor for 5 seconds.
    • If the sensor was successfully included in the Z-Wave network, the LED will blink instead of staying solid.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Use an Aeon Z-Stick or Minimote to exclude the sensor from previous networks

Aeotec* Garage Door Controller Gen5 ZW062

Factory Reset

  1. Press and hold the Action Button for 20 seconds and release.
  2. Your Garage Door Controller will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow blinking to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Z-Wave Button on the Garage Door Controller.
  3. The LED on Garage Door Controller will blink rapidly, followed by a solid LED for 1-2 second for a successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on the Garage Door Controller.
  4. The LED on Garage Door Controller will blink rapidly, followed by a solid LED for 1-2 second for a successful exclusion.
  5. The Network LED on the Garage Door Controller should now be blinking slowly to indicate it is ready to be paired to a new network.

Aeotec* Dry Contact Sensor Gen5 ZW097

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Sensor.
  3. If your Sensor has been successfully linked to your network, its LED will become solid for 2 seconds then disappear. If linking was unsuccessful, the LED will continue to blink if you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your switch has been successfully unlinked to your network, its LED will begin to blink for a short time. If linking was unsuccessful, the LED will return to its last state. Tap the button to confirm if it has been unpaired, if unpaired successfully, the LED will blink when tapped.

Aeotec* (Aeon Labs AEDSB09104ZWUS) Home Energy Meter

Factory Reset

  1. Press and hold the Action Button for 10 seconds.
  2. If successful, the LED on the HEM should begin to blink slowly.

Join the Z-Wave Network

  1. Remove the screw from the back of your Reader and open the battery cover.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the Action Button (small black button under the battery tray) on your reader. If your Reader has been successfully linked to your network, its light will remain solid for 1 second. If the linking was unsuccessful the light will blink after pressing your meter’s Action Button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the screw from the back of your Reader and open the battery cover.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Press the Action Button (small black button under the battery tray) on your reader.If your Reader has been successfully removed from your network its light will blink for 1 second. If the removal was unsuccessful the light will be solid after pressing your meter’s Action Button.

Aeotec* Home Energy Meter Gen2 / Gen5 ZW095

Factory Reset

  1. Press and hold the Action Button for 10 seconds.
  2. If successful, the LED on the HEM should begin to blink slowly.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. Press the Action Button on your HEM. If it has been successfully linked to your  network, its LED will remain illuminated. If the linking was unsuccessful, your HEM’s LED will continue to blink.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your HEM. If it has been successfully removed from your  network, its LED will blink. If the removal was unsuccessful, its LED will be solid and it will be then repeated again.

Aeotec* LED Bulb Gen5 ZW098

Factory Reset

  1. Removing LED Bulb from your Z-Wave network will reset LED Bulb to default factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, wait 2 seconds. Now toggle your wall switch ON. LED Bulb’s green LED will blink to indicate that it is looking for a Z-Wave network to connect to.
  3. After successfully connecting to your network, LED Bulb will illuminate. If a network connection has failed, it will remain without light.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Turn LED Bulb’s wall switch on.
  4. Toggle LED Bulb’s wall switch off, on, off, on, off, on within 2 seconds. The LED should flash orange, and if successful, the orange LED will be solid for 2 seconds before becoming a white color. LED Bulb should now be removed from your Z-Wave network.
  5. To confirm successful removal its color will change to orange for 2 seconds before changing to white. If removal was unsuccessful, LED Bulb will blink orange for 3 seconds before changing to red for 2 seconds.

Aeotec* LED Bulb 6 Multi-Color ZWA002

Factory Reset

  1. Turn LED Bulb’s wall switch on and wait 1 second.
  2. Toggle LED Bulb's wall switch 6 times (off -> on, off -> on, off -> on, off -> on, off -> on, off -> on) between 0.5 - 2 seconds per re-power.
  3. If successful, the LED Bulb 6 Multi-Color will change to a warm white, solid yellow, then flash red -> white 3 times to indicate a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, toggle your wall switch ON. LED Bulb’s LED will turn into a solid yellow color to indicate that it is in pair mode up to 10 seconds.
  3. After successfully connecting to your network, LED Bulb will flash green -> white color for 3 seconds. If a network connection has failed, LED Bulb 6 Multi-Color will flash red -> white for 3 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle LED Bulb’s wall switch 3 times (off > on, off > on, off > on) between 0.5 - 2 seconds per cycle.
  4. LED Bulb 6 has been unpaired successfully, the LED will flash blue > white for 3 seconds.

Aeotec* LED Bulb 6 Multi-White ZWA001

Factory Reset

  1. Turn LED Bulb’s wall switch on and wait 1 second.
  2. Toggle LED Bulb's wall switch 6 times (off -> on, off -> on, off -> on, off -> on, off -> on, off -> on) between 0.5 - 2 seconds per re-power.
  3. If successful, the LED Bulb 6 Multi-White will flash twice to indicate that it successfully reset itself to factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, toggle your wall switch ON. LED Bulb’s LED will blink 2x times to indicate that it is looking for a Z-Wave network to connect to.
  3. After successfully connecting to your network, LED Bulb will blink off then on in about half a second to indicate that it attempted to pair to your network. If a network connection has failed, LED Bulb 6 Multi-White will not react.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Turn LED Bulb’s wall switch on and wait 1 second.
  4. Toggle LED Bulb’s wall switch 3 times (off > on, off > on, off > on) between 0.5 - 2 seconds per cycle.
  5. LED Bulb 6 if successful will flash once, dim to 5% for 5 seconds, then increase to 100% dim level to indicate a successful unpair and factory reset.

Aeotec* Micro Illuminator G2 DSC19103-ZWUS

Factory Reset

  1. Hold the Z-Wave button for 30 seconds and release it to reset the entire module including Z‐Wave to factory default settings (the LED will stay solid after holding the button for 30 seconds).

Join the Z-Wave Network

  1. Connect Micro Smart Dimmer to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the Z‐Wave button.
  4. If the inclusion fails, please repeat the process from step 2.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z‐Wave button.
  4. If the exclusion fails, please repeat the process from step 2

Aeotec* Micro Motor Controller DSC14104-ZWEU/US, DSC14103-ZWAU

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the controller to a default state.

Join the Z-Wave Network (Z-Stick)

  1. Connect Micro Motor Controller to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. Press the Action Button on your Micro Motor Controller.
  5. If Micro Motor Controller has been successfully linked to your Z-Wave network, its Network LED will no longer blink.
  6. If the linking was unsuccessful and the Network LED continues to blink repeat the above steps.
  7. Press the Action Button on the Z-Stick to take it out of installation mode.

Join the Z-Wave Network (Minimote)

  1. Connect Micro Motor Controller to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the Include button on your Minimote.
  4. Press the Action Button on your Micro Motor Controller.
  5. If the Micro Motor Controller has been successfully linked to your Z-Wave network, its Network LED will no longer blink.
  6. If the linking was unsuccessful and the Network LED continues to blink repeat the above steps.
  7. Press any button on your Minimote to take it out of inclusion mode.

Exclusion from the Z-Wave Network (Z-Stick)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. Press the Action Button on your Micro Motor Controller.
  5. If your Micro Motor Controller has been successfully removed from your network, its Network LED will blink.
  6. If the removal was unsuccessful, the Network LED will not blink.
  7. Press the Action Button on the Z-Stick to take it out of removal mode.

Exclusion from the Z-Wave Network (Minimote)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Remove Button on your Minimote.
  4. Press the Action Button on your Micro Motor Controller.
  5. If your Micro Motor Controller has been successfully removed from your network, its Network LED will blink.
  6. If the removal was unsuccessful, the Network LED will not blink.
  7. Press any button on your Minimote to take it out of removal mode.

Aeotec* Micro Switch G2 DSC26 / DCS18

Factory Reset

  1. Press and hold the button on the Micro Switch G2 for 20 seconds and then release it.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. If the Micro Switch G2 is installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  3. If the Micro Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. If the Micro Switch G2 is installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  4. If the Micro Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Aeotec* Minimote DSA03202

Factory Reset

  1. Pull down the panel on the  Minimote
  2. Press and hold the bottom 2 buttons down. The Red and Blue LED will alternate faster and faster.
  3. When both Red and Blue LED become solid, you may let go.

Include a device from the Z-Wave Network

  1. Tap the Inclusion (+) button, LED should be blinking blue
  2. Tap the button on the device you want to add
  3. After the LED stops flashing rapidly, tap any button to get out of inclusion mode

Exclusion a device from the Z-Wave Network

  1. Tap the Exclusion (-) button, LED should blink red
  2. Tap button on the device you want to remove
  3. After LED stops flashing rapidly, tap any button to get out of the exclusion mode

Aeotec* Multisensor Gen5 ZW074

Factory Reset

  1. Press and hold Multisensor Gen5 Action button (For 20 seconds)
  2. The LED of the Multisensor Gen5 will flash faster and faster. At 20 seconds, the LED should become solid for 1-2 seconds to confirm factory reset.
  3. Release the Multisensor Gen5 Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Z-Wave Button on your MultiSensor.
  3. You can test if your MultiSensor has been successfully synced with your Z-Wave network by pressing its Z-Wave Button. If you press the button and your sensor’s LED illuminates for a few seconds, then syncing has been successful.
  4. If the LED blinks when the button is pressed, the syncing has been unsuccessful and you should repeat the above steps.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on your MultiSensor.
  4. If your MultiSensor has been successfully removed from your network, its LED will blink when you press the Z-wave Button.
  5. If the removal was unsuccessful, the LED will stay solid for a few seconds when you press the Z-wave Button.

Aeotec* Multisensor 6 ZW100

Factory Reset

  1. Press the Action Button on your MultiSensor. The LED on Multisensor will blink red then change into a colorful gradient.
  2. If your MultiSensor has been successfully removed from your network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will blink.
  3. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your MultiSensor. The LED on Multisensor will blink Green rapidly, followed by a solid Green LED for 1 second for a successful inclusion, or a solid red LED for 1 second for a failed inclusion.
  3. You can test if your MultiSensor has been successfully included into your Z-Wave network by pressing its Action Button. If you press the button and your sensor's green LED is solid for a few seconds, then inclusion has been successful.
  4. If the green LED blinks when the button is pressed, the inclusion has been unsuccessful and you should repeat the steps from step 1.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your MultiSensor. The LED on Multisensor will blink red then change into a colorful gradient.
  4. If your MultiSensor has been successfully removed from your network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will blink.
  5. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button.

Aeotec* NanoMote One ZWA004

Factory Reset

  1. Press and hold the NanoMote button for 20 seconds.
  2. The LED will change from: Orange > Green > Red > Pink > Red
  3. Release the button on the second Red LED status. It will remain red for 2 seconds
  4. Tap button again while second Red LED is illuminated (you'll have 2 seconds to do so).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Double click the NanoMote button, the LED will blink rapidly with a white color.
  3. If your NanoMote has been successfully added to your Z-Wave  network, its white LED will be solid for about 10 seconds, then flash green to indicate it is awake.
  4. If the adding was unsuccessful and the red LED will be solid for 2 seconds and then off, repeat the above steps.
    • If your NanoMote does not go to sleep on its own, press and hold for 2 seconds (or until LED turns orange) then release its button to put your NanoMote to sleep.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Double click the NanoMote button, the LED will become a solid green color.
  4. If your NanoMote has been removed from your Z-Wave network, its LED will begin cycling through a rainbow of colors.

Aeotec* NanoMote Quad ZWA003

Factory Reset

  1. Press and hold the NanoMote button for 20 seconds.
  2. The LED will change from: Orange > Green > Red > Pink > Red
  3. Release the button on the second Red LED status. It will remain red for 2 seconds
  4. Tap button again while second Red LED is illuminated (you'll have 2 seconds to do so).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Double click the NanoMote button (can be any button), the LED will blink rapidly with a white color.
  3. If your NanoMote has been successfully added to your Z-Wave  network, its white LED will be solid for about 10 seconds, then flash green to indicate it is awake. If the adding was unsuccessful and the red LED will be solid for 2 seconds and then off, repeat the above steps.
    • If your NanoMote does not go to sleep on its own, press and hold for 2 seconds (or until LED turns orange) then release its button to put your NanoMote to sleep.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Double click the NanoMote button, the LED will become a solid green color.
  4. If your NanoMote has been removed from your Z-Wave network, its LED will begin cycling through a rainbow of colors.

Aeotec* Nano Dimmer ZW111

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on the Nano Dimmer, the green LED (basic secure indication) will blink to indicate the Nano Dimmer is entering into pairing mode.
  3. If the Nano Dimmer has been successfully added to your Z-Wave network, its RGB LED will be solid.
  4. If the pairing was unsuccessful, the red LED will be on for 2 seconds and then remain a colorful gradient, repeat the steps above.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Aeotec* Nano Switch ZW116 (with energy reading)

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once on the Nano Switch.
  3. If inclusion is successful, the green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to a colorful gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Aeotec* Nano Switch ZW139 (without energy reading)

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once on the Nano Switch.
  3. If inclusion is successful, the green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the red LED will be on for 2 seconds and then return to a colorful gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Aeotec* Range Extender DSD37 (Aeon Labs DSD37 Z-Wave Network Repeater)

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the Range Extender to a default state.

Join the Z-Wave Network (Z-Stick)

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Z-Stick.
  3. If Range Extender has been successfully linked to your Z-Wave network, its Network LED will no longer blink.
  4. If the linking was unsuccessful and the Network LED continues to blink repeat the above steps.
  5. Press the Action Button on the Z-Stick to take it out of installation mode.

Join the Z-Wave Network (Minimote)

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Include button on your Minimote.
  3. If the Range Extender has been successfully linked to your Z-Wave network, its Network LED will no longer blink.
  4. If the linking was unsuccessful and the Network LED continues to blink repeat the above steps.
  5. Press any button on your Minimote to take it out of inclusion mode.

Exclusion from the Z-Wave Network (Z-Stick)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. If your Range Extender has been successfully removed from your network, its Network LED will blink.
  5. If the removal was unsuccessful, the Network LED will not blink.
  6. Press the Action Button on the Z-Stick to take it out of removal mode.

Exclusion from the Z-Wave Network (Minimote)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Remove Button on your Minimote.
  4. If your Range Extender has been successfully removed from your network, its Network LED will blink.
  5. If the removal was unsuccessful, the Network LED will not blink.
  6. Press any button on your Minimote to take it out of removal mode.

Aeotec* Range Extender 6 ZW117

Factory Reset

  1. Press and hold the Z-Wave Button for 20 seconds to completely factory reset your Range Extender 6.
  2. During the time that you are holding your Range Extender 6 action button down, the LED will blink through these colors: Yellow (at 2 seconds) > Purple (at 5 seconds) > Red for 8 seconds (initializing factory reset) > Green for 20 seconds (factory reset complete) > Rainbow LED (ready to be paired to a new gateway).
  3. You may let go when the LED turns green. Your Range Extender will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Z-Wave Button on your Range Extender and quickly release the button (should only be a quick tap action on the button) and its LED will blink green rapidly (green indicates insecure pairing, if you want to pair securely, please refer to Enabling Security Encryption section in the Advanced Function section).
  3. If Range Extender has been successfully added  to your Z-Wave network, its LED will be solid for 2 seconds then turn off. If the adding was unsuccessful, the red LED will be on for 2 seconds and then remain colorful gradient status, repeat the steps above.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on your Range  Extender.
  4. If Range Extender has been successfully removed  from your network, its RGB LED will remain colorful gradient status.
  5. If the removal was unsuccessful, the RGB LED will still be solid, repeat the steps above.

Aeotec* Recessed Door Sensor Gen5 ZW089

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it. Your sensor will now be reset to its original settings

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Sensor. If your Sensor has been successfully linked to your network, its LED will become solid for 2 seconds then disappear.
  3. If linking was unsuccessful, the LED will continue to blink if you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor. If your switch has been successfully unlinked to your network, its LED will begin to blink for a short time.
  4. If linking was unsuccessful, the LED will return to its last state. Tap the button to confirm if it has been unpaired, if unpaired successfully, the LED will blink when tapped.

Aeotec* Siren ZW080

Factory Reset

  1. Press and hold the Action button for 20 seconds
  2. At 8 seconds, the Siren will sound for 1 second, then stop
  3. The LED will continue to blink faster and faster and then will then turn solid for 2 seconds to indicate a successful factory reset
  4. You may let go of its Action button, and the Siren Gen5 factory reset is complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Siren Gen5, and its LED will blink rapidly to indicate that it is communicating.
  3. If your Siren has been successfully linked to your network, its LED will become solid for 2 seconds, then stop.
  4. If linking was unsuccessful, the LED will blink when you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Siren.
  4. If your Siren has been successfully unlinked from your network, its LED will begin to blink.

Aeotec* Smart Switch 6 ZW096

Factory Reset

  1. Press and hold the Action Button for 20 seconds.
  2. The LED will change between these colors: Yellow > Purple > Red (blinks faster and faster) > Green (Successful indication of factory reset) > Rainbow LED (waiting to pair to new network).
  3. When the LED changes to Green state, you may let go of the action button.
  4. When the LED changes to a rainbow LED state, it will indicate that it is ready to pair to a new network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your Switch once and the LED will flash a green LED.
  3. If your switch has been successfully linked to your network, its LED will become solid green for 2 seconds.
  4. If linking was unsuccessful, the LED will return to a rainbow gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Switch.
  4. If your switch has been successfully unlinked from your network, its LED will become a rainbow gradient.
  5. If linking was unsuccessful, the LED will become green or purple depending on how your LED mode is set.

Aeotec* TriSensor ZWA005

Factory Reset

  1. Press and hold the Action Button for 15 seconds.
  2. The red LED flashes to confirm a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button on your sensor once.
  3. The LED will turn yellow LED for 10 seconds.
  4. If the LED flashes green twice, then the sensor has successfully joined the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your sensor.
  4. The LED will turn purple for 2 seconds, and then white when exclusion is successful.

Aeotec* WallMote Quad ZW129

Factory Reset

  1. Press and hold the Action button (20 seconds).
  2. The LED should blink between green, purple, then red which will flash rapidly until a green LED becomes solid for 2 seconds to indicate a successful factory reset.
  3. Let go of the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once on WallMote Quad to include it.
  3. The green LED will be on for 2 seconds and then the orange LED will fast blink for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your WallMote Quad.
  4. If your WallMote Quad is successfully removed from the Z-Wave network, the LED will become a colorful gradient for a few seconds and then turn off. If the removal was unsuccessful, the red LED will be solid for 2 seconds and then turn off, repeat the above steps.

Aeotec* WallMote Quad ZW130

Factory Reset

  1. Press and hold the Action button (20 seconds).
  2. The LED should blink between green, purple, then red which will flash rapidly until a green LED becomes solid for 2 seconds to indicate a successful factory reset.
  3. Let go of the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Action Button once on WallMote Quad to include it.
  3. The green LED will be on for 2 seconds and then the orange LED will fast blink for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your WallMote Quad.
  4. If your WallMote Quad is successfully removed from the Z-Wave network, the LED will become a colorful gradient for a few seconds and then turn off. If the removal was unsuccessful, the red LED will be solid for 2 seconds and then turn off, repeat the above steps.

August

August Smart Lock Pro

Factory Reset

  1. You must have your lock first connected to the August App
  2. Go into Lock Settings > Z-Wave Settings. If you are connected, you will see Remove Z-Wave Device. Select Remove Z-Wave Device and on the next page you will see two options:
    • My Hub is in Exclusion Mode - use this mode when you have working hub and can properly disconnect.
    • My Hub is No Longer Working - use this mode to RESET the Device.
  3. Select the My Hub is No Longer Working option and then select Reset Z-Wave Device.

Join the Z-Wave Network

  1. You must have your lock first connected to the August App
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. On the August App, go into Lock Settings and door for Z-Wave Settings.
  4. The first time the screen will state that "The Lock is not connected to a Z-Wave Network". Select "Add to a Z-Wave Network".
  5. Follow the instructions to put the lock into Learn Mode.

Exclusion from the Z-Wave Network

  1. You must have your lock first connected to the August App
  2. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Go into Lock Settings > Z-Wave Settings. If you are connected, you will see Remove Z-Wave Device.
  5. Select Remove Z-Wave Device and on the next page you will see two options.
    • My Hub is in Exclusion Mode - Use this mode when you have a working hub and can properly disconnect.
    • My Hub is No Longer Working - Use this mode to RESET the Device.
  6. Select the My Hub is in Exclusion Mode option to exclude the lock from the Z-Wave network.

BeSense

BeSense Zwave PLUS Ceiling PIR Sensor IX32

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

BeSense Zwave Plus Window/Door Sensor IM20

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

BeSense Zwave PIR Sensor IX30

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

Centralite

Centralite Pearl Zigbee Thermostat 3000-G

Factory Reset

  1. Enter Programming Mode, navigate to Menu ID “17”, press HOLD, then navigate to option “11”, then press HOLD again.
  2. The device will then factory reset itself and begin looking for an open network to join.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Enter Programming Mode, navigate to Menu ID “17”, press HOLD, then navigate to option “11”, then press HOLD again.
  3. The device will then factory reset itself and begin looking for an open network to join.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 3-Series Smart Outlet 3200-G

Factory Reset

  1. Unplug any devices from the module and unplug from the wall.
  2. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Unplug any devices from the module and unplug from the wall.
  3. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 3-Series Zigbee Door & Window Sensor 3300-G

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 3-Series Zigbee Motion Sensor 3305-G

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 3-Series Zigbee Micro Door Sensor 3323-G

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 3-Series Zigbee Micro Motion Sensor 3328-G

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite 4-Series Zigbee Smart Outlet 4200-C

Factory Reset

  1. Unplug any devices from the module and unplug from the wall.
  2. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Unplug any devices from the module and unplug from the wall.
  3. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.
  4. After the Smart Outlet has successfully joined a ZigBee network, the status LED will turn solid green

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

CREE

CREE Connected LED Bulbs

Factory Reset

  1. Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb
  2. The bulb will blink once, indicating it is reset and ready for pairing

Factory Reset (Alternate Methods)

  • Method 1 - Use a Philips Hue Dimmer Switch
  1. Turn the bulb on (ensure there are no others in the same lamp, as they could be reset too, using this method).
  2. Hold the remote within 4 inches of the bulb.
  3. Press and hold the 1st (On / I in some countries) and the 4th (Off / O in some countries) buttons simultaneously for about 10 seconds, until the bulb starts blinking on and off.
  4. If the bulb stopped blinking (it will normally turn fully on again after reset) and the green LED on the remote (top left of the remote) blinked green - your bulb is reset.
    • This method can be used for nearly ALL ZigBee LL bulbs.
  • Method 2 - Use a Lutron LZL-4B Connected Bulb Remote (Discontinued Product)
  1. Hold the remote within 4 inches of the bulb.
  2. Press and hold the 2nd (up arrow) and 4th (light off) buttons simultaneously.
  3. The bulb should blink on and off
  4. The green LED on the remote should come on and may blink a few times.
  5. Continue to hold both buttons on the remote until the green LED goes off completely.
    • This method can be used for nearly ALL ZigBee LL bulbs.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb
  3. The bulb will blink once, indicating it is reset and ready for pairing

Join the Zigbee Network (Alternate Methods)

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. See Factory Reset (Alternate Methods) above to reset the bulb and put it into pairing mode.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Dome

Dome Door / Window Sensor DMWD1

Factory Reset

  1. Open the Cover and make sure the Door/Window Sensor is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator blinks once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the Cover of the Door/Window Sensor.
  3. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the Cover of the Door/Window Sensor.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful exclusion from the Z-Wave network.

Dome Door / Window Sensor Pro DMDP1

Factory Reset

  1. Remove the Sensor Cover and confirm that your Door/Window Sensor is powered up.
  2. Wait for 5 seconds.
  3. Move the Magnet and Sensor Base in and out of the closed position 6 times.
  4. The LED indicator will light up red for five seconds when reset successfully. The Door/Window Sensor’s memory will be erased to factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the Sensor Cover and the LED indicator will start blinking yellow.
  3. Press the Button quickly 3 times in a row.
  4. The device will enter inclusion mode for two minutes and the LED indicator will alternate between green and red. After successful inclusion, the LED Indicator will flash green three times then blink red until the cover is replaced.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the SENSOR COVER and the LED indicator will start blinking red.
  4. Press the Button quickly 3 times in a row.
  5. The LED Indicator will flash green three times indicating successful exclusion from the Z-Wave network. It will continue flashing red (indicating tamper) until the cover is replaced.

Dome Leak Sensor DMWS1

Factory Reset

  1. Open the Back Plate and make sure the Leak Sensor is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator blinks once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the cover of the Leak Sensor by twisting it apart.
  3. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the cover of the Leak Sensor by twisting it apart.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful exclusion from the Z-Wave network.

Dome Leak Sensor DMMS1

Factory Reset

  1. Remove the Cover and make sure the Motion Detector is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator blinks once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the cover of the Motion Detector by twisting it apart.
  3. Press the Connect Button quickly 3 times in a row.
  4. The LED indicator will flash five times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the cover of the Motion Detector by twisting it apart and make sure the Motion Detector is powered.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful exclusion from the Z-Wave network.

Dome Mouser DMMZ1

Factory Reset

  1. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  2. Press and hold the CONNECT BUTTON for at least 10 seconds then release.
  3. A flashing LED indicator indicates a successful factory reset. The Mousers memory will be erased to factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  3. Press the CONNECT BUTTON quickly 3 times in a row.
  4. The LED indicator will flash five times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  4. Press the CONNECT BUTTON quickly 3 times in a row. The LED indicator will flash five times indicating successful exclusion from the Z-Wave network.

Dome On/Off Plug-In Switch DMOF1

Factory Reset

  1. Plug in the On/Off Plug-In Switch.
  2. Hold the Connect Button for 10 seconds until the LED Indicator blinks once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Plug in the On/Off Plug-In Switch within range of your Z-Wave Controller.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash five times indicating successful exclusion from the Z-Wave network.

Dome Range Extender DMEX1

Factory Reset

  1. Hold the Button for 10 seconds until the LED blinks 10 times, then release the button

Join the Z-Wave Network

  1. For proper inclusion, install the Range Extender in the final location where it will be used.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Plug the Range Extender into an outlet or use a micro USB (not included) to power it. The LED will flash 5 times indicating successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Button quickly 3 times in a row The LED will flash 5 times indicating successful exclusion.

Dome Siren DMS01

Factory Reset

  1. Open the Back Plate and make sure the Siren is powered.
  2. Hold the Connect Button for 10 seconds until the LED Ring blinks once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the Back Plate of the Siren.
  3. Press the Connect Button quickly 3 times in a row. The LED Ring will flash five times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the Back Plate of the Siren.
  4. Press the Connect Button quickly 3 times in a row. The LED Ring will flash five times indicating successful exclusion from the Z-Wave network.

Dome Water Main Shut-Off DMWV1

Factory Reset

  1. Press and hold the open/close button for at least 10 seconds then release.
  2. The Shut-Off’s memory will be erased to factory settings. A flashing light indicates a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Make sure the Water Main Shut-Off is powered on, then press the “open/close” button quickly 3 times in a row. The LED will stop blinking and stay on continuously upon successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. When prompted, press the “open/close” button on the Shut-Off quickly 3 times in a row.

Dragon Tech

Dragon Tech Plug in Z-Wave Plus Dimmer Switch PD-100

Factory Reset

  1. Unplug the PD-100 and anything the is plugged into it.
  2. Press and hold the button on the front of the PD-100
  3. Plug the PD-100 in while still pressing the button
  4. After 3 seconds, release the button. If the button blinks, the PD-100 has been successfully reset. If not, repeat the steps to factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the button on the front of the PD-100

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the button on the front of the PD-100

Eaton (Cooper Wiring Devices)

Z-Wave Wireless Dimmer RF9540

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the device switch one time to exclude it from the network. The LED will start blinking, indicating the dimmer has been successfully excluded from the Z-Wave network.

Join the Z-Wave Network

  1. Cooper Wiring Devices Z-Wave device has a blue LED, which will blink when the device is not included in a Z-Wave network. The LED stops blinking when the device is in a network.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the device switch one time to include it in the network. The LED will stop blinking, indicating the dimmer has been successfully included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the device switch one time to exclude it from the network. The LED will start blinking, indicating the dimmer has been successfully excluded from the Z-Wave network.

Ecolink

Ecolink Door / Window Sensor DWZWAVE2.5-ECO

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. When the exclusion process is complete, the LED on the sensor will be solid blue, then go out.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Remove the battery for at least 5 seconds, then reinstall it.
  3. When the inclusion process is complete, the LED on the sensor will be solid blue, then go out.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. When the exclusion process is complete, the LED on the sensor will be solid blue, then go out.

Fibaro

Fibaro Wall Plug FGWPB / FGWPE

Factory Reset

  1. Press and hold the button located on the side.
  2. The device will cycle through GREEN, then VIOLET, and finally YELLOW for device reset.
  3. Release the button.
  4. Press the button again to confirm the selection and factory reset the device.

Join the Z-Wave Network

  1. Plug the device into a socket nearby the main Z-Wave controller.
  2. The LED frame will glow red signaling not being added (reset or remove the device otherwise).
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  4. Quickly, triple click the button on the side of the device.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Plug the device into a socket nearby the main Z-Wave controller.
  3. The LED frame will glow green signaling being added (removing is not necessary otherwise).
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  5. Quickly, triple click the button on the side of the device.

First Alert

First Alert ZCOMBO-G

Factory Reset

  1. Power up the device with the test button held down for 10+ seconds
  2. The device will reset all Z-Wave settings and leave the network. NOTE: The device will not remain awake after resetting and will go into standby mode.

Join the Z-Wave Network

  1. Slide battery door open and insert batteries.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will remain awake for 30 seconds on inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Slide battery door open, then remove and re-insert batteries.
  4. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will be excluded from the network.

GE/Jasco

GE/Jasco Plug-in Dimmer 12718

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco Plug-in Switch 12719

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco Outdoor Plug-in Switch 12720

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco In-Wall Outlet 12721

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco In-Wall Switch 12722

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.

GE/Jasco In-Wall Dimmer 12724

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.

GE/Jasco In-Wall Toggle Switch 12727

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press up and release the toggle switch to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press up and release the toggle switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press up and release the toggle switch to exclude it from the network.

GE/Jasco In-Wall Toggle Dimmer 12729

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press up and release the toggle switch to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press up and release the toggle switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press up and release the toggle switch to exclude it from the network.

GE/Jasco In-Wall Fan Control 12730

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless fan control rocker to exclude it from the network.

GE/Jasco Z-Wave Plus Plug-In Outdoor Switch 14284

Factory Reset

  1. Unplug the switch from the outlet
  2. Press and hold the manual/program button on the switch for at least three seconds while you plug the switch into an outlet

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco Z-Wave Plus In-Wall Fan Control 14287

Factory Reset

  1. Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart fan control rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

GE/Jasco Z-Wave Plus In-Wall Tamper Resistant Outlet 14288

Factory Reset

  1. Press the manual/program button 3 times, then press and hold the button for at least 3 seconds. The LED will blink 5 times to confirm.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco Z-Wave Plus In-Wall Switch 14291

Factory Reset

  1. Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart switch rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart switch rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

GE/Jasco Z-Wave Plus In-Wall Dimmer 14294

Factory Reset

  1. Quickly press ON (Top) button three (3) times then immediately press the OFF (Bottom) button three (3) times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

GE/Jasco Z-Wave Plus Plug-in Dimmer 28167

Factory Reset

  1. If plugged in, unplug the Dimmer from the receptacle.
  2. Press and hold the top button for at least 3 seconds while you plug the dimmer into a receptacle.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GE/Jasco Z-Wave Plus Plug-in Dimmer 28169

Factory Reset

  1. If plugged in, unplug the Dimmer from the receptacle.
  2. Press and hold the top button for at least 3 seconds while you plug the dimmer into a receptacle.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

GoControl

GoControl GD00Z Series Garage Door Controllers

Includes Linear GD00Z-2, GoControl GD00Z-4, Linear GD00Z-5, ADT GD00Z-6, GoControl GD00Z-7 and NuTone ND00Z

Factory Reset

  1. Reset the controller by pressing the Link button 5 times.
  2. A quick beep followed by a longer beep will indicate proper reset of the GD00Z series or ND00Z.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the Link button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the Link button.

GoControl WADWAZ-1 Door / Window Sensor

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

Join the Z-Wave Network

  1. Unscrew the screw fastening the rear cover and slide the rear cover down
  2. Insert a CR123A battery into the battery compartment and LED will start to flash slowly, which means the sensor has not yet performed inclusion with the controller.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  4. Once Hubitat Elevation™ discovers the device, the LED will stop blinking. If the LED does not stop blinking and is not discovered by your hub, relocate the WADWAZ-1 to within 100 feet (line of sight) of a Z-Wave repeater or your hub and restart Z-Wave pairing.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

Kwikset

Kwikset 910 & 914 Z-Wave Lock

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
  3. Press the Program button once more. When the LED flashes green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Z-Wave Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your Z-Wave controller
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press button A on the lock one time to include it. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.
  4. If Inclusion is unsuccessful, go to the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  5. Press button A on the lock one time. Once the lock is fully Excluded from the system, repeat the Inclusion process.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press button A on the lock one time. Once the lock is fully Excluded from the system. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.

Kwikset 910 & 914 Zigbee Lock

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
  3. Press the Program button once more. When the LED flashes green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Zigbee Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your Z-Wave controller
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press button A on the lock 4 times to pair it. The controller and lock must remain stationary for a total of 60 seconds during the pairing process.
    • If pairing is unsuccessful ZigBee Inclusion: Press button B on the lock 9 times. Repeat the pairing process.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press button B on the lock 9 times.

Lutron

Lutron VRCS4

Factory Reset

  1. On the 4-Scene controller, press and hold buttons 1 and 3.
  2. Wait approximately 5 seconds until the LED turns amber and then solid red.
  3. Release the buttons and the 4-Scene controller will be reset. NOTE: Factory reset does not exclude the device from any previous networks it has joined. The exclusion process must still be performed separately.

Join the Z-Wave Network

Leaving the Z-Wave Network


Radio Thermostat Company of America

Radio Thermostat Company of America CT-101

Factory Reset

  1. The thermostat must be in OFF mode.
  2. Wait until the radio wave icons on the left side of the screen stop blinking then touch the screen once to turn on the back light and then hold the center of the screen for about 8 seconds until the thermostat beeps.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  3. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will blink.
  4. When a device has joined a network the LINK icon will appear under the radio tower.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  4. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will blink.
  5. When a device has excluded from the network, the LINK icon will disappear under the radio tower.

Schlage

Schlage BE469 Lock

Factory Reset

  1. Disconnect the batteries
  2. Press and hold the outside Schlage button
  3. While holding the outside Schlage button, then reconnect the batteries.
  4. Release the Outside Schlage Button. NOTE: If you are moving the lock to a new door, install the lock on that door before continuing.
  5. To check that the lock was reset, press the outside Schlage button and enter one of the Default User Codes.
  6. If the reset was successful, the lock will perform a setup routine. Wait until the bolt stops moving. The reset and setup are complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Schlage button
  3. Enter the 6 digit programming code
  4. Press 0
  5. A indicates the lock successfully joined the Z-Wave network, while an X indicates that it did not successfully join the network

Verify Z-Wave connection status from the lock

  1. Remove the battery cover
  2. Disconnect the battery connector
  3. While watching the inside Schlage button, reconnect the battery connector
  4. The inside Schlage button will blink if the lock is enrolled

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Schlage button
  4. Enter the 6 digit programming code
  5. Press 0
  6. A indicates the lock was successfully excluded the Z-Wave network, while an X indicates that it did not successfully leave the network

Utilitech

Utilitech Indoor Siren TSE07

Factory Reset

  1. Remove the battery cover
  2. Press the pairing button in between the batteries 8 times, one second apart

Join the Z-Wave Network

  1. Remove the battery cover
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press the paring button once

Exclusion from the Z-Wave Network

  1. Remove the battery cover
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the paring button once

*Note: Aeotec was formerly known as Aeon Labs.