Join and Reset Instructions

From Hubitat Documentation
Revision as of 19:08, 1 May 2019 by Doug (talk | contribs) (Added Schlage BE469)
Jump to: navigation, search

Schlage BE469 Lock

Factory Reset

  1. Disconnect the batteries.
  2. Press and hold the Outside Schlage Button.
  3. While holding the Outside Schlage Button, then reconnect the batteries.
  4. Release the Outside Schlage Button. NOTE: If you are moving the lock to a new door, install the lock on that door before continuing.
  5. To check that the lock was reset, press the Outside Schlage Button and enter one of the Default User Codes.
  6. If the reset was successful, the lock will perform a setup routine. Wait until the bolt stops moving. The reset and setup are complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select "Z-Wave", then "Start Z-Wave Pairing" on the Device Discovery page.
  2. Press the Schlage button
  3. Enter the 6 digit programming code
  4. Press 0
  5. A indicates the lock successfully joined the Z-Wave network, while an X indicates that it did not successfully join the network

Verify Z-Wave connection status from the lock

  1. Remove the battery cover
  2. Disconnect the battery connector
  3. While watching the inside Schlage button, reconnect the battery connector
  4. The inside Schlage button will blink if the lock is enrolled

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select "Z-Wave", then "Start Z-Wave Exclusion" on the Device Discovery page.
  2. Press the Schlage button
  3. Enter the 6 digit programming code
  4. Press 0
  5. A indicates the lock was successfully excluded the Z-Wave network, while an X indicates that it did not successfully leave the network

GE Outdoor Switch

Factory Reset

  1. Unplug switch from outlet
  2. Press and hold the manual/program button on the switch for at least three seconds while you plug the switch into an outlet

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select "Z-Wave", then "Start Z-Wave Pairing" on the Device Discovery page.
  2. Press the manual/program button once

Exclusion from the Z-Wave Network

  1. From the device's details page, click "Remove Device", then "Remove"
  2. Press the manual/program button on the switch once