Join and Reset Instructions

From Hubitat Documentation
Revision as of 16:16, 13 May 2019 by Doug (talk | contribs) (Added Radio Thermostat Company of America CT-101)
Jump to: navigation, search

Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into Paring Mode using the manufacturer's instructions, Z-Wave devices must be Excluded from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation™, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a General Exclusion in your Hubitat Elevation™ hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show Unknown Device Excluded in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See How to Build a Solid Z-Wave Mesh for further detail on methods of Exclusion.

Schlage BE469 Lock

Factory Reset

  1. Disconnect the batteries
  2. Press and hold the outside Schlage button
  3. While holding the outside Schlage button, then reconnect the batteries.
  4. Release the Outside Schlage Button. NOTE: If you are moving the lock to a new door, install the lock on that door before continuing.
  5. To check that the lock was reset, press the outside Schlage button and enter one of the Default User Codes.
  6. If the reset was successful, the lock will perform a setup routine. Wait until the bolt stops moving. The reset and setup are complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the Schlage button
  3. Enter the 6 digit programming code
  4. Press 0
  5. A indicates the lock successfully joined the Z-Wave network, while an X indicates that it did not successfully join the network

Verify Z-Wave connection status from the lock

  1. Remove the battery cover
  2. Disconnect the battery connector
  3. While watching the inside Schlage button, reconnect the battery connector
  4. The inside Schlage button will blink if the lock is enrolled

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the Schlage button
  3. Enter the 6 digit programming code
  4. Press 0
  5. A indicates the lock was successfully excluded the Z-Wave network, while an X indicates that it did not successfully leave the network

Kwikset 910 & 914 Z-Wave Lock

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
  3. Press the Program button once more. When the LED flashes green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Z-Wave Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your Z-Wave controller
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press button A on the lock one time to include it. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.
  4. If Inclusion is unsuccessful, go to the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  5. Press button A on the lock one time. Once the lock is fully Excluded from the system, repeat the Inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press button A on the lock one time. Once the lock is fully Excluded from the system. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.

Kwikset 910 & 914 Zigbee Lock

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes red.
  3. Press the Program button once more. When the LED flashes green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Zigbee Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your Z-Wave controller
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press button A on the lock 4 times to pair it. The controller and lock must remain stationary for a total of 60 seconds during the pairing process.
    • If pairing is unsuccessful ZigBee Inclusion: Press button B on the lock 9 times. Repeat the pairing process.

Leaving the Zigbee Network

  1. From the device's details page, click Remove Device, then Remove.
  2. Press button B on the lock 9 times.

GoControl GD00Z Series Garage Door Controllers

Includes Linear GD00Z-2, GoControl GD00Z-4, Linear GD00Z-5, ADT GD00Z-6, GoControl GD00Z-7 and NuTone ND00Z

Factory Reset

  1. Reset the controller by pressing the Link button 5 times.
  2. A quick beep followed by a longer beep will indicate proper reset of the GD00Z series or ND00Z.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press and release the Link button.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the Link button.

GoControl WADWAZ-1 Door / Window Sensor

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

Join the Z-Wave Network

  1. Unscrew the screw fastening the rear cover and slide the rear cover down
  2. Insert a CR123A battery into the battery compartment and LED will start to flash slowly, which means the sensor has not yet performed inclusion with the controller.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  4. Once Hubitat Elevation™ discovers the device, the LED will stop blinking. If the LED does not stop blinking and is not discovered by your hub, relocate the WADWAZ-1 to within 100 feet (line of sight) of a Z-Wave repeater or your hub and restart Z-Wave pairing.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

First Alert ZCOMBO-G

Factory Reset

  1. Power up the device with the test button held down for 10+ seconds
  2. The device will reset all Z-Wave settings and leave the network. NOTE: The device will not remain awake after resetting and will go into standby mode.

Join the Z-Wave Network

  1. Slide battery door open and insert batteries.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will remain awake for 30 seconds on inclusion.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Slide battery door open, then remove and re-insert batteries.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will be excluded from the network.

Radio Thermostat Company of America CT-101

Factory Reset

  1. The thermostat must be in OFF mode.
  2. Wait until the radio wave icons on the left side of the screen stop blinking then touch the screen once to turn on the back light and then hold the center of the screen for about 8 seconds until the thermostat beeps.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  3. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will blink.
  4. When a device has joined a network the LINK icon will appear under the radio tower.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  3. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will blink.
  4. When a device has excluded from the network, the LINK icon will disappear under the radio tower.

GE Outdoor Switch

Factory Reset

  1. Unplug switch from outlet
  2. Press and hold the manual/program button on the switch for at least three seconds while you plug the switch into an outlet

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
  2. Press the manual/program button once

Exclusion from the Z-Wave Network

  1. From the device's details page, click Remove Device, then Remove
  2. Press the manual/program button on the switch once
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.