Difference between revisions of "Join and Reset Instructions v1"

From Hubitat Documentation
Jump to: navigation, search
(Created page with "Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and p...")
 
Line 1: Line 1:
 
Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into '''Paring Mode''' using the manufacturer's instructions, Z-Wave devices must be '''Excluded''' from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation™, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a '''General Exclusion''' in your Hubitat Elevation™ hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show '''Unknown Device Excluded''' in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See [[How to Build a Solid Z-Wave Mesh]] for further detail on methods of Exclusion.
 
Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into '''Paring Mode''' using the manufacturer's instructions, Z-Wave devices must be '''Excluded''' from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation™, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a '''General Exclusion''' in your Hubitat Elevation™ hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show '''Unknown Device Excluded''' in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See [[How to Build a Solid Z-Wave Mesh]] for further detail on methods of Exclusion.
  
== BOSCH ==
+
=='''BOSCH'''==
 
{| class="wikitable sortable"
 
{| class="wikitable sortable"
|'''BOSCH'''
+
|<div style="text-align: center;">Brand</div>
|'''PIR Motion Detector'''
+
|<div style="text-align: center;">Device</div>
|'''ISW-ZPR1-WP13'''
+
|<div style="text-align: center;">Product Number</div>
|'''Zigbee'''
+
|<div style="text-align: center;">Device Type</div>
|}
+
|<div style="text-align: center;">Protocol</div>
'''Factory Reset'''
+
|-
 +
|<div style="text-align: center;">'''<big>BOSCH</big>'''</div>
 +
|<div style="text-align: center;">'''<big>PIR Motion Detector</big>'''</div>
 +
|<div style="text-align: center;">'''<big>ISW-ZPR1-WP13</big>'''</div>
 +
|<div style="text-align: center;">'''<big>Motion Detector</big>'''</div>
 +
|<div style="text-align: center;">'''<big>Zigbee</big>'''</div>
 +
|}'''Factory Reset'''
  
# Remove the cover by rotating it counterclockwise
+
#Unlock the battery cover and slide it upwards to remove.
# Press and hold the Connect button for 5 seconds
+
#Press upward on the tamper switch located in-between the batteries and keep it engaged while you '''remove both batteries'''.
# After the button is released, the LED will blink quickly for a few seconds, go dark for a few seconds, then blink slowly to indicate it is in pairing mode.
+
#Wait at least 4 seconds, but do not release the tamper switch.
#* Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.
+
#Keep the tamper switch engaged while you reinsert both batteries.  
  
 
'''Join the Zigbee Network'''
 
'''Join the Zigbee Network'''
  
# Remove the cover by rotating it counterclockwise
+
#Unlock the battery cover and slide it upwards to remove.
# From the Hubitat Web Interface home page, select '''Z-Wave''', then '''Start Z-Wave Pairing''' on the '''Device Discovery''' page.
+
#From the Hubitat Web Interface home page, select '''Z-Wave''', then '''Start Z-Wave Pairing''' on the '''Device Discovery''' page.
#* See Discovering your devices for detail instructions.
+
#*See Discovering your devices for detail instructions.
# Press and hold the Connect button for 5 seconds
+
#Remove both batteries for at least 10 seconds.
# After the button is released, the LED will blink quickly for a few seconds, go dark for a few seconds, then blink slowly to indicate it is in pairing mode
+
#Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
 +
#The LED will begin to blink On > Off > On > Off > On > Off (5 for seconds) and will continue to blink in this cycle for up to 3 minutes
 +
#If the motion sensor does not pair with the hub in less than 3 minutes, perform another factory reset and repeat the above steps to join the Zigbee network.
  
 
'''Leaving the Zigbee Network'''
 
'''Leaving the Zigbee Network'''
  
# From the device's details page, select '''Remove Device''', then '''Remove.'''
+
#From the device's details page, select '''Remove Device''', then '''Remove.'''<hr />
 +
=='''<big>Leviton</big>'''==
 +
{| class="wikitable sortable"
 +
|<div style="text-align: center;">Brand</div>
 +
|<div style="text-align: center;">Device</div>
 +
|<div style="text-align: center;">Product Number</div>
 +
|<div style="text-align: center;">Device Type</div>
 +
|<div style="text-align: center;">Protocol</div>
 +
|-
 +
|<div style="text-align: center;">'''<big>Leviton</big>'''</div>
 +
|<div style="text-align: center;">'''<big>4-Scene Controller</big>'''</div>
 +
|<div style="text-align: center;">'''<big>VRCS4</big>'''</div>
 +
|<div style="text-align: center;">'''<big>Button Controller</big>'''</div>
 +
|<div style="text-align: center;">'''<big>Z-Wave</big>'''</div>
 +
|}'''Factory Reset'''
 +
 
 +
#On the 4-Scene controller, press and hold buttons 1 and 3.
 +
#Wait approximately 5 seconds until the LED turns amber and then solid red.
 +
#Release the buttons and the 4-Scene controller will be reset. '''NOTE: Factory reset does not exclude the device from any previous networks it has joined. The exclusion process must still be performed separately.'''
 +
 
 +
'''Join the Z-Wave Network'''
 +
 
 +
'''Leaving the Z-Wave Network'''

Revision as of 18:25, 19 May 2019

Before you can join your devices to your Hubitat Elevation™ hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into Paring Mode using the manufacturer's instructions, Z-Wave devices must be Excluded from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation™, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a General Exclusion in your Hubitat Elevation™ hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show Unknown Device Excluded in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See How to Build a Solid Z-Wave Mesh for further detail on methods of Exclusion.

BOSCH

Brand
Device
Product Number
Device Type
Protocol
BOSCH
PIR Motion Detector
ISW-ZPR1-WP13
Motion Detector
Zigbee

Factory Reset

  1. Unlock the battery cover and slide it upwards to remove.
  2. Press upward on the tamper switch located in-between the batteries and keep it engaged while you remove both batteries.
  3. Wait at least 4 seconds, but do not release the tamper switch.
  4. Keep the tamper switch engaged while you reinsert both batteries.

Join the Zigbee Network

  1. Unlock the battery cover and slide it upwards to remove.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  3. Remove both batteries for at least 10 seconds.
  4. Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
  5. The LED will begin to blink On > Off > On > Off > On > Off (5 for seconds) and will continue to blink in this cycle for up to 3 minutes
  6. If the motion sensor does not pair with the hub in less than 3 minutes, perform another factory reset and repeat the above steps to join the Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Leviton

Brand
Device
Product Number
Device Type
Protocol
Leviton
4-Scene Controller
VRCS4
Button Controller
Z-Wave

Factory Reset

  1. On the 4-Scene controller, press and hold buttons 1 and 3.
  2. Wait approximately 5 seconds until the LED turns amber and then solid red.
  3. Release the buttons and the 4-Scene controller will be reset. NOTE: Factory reset does not exclude the device from any previous networks it has joined. The exclusion process must still be performed separately.

Join the Z-Wave Network

Leaving the Z-Wave Network