Join and Reset Instructions v1

From Hubitat Documentation
Jump to: navigation, search

Before you can join your devices to your Hubitat Elevation® hub, you must first remove them from the previous hub or bridge. While Zigbee devices can simply be removed and put into Paring Mode using the manufacturer's instructions, Z-Wave™ devices must be Excluded from their previous network before joining a new one. Exclusion will happen automatically when the device is removed from Hubitat Elevation®, however it is recommend that Z-Wave devices always be factory reset as well. If a device cannot be factory reset, or is in an unknown state, then it is recommended to do a General Exclusion in your Hubitat Elevation® hub to be sure it isn't joined to the former Z-Wave mesh. Typically the same button on the device for inclusion is also used for exclusion. If Hubitat doesn't show Unknown Device Excluded in the log, then the General Exclusion has failed and the device probably won't be able to be joined. See How to Build a Solid Z-Wave Mesh for further detail on methods of Exclusion.

ADT

Brand
Device
Product Number
Device Type
Protocol
ADT (Nortek)
Water Leak Detector
10016864C
Water Sensor
Zigbee

Factory Reset

  1. Remove the cover by rotating it counterclockwise
  2. Press and hold the Connect button for 5 seconds
  3. After the button is released, the LED will flash quickly for a few seconds, go dark for a few seconds, then flash slowly to indicate it is in pairing mode.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. Remove the cover by rotating it counterclockwise
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press and hold the Connect button for 5 seconds
  4. After the button is released, the LED will flash quickly for a few seconds, go dark for a few seconds, then flash slowly to indicate it is in pairing mode

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

AduroSmart

Brand
Device
Product Number
Device Type
Protocol
AduroSmart
Door / Window Sensor
ERIA 81822
Contact Sensor
Zigbee

Factory Reset

  1. Use the provided pin to press and hold the reset button for 10 seconds.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Use the provided pin to press and hold the reset button for 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
AduroSmart
Dimmer Switch
ERIA 81825
Button Controller
Zigbee

Factory Reset

  1. Hold down the two middle buttons until the light flashes green. A red flash indicates an unsuccessful reset.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold down the off (circle) button for 10 seconds until it flashes green 3 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
AduroSmart
Motion Sensor
ERIA 81823
Motion Sensor
Zigbee

Factory Reset

  1. Use the provided pin to press and hold the reset button for 10 seconds.
    • Battery powered Zigbee devices often pair easier when their batteries are removed for 10 seconds following a factory reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Use the provided pin to press and hold the reset button for 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Aeotec (Aeon Labs)

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Doorbell Gen5
ZW056
Doorbell
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Doorbell will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow flashing as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Doorbell Gen5, and its LED will flash rapidly to indicate that it is communicating.
  3. If your Doorbell has been successfully linked to your network, its LED will become solid for 2 seconds, then stop. If linking was unsuccessful, the LED will flash when you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Doorbell.
  4. If your Doorbell has been successfully unlinked to your network, its LED will begin to flash slowly indicating it is ready to be paired to a new network.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Doorbell 6
ZW162-A
Doorbell
Z-Wave Plus

Factory Reset

  1. Press and hold the Action button for 20 seconds
  2. Within 2-5 seconds, the test doobell sound will run, then stop after 5 seconds has elapsed.
  3. From 5-10 seconds, the LED will begin to flash faster and faster still from 10-20 seconds.
  4. After 21 seconds, the LED will quickly flash 3 times, and then the LED slowly pulse up and down as you hold down the Action Button.
  5. With the LED pulsing, release the Action button, and the Doorbell 6 will be reset to factory defaults.

Join the Z-Wave Network

  1. Power Doorbell 6 through the provided power adapter.
  2. Ensure that Doorbell 6 LED is flashing slowly.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Tap the Doorbell 6 Action Button once.
  5. If Doorbell 6 has successfully paired to your Z-Wave gateway, the LED will be a solid color for 30 seconds, then turn off.
  6. If is fails to join the Z-Wave network, the LED will flash slowly.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button 6 times in 2 seconds.
  4. If your Doorbell 6 has been successfully unpaired from the Z-Wave network, its LED will begin to flash slowly, indicating it is ready to join a Z-Wave network again.
Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Door/Window Sensor 6
ZW112
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold Door Window Sensor 6 Action button
  2. Wait until the RGB LED turns into a Green Color, and then release. (LED will change from Yellow, Purple, Red, then to Green)
  3. If your MultiSensor has been successfully factory reset from its previous network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will flash. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the button on the Door Window Sensor 6
  3. The LED will flash green to indicate successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your Door Window Sensor is successfully removed from the Z-Wave network, the RGB LED will become a colorful gradient for a few seconds and then turn off. If the removing was unsuccessful, the RGB LED will be solid for 8 seconds and then turn off, repeat the above steps.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Door/Window Sensor Gen5
ZW120
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once to include the door/window sensor.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your Door Window Sensor has been successfully removed from your Z-Wave network, its Status LED will fast flash for 8 seconds and then slow flash for 3 seconds when you press the Action Button again.
  5. If the removal was unsuccessful, the Status LED will fast flash for 2 seconds and then be solid for 2 seconds when you press the Action Button, repeat the above steps.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Door/Window Sensor Gen2
DSB29
Contact Sensor
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once to include the door/window sensor.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor to exclude it from the network

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Door/Window Sensor 1E
DSB04100
Contact Sensor
Z-Wave

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the sensor to a default state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the security tamper switch located at the back of the Aeon Labs Door/Window Sensor to include it in the network
  3. The sensor will now stay awake for 10 minutes to receive network instructions. The LED on the will be flashing while awake.
    • Note: The DSB04100 sensor can only be taught to communicate to devices within its own network.
    • If the Aeon Labs Door / Window Sensor was not included in a Z-Wave network, pressing the security switch will illuminate the LED solid red on the front of the sensor for 5 seconds.
    • If the sensor was successfully included in the Z-Wave network, the LED will flash instead of staying solid.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Use an Aeon Z-Stick or Minimote to exclude the sensor from previous networks

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Garage Door Controller Gen5
ZW062
Garage Door Opener
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and release.
  2. Your Garage Door Controller will now be reset to its original settings, and the Network LED will be solid for 2 seconds and then start slow flashing to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave Button on the Garage Door Controller.
  3. The LED on Garage Door Controller will flash rapidly, followed by a solid LED for 1-2 second for a successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on the Garage Door Controller.
  4. The LED on Garage Door Controller will flash rapidly, followed by a solid LED for 1-2 second for a successful exclusion.
  5. The Network LED on the Garage Door Controller should now be flashing slowly to indicate it is ready to be paired to a new network.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Dry Contact Sensor Gen5
ZW097
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and Status LED will be solid for 2 seconds to confirm a success.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Sensor.
  3. If your Sensor has been successfully linked to your network, its LED will become solid for 2 seconds, then disappear.
  4. If linking was unsuccessful, the LED will continue to flash if you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor.
  4. If your switch has been successfully unlinked to your network, its LED will begin to flash for a short time.
  5. If unlinking was not successful, the LED will return to its last state. Tap the button to confirm if it has been unpaired, if unpaired successfully, the LED will flash when tapped.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Aeon Labs Home Energy Meter
AEDSB09104ZWUS
Energy Meter
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 10 seconds.
  2. If successful, the LED on the HEM should begin to flash slowly.

Join the Z-Wave Network

  1. Remove the screw from the back of your Reader and open the battery cover.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Action Button (small black button under the battery tray) on your reader. If your Reader has been successfully linked to your network, its light will remain solid for 1 second. If the linking was unsuccessful the light will flash after pressing your meter’s Action Button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the screw from the back of your Reader and open the battery cover.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Press the Action Button (small black button under the battery tray) on your reader. If your Reader has been successfully removed from your network, its light will flash for 1 second.
  5. If the removal was unsuccessful the light will be solid after pressing your meter’s Action Button.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Home Energy Meter Gen2 / Gen5
ZW095
Energy Meter
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 10 seconds.
  2. If successful, the LED on the HEM should begin to flash slowly.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. Press the Action Button on your HEM. If it has been successfully linked to your  network, its LED will remain illuminated. If the linking was unsuccessful, your HEM’s LED will continue to flash.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your HEM. If it has been successfully removed from your  network, its LED will flash. If the removal was unsuccessful, its LED will be solid and it will be then repeated again.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
LED Bulb Gen5
ZW098
Bulb
Z-Wave Plus

Factory Reset

  1. Removing LED Bulb from your Z-Wave network will reset LED Bulb to default factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, wait 2 seconds. Now toggle your wall switch ON. LED Bulb’s green LED will flash to indicate that it is looking for a Z-Wave network to connect to.
  3. After successfully connecting to your network, LED Bulb will illuminate. If a network connection has failed, it will remain without light.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Turn LED Bulb’s wall switch on.
  4. Toggle LED Bulb’s wall switch off, on, off, on, off, on within 2 seconds. The LED should flash orange, and if successful, the orange LED will be solid for 2 seconds before becoming a white color. LED Bulb should now be removed from your Z-Wave network.
  5. To confirm successful removal its color will change to orange for 2 seconds before changing to white. If removal was unsuccessful, LED Bulb will flash orange for 3 seconds before changing to red for 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
LED Bulb 6 Multi-Color
ZWA002
Bulb
Z-Wave Plus

Factory Reset

  1. Turn LED Bulb’s wall switch on and wait 1 second.
  2. Toggle LED Bulb's wall switch 6 times (off -> on, off -> on, off -> on, off -> on, off -> on, off -> on) between 0.5 - 2 seconds per re-power.
  3. If successful, the LED Bulb 6 Multi-Color will change to a warm white, solid yellow, then flash red -> white 3 times to indicate a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, toggle your wall switch ON. LED Bulb’s LED will turn into a solid yellow color to indicate that it is in pair mode up to 10 seconds.
  3. After successfully connecting to your network, LED Bulb will flash green -> white color for 3 seconds. If a network connection has failed, LED Bulb 6 Multi-Color will flash red -> white for 3 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle LED Bulb’s wall switch 3 times (off > on, off > on, off > on) between 0.5 - 2 seconds per cycle.
  4. LED Bulb 6 has been unpaired successfully, the LED will flash blue > white for 3 seconds.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
LED Bulb 6 Multi-White
ZWA001
Bulb
Z-Wave Plus

Factory Reset

  1. Turn LED Bulb’s wall switch on and wait 1 second.
  2. Toggle LED Bulb's wall switch 6 times (off -> on, off -> on, off -> on, off -> on, off -> on, off -> on) between 0.5 - 2 seconds per re-power.
  3. If successful, the LED Bulb 6 Multi-White will flash twice to indicate that it successfully reset itself to factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. With LED Bulb in its fitting, toggle your wall switch ON. LED Bulb’s LED will flash 2 times to indicate that it is looking for a Z-Wave network to connect to.
  3. After successfully connecting to your network, LED Bulb will flash off then on in about 0.5 second to indicate that it attempted to pair to your network. If a network connection has failed, LED Bulb 6 Multi-White will not react.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Turn LED Bulb’s wall switch on and wait 1 second.
  4. Toggle LED Bulb’s wall switch 3 times (off > on, off > on, off > on) between 0.5 - 2 seconds per cycle.
  5. LED Bulb 6 if successful will flash once, dim to 5% for 5 seconds, then increase to 100% dim level to indicate a successful unpair and factory reset.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Micro Illuminator G2
DSC19103-ZWUS
Dimmer
Z-Wave

Factory Reset

  1. Hold the Z-Wave button for 30 seconds and release it to reset the entire module including Z‐Wave to factory default settings (the LED will stay solid after holding the button for 30 seconds).

Join the Z-Wave Network

  1. Connect Micro Smart Dimmer to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Z‐Wave button.
  4. If the inclusion fails, please repeat the process from step 2.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z‐Wave button.
  4. If the exclusion fails, please repeat the process from step 2

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Micro Motor Controller
DSC14104-ZWEU/US, DSC14103-ZWAU
Motor Controller
Z-Wave

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the controller to a default state.

Join the Z-Wave Network (Z-Stick)

  1. Connect Micro Motor Controller to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. Press the Action Button on your Micro Motor Controller.
  5. If Micro Motor Controller has been successfully linked to your Z-Wave network, its Network LED will no longer flash.
  6. If the linking was unsuccessful and the Network LED continues to flash repeat the above steps.
  7. Press the Action Button on the Z-Stick to take it out of installation mode.

Join the Z-Wave Network (Minimote)

  1. Connect Micro Motor Controller to an AC‐input power source.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Include button on your Minimote.
  4. Press the Action Button on your Micro Motor Controller.
  5. If the Micro Motor Controller has been successfully linked to your Z-Wave network, its Network LED will no longer flash.
  6. If the linking was unsuccessful and the Network LED continues to flash repeat the above steps.
  7. Press any button on your Minimote to take it out of inclusion mode.

Exclusion from the Z-Wave Network (Z-Stick)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. Press the Action Button on your Micro Motor Controller.
  5. If your Micro Motor Controller has been successfully removed from your network, its Network LED will flash.
  6. If the removal was unsuccessful, the Network LED will not flash.
  7. Press the Action Button on the Z-Stick to take it out of removal mode.

Exclusion from the Z-Wave Network (Minimote)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Remove Button on your Minimote.
  4. Press the Action Button on your Micro Motor Controller.
  5. If your Micro Motor Controller has been successfully removed from your network, its Network LED will flash.
  6. If the removal was unsuccessful, the Network LED will not flash.
  7. Press any button on your Minimote to take it out of removal mode.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Dual Micro Switch G2
DCS17
Switch
Z-Wave

Factory Reset

  1. Press and hold the button on the Micro Double Smart Energy Switch G2 for 20 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. If the Micro Double Smart Energy Switch G2 is installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  3. If the Micro Double Smart Energy Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. If the Micro Double Smart Energy Switch G iis installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  4. If the Micro Double Smart Energy Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Micro Switch G2
DSC26 / DCS18
Switch
Z-Wave

Factory Reset

  1. Press and hold the button on the Micro Switch G2 for 20 seconds and then release it.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. If the Micro Switch G2 is installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  3. If the Micro Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. If the Micro Switch G2 is installed for use with a light, the switch can be toggled to initiate pairing into the Z-Wave network (switch 6 times (ON to OFF or OFF to ON).
  4. If the Micro Switch G2 is uninstalled, the internal button can be pushed to initiate pairing into the Z-Wave network, but only if Micro is not already connected to an external switch.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Minimote
DSA03202
Button Controller
Z-Wave

Factory Reset

  1. Pull down the panel on the  Minimote
  2. Press and hold the bottom 2 buttons down. The Red and Blue LED will alternate faster and faster.
  3. When both Red and Blue LED become solid, you may let go.

Include a device from the Z-Wave Network

  1. Tap the Inclusion (+) button, LED should be flashing blue
  2. Tap the button on the device you want to add
  3. After the LED stops flashing rapidly, tap any button to get out of inclusion mode

Exclusion a device from the Z-Wave Network

  1. Tap the Exclusion (-) button, LED should flash red
  2. Tap button on the device you want to remove
  3. After LED stops flashing rapidly, tap any button to get out of the exclusion mode

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Multisensor Gen5
ZW074
Motion Sensor
Z-Wave

Factory Reset

  1. Press and hold Multisensor Gen5 Action button (For 20 seconds)
  2. The LED of the Multisensor Gen5 will flash faster and faster. At 20 seconds, the LED should become solid for 1-2 seconds to confirm factory reset.
  3. Release the Multisensor Gen5 Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave Button on your MultiSensor.
  3. You can test if your MultiSensor has been successfully synced with your Z-Wave network by pressing its Z-Wave Button. If you press the button and your sensor’s LED illuminates for a few seconds, then syncing has been successful.
  4. If the LED flashes when the button is pressed, the syncing has been unsuccessful and you should repeat the above steps.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on your MultiSensor.
  4. If your MultiSensor has been successfully removed from your network, its LED will flash when you press the Z-wave Button.
  5. If the removal was unsuccessful, the LED will stay solid for a few seconds when you press the Z-wave Button.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Multisensor 6
ZW100
Motion Sensor
Z-Wave Plus

Factory Reset

  1. Press the Action Button on your MultiSensor. The LED on Multisensor will flash red then change into a colorful gradient.
  2. If your MultiSensor has been successfully removed from your network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will flash.
  3. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your MultiSensor. The LED on Multisensor will flash Green rapidly, followed by a solid Green LED for 1 second for a successful inclusion, or a solid red LED for 1 second for a failed inclusion.
  3. You can test if your MultiSensor has been successfully included into your Z-Wave network by pressing its Action Button. If you press the button and your sensor's green LED is solid for a few seconds, then inclusion has been successful.
  4. If the green LED flashes when the button is pressed, the inclusion has been unsuccessful and you should repeat the steps from step 1.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your MultiSensor. The LED on Multisensor will flash red then change into a colorful gradient.
  4. If your MultiSensor has been successfully removed from your network, the RGB LED will be active with a colorful gradient for 3 seconds. When you press the Action Button on MultiSensor, its green LED will flash.
  5. If the removal was unsuccessful, the green LED will stay solid for a few seconds when you press the Action Button.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
NanoMote One
ZWA004
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the NanoMote button for 20 seconds.
  2. The LED will change from: Orange > Green > Red > Pink > Red
  3. Release the button on the second Red LED status. It will remain Red for 2 seconds
  4. Tap button again while second Red LED is illuminated (you'll have 2 seconds to do so).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Double click the NanoMote button, the LED will flash rapidly with a white color.
  3. If your NanoMote has been successfully added to your Z-Wave  network, its white LED will be solid for about 10 seconds, then flash green to indicate it is awake.
  4. If the adding was unsuccessful and the red LED will be solid for 2 seconds and then off, repeat the above steps.
    • If your NanoMote does not go to sleep on its own, press and hold for 2 seconds (or until LED turns orange) then release its button to put your NanoMote to sleep.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Double click the NanoMote button, the LED will become a solid green color.
  4. If your NanoMote has been removed from your Z-Wave network, its LED will begin cycling through a rainbow of colors.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
NanoMote Quad
ZWA003
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the NanoMote button for 20 seconds.
  2. The LED will change from: Orange > Green > Red > Pink > Red
  3. Release the button on the second Red LED status. It will remain Red for 2 seconds
  4. Tap button again while second Red LED is illuminated (you'll have 2 seconds to do so).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Double click the NanoMote button (can be any button), the LED will flash rapidly with a white color.
  3. If your NanoMote has been successfully added to your Z-Wave  network, its white LED will be solid for about 10 seconds, then flash green to indicate it is awake.
  4. If the adding was unsuccessful and the red LED will be solid for 2 seconds and then off, repeat the above steps.
    • If your NanoMote does not go to sleep on its own, press and hold for 2 seconds (or until LED turns orange) then release its button to put your NanoMote to sleep.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Double click the NanoMote button, the LED will become a solid green color.
  4. If your NanoMote has been removed from your Z-Wave network, its LED will begin cycling through a rainbow of colors.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Nano Dimmer
ZW111
Dimmer
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on the Nano Dimmer, the Green LED (basic secure indication) will flash to indicate the Nano Dimmer is entering into pairing mode.
  3. If the Nano Dimmer has been successfully added to your Z-Wave network, its RGB LED will be solid.
  4. If the pairing was unsuccessful, the Red LED will be on for 2 seconds and then remain a colorful gradient, repeat the steps above.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Nano Switch (with energy reading)
ZW116
Switch
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once on the Nano Switch.
  3. If inclusion is successful, the Green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the Red LED will be on for 2 seconds and then return to a colorful gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Dual Nano Switch (with energy reading)
ZW132
Switch
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once on the Dual Nano Switch.
  3. If inclusion is successful, the Green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the Red LED will be on for 2 seconds and then return to a colorful gradient.

Exclusion from the Z-Wave Network;

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).
Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Nano Switch (without energy reading)
ZW139
Switch
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it.
  2. Your Nano Switch will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once on the Nano Switch.
  3. If inclusion is successful, the Green LED will be on for 2 seconds, and then return to a solid indication. If inclusion is unsuccessful, the Red LED will be on for 2 seconds and then return to a colorful gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on the Nano Switch once or toggle the external manual switch 3 times in fast succession.
  4. If the Nano Switch has been successfully removed from your Z-Wave network, its RGB LED will remain colorful gradient. If the removal was unsuccessful, the RGB LED will still be solid (following the state of the output load).

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Range Extender (Aeon Labs Z-Wave Network Repeater)
DSD37
Switch
Z-Wave

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the Range Extender to a default state.

Join the Z-Wave Network (Z-Stick)

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Z-Stick.
  3. If Range Extender has been successfully linked to your Z-Wave network, its Network LED will no longer flash.
  4. If the linking was unsuccessful and the Network LED continues to flash repeat the above steps.
  5. Press the Action Button on the Z-Stick to take it out of installation mode.

Join the Z-Wave Network (Minimote)

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Include button on your Minimote.
  3. If the Range Extender has been successfully linked to your Z-Wave network, its Network LED will no longer flash.
  4. If the linking was unsuccessful and the Network LED continues to flash repeat the above steps.
  5. Press any button on your Minimote to take it out of inclusion mode.

Exclusion from the Z-Wave Network (Z-Stick)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Z-Stick.
  4. If your Range Extender has been successfully removed from your network, its Network LED will flash.
  5. If the removal was unsuccessful, the Network LED will not flash.
  6. Press the Action Button on the Z-Stick to take it out of removal mode.

Exclusion from the Z-Wave Network (Minimote)

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Remove Button on your Minimote.
  4. If your Range Extender has been successfully removed from your network, its Network LED will flash.
  5. If the removal was unsuccessful, the Network LED will not flash.
  6. Press any button on your Minimote to take it out of removal mode.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Range Extender 6
ZW117
Repeater
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave Button for 20 seconds to completely factory reset your Range Extender 6.
  2. During the time that you are holding your Range Extender 6 action button down, the LED will flash through these colors: Yellow (at 2 seconds) > Purple (at 5 seconds) > Red for 8 seconds (initializing factory reset) > Green for 20 seconds (factory reset complete) > Rainbow LED (ready to be paired to a new gateway).
  3. You may let go when the LED turns green. Your Range Extender will now be reset to its original settings, and the green LED will be solid for 2 seconds and then remain the colorful gradient status as a confirmation.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave Button on your Range Extender and quickly release the button (should only be a quick tap action on the button) and its LED will flash green rapidly (green indicates insecure pairing, if you want to pair securely, please refer to Enabling Security Encryption section in the Advanced Function section).
  3. If Range Extender has been successfully added  to your Z-Wave network, its LED will be solid for 2 seconds then turn off. If the adding was unsuccessful, the red LED will be on for 2 seconds and then remain colorful gradient status, repeat the steps above.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave Button on your Range  Extender.
  4. If Range Extender has been successfully removed  from your network, its RGB LED will remain colorful gradient status.
  5. If the removal was unsuccessful, the RGB LED will still be solid, repeat the steps above.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Range Extender 7
ZW189
Repeater
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave Button for 20 seconds to completely factory reset your Range Extender 7.
  2. During the time that you are holding your Range Extender 7 action button down, the LED will cycle through these stages: OFF (at 1 second) > Pulsing (at 2 seconds) > Flash (at 5 seconds) > Fast Flashing (at 10 seconds) > Solid for 2 seconds then pulsing (at 20 seconds) indicating factory reset complete.
  3. You may let go of the button. Your Range Extender has now be reset to its original settings, and the LED will continuously pulse until added again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave Button on your Range Extender 7 and quickly release the button (should only be a quick tap of the action button).
  3. The Range Extender 7 will quickly flash its White LED up to 30 seconds, or until it is paired successfully.
  4. If successfully paired, the LED light will become brighter. If pairing fails, the LED will return to slow pulsing.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the button on your Range  Extender 7.
  3. If Range Extender has been successfully removed  from your network, its LED will be slowly pulsing.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Recessed Door Sensor Gen5
ZW089
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds and then release it. Your sensor will now be reset to its original settings

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Sensor. If your Sensor has been successfully linked to your network, its LED will become solid for 2 seconds then disappear.
  3. If linking was unsuccessful, the LED will continue to flash if you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Sensor. If your switch has been successfully unlinked to your network, its LED will begin to flash for a short time.
  4. If linking was unsuccessful, the LED will return to its last state. Tap the button to confirm if it has been unpaired, if unpaired successfully, the LED will flash when tapped.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Siren
ZW080
Siren
Z-Wave

Factory Reset

  1. Press and hold the Action button for 20 seconds
  2. At 8 seconds, the Siren will sound for 1 second, then stop
  3. The LED will continue to flash faster and faster and then will then turn solid for 2 seconds to indicate a successful factory reset
  4. You may let go of its Action button, and the Siren Gen5 factory reset is complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Siren Gen5, and its LED will flash rapidly to indicate that it is communicating.
  3. If your Siren has been successfully linked to your network, its LED will become solid for 2 seconds, then stop.
  4. If linking was unsuccessful, the LED will flash when you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Siren.
  4. If your Siren has been successfully unlinked from your network, its LED will begin to flash.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Siren 6
ZW164-A
Siren
Z-Wave Plus

Factory Reset

  1. Press and hold the Action button for 20 seconds
  2. Within 2-5 seconds, the test siren sound will run, then stop after 5 seconds has elapsed.
  3. From 5-10 seconds, the LED will begin to flash faster and faster still from 10-20 seconds.
  4. After 21 seconds, the LED will quickly flash 3 times, and then the LED slowly pulse up and down as you hold down the Action Button.
  5. With the LED pulsing, release the Action button, and the Siren 6 will be reset to factory defaults.

Join the Z-Wave Network

  1. Power Siren 6 through the provided power adapter.
  2. Ensure that Siren 6 LED is flashing slowly.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Quickly tap the Siren 6 Action Button once.
  5. If Siren 6 has successfully joined your Z-Wave network, the LED will emit a solid color for 30 seconds, then turn off.
  6. If the Siren 6 failed to pair, the LED will continue to flash slowly.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button 6 times within 2 seconds .
  4. If your Siren 6 has been successfully excluded from the Z-Wave network, its LED will begin to flash slowly which indicates that it is ready to be paired again.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Smart Energy Switch
DSC06106
Switch
Z-Wave

Factory Reset

  1. Use an Aeon Z-Stick or Minimote to return the sensor to a default state. If the Smart Energy Switch was removed from the Z-Wave network, the LED will be flashing. If it was not successfully removed from the Z-Wave network, the LED will either be solid ON or OFF (depending on if the switch is on or off).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the button on the device to include it in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Use an Aeon Z-Stick or Minimote to exclude the sensor from previous networks. If the Smart Energy Switch was removed from the Z-Wave network, the LED will be flashing. If it was not successfully removed from the Z-Wave network, the LED will either be solid ON or OFF (depending on if the switch is on or off).

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
Smart Switch 6
ZW096 / ZW110
Switch
Z-Wave Plus

Factory Reset

  1. Press and hold the Action Button for 20 seconds.
  2. The LED will change between these colors: Yellow > Purple > Red (flashs faster and faster) > Green (Successful indication of factory reset) > Rainbow LED (waiting to pair to new network).
  3. When the LED changes to Green state, you may let go of the action button.
  4. When the LED changes to a rainbow LED state, it will indicate that it is ready to pair to a new network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your Switch once and the LED will flash a green LED.
  3. If your switch has been successfully linked to your network, its LED will become solid green for 2 seconds.
  4. If linking was unsuccessful, the LED will return to a rainbow gradient.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your Switch.
  4. If your switch has been successfully unlinked from your network, its LED will become a rainbow gradient.
  5. If linking was unsuccessful, the LED will become green or purple depending on how your LED mode is set.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
TriSensor
ZWA005
Motion Sensor
Z-Wave

Factory Reset

  1. Press and hold the Action Button for 15 seconds.
  2. The red LED flashes to confirm a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button on your sensor once.
  3. The LED will turn yellow LED for 10 seconds.
  4. If the LED flashes green twice, then the sensor has successfully joined the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your sensor.
  4. The LED will turn purple for 2 seconds, and then white when exclusion is successful.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
WallMote Quad
ZW129
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the Action button for 20 seconds.
  2. The LED should flash between green, purple, then red which will flash rapidly until a green LED becomes solid for 2 seconds to indicate a successful factory reset.
  3. Let go of the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once on WallMote Quad to include it.
  3. The green LED will be on for 2 seconds and then the orange LED will fast flash for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your WallMote Quad.
  4. If your WallMote Quad is successfully removed from the Z-Wave network, the LED will become a colorful gradient for a few seconds and then turn off.
  5. If the removal was unsuccessful, the red LED will be solid for 2 seconds and then turn off, repeat the above steps.

Brand
Device
Product Number
Device Type
Protocol
Aeotec*
WallMote Quad
ZW130
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the Action button for 20 seconds.
  2. The LED should flash between green, purple, then red which will flash rapidly until a green LED becomes solid for 2 seconds to indicate a successful factory reset.
  3. Let go of the Action Button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Action Button once on WallMote Quad to include it.
  3. The green LED will be on for 2 seconds and then the orange LED will fast flash for 10 minutes (if the WallMote Quad does not receive the Wake Up No More Info command from primary Controller) to indicate the inclusion is successful.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Action Button on your WallMote Quad.
  4. If your WallMote Quad is successfully removed from the Z-Wave network, the LED will become a colorful gradient for a few seconds and then turn off.
  5. If the removal was unsuccessful, the red LED will be solid for 2 seconds and then turn off, repeat the above steps.

Alfred

Brand
Device
Product Number
Device Type
Protocol
Alfred
Smart Lock
DB2 / DB2-B
Lock
Z-Wave

Factory Reset

  1. Open the door and keep the lock bolt in the unlock position.
  2. Open the battery box to access the reset button.
  3. Using a pointed object, press and hold the reset button.
  4. Keep the reset button held down while removing and replacing one of the batteries.
  5. Keep holding the reset button down until you hear the voice guidance.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Touch the lock screen with your hand to activate it.
  3. Press * twice, followed by your master PIN code and #
  4. Digits 1-8 on the keypad should lightup in response.
  5. Enter 8, followed by 1 to put the lock into inclusion mode.
    • NOTE: It is recommended that you delete all user codes from the lock if any are previously existing and use Hubitat Elevation™ Lock Code Manager to program the lock.

Exclusion from the Z-Wave Network

  1. You must have your lock first connected to the August App
  2. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Touch the lock screen with your hand to activate it.
  5. Press * twice, followed by your master PIN code and #
  6. Digits 1-8 on the keypad should lightup in response.
  7. Enter 8, followed by 2 to put the lock into exclusion mode.

August

Brand
Device
Product Number
Device Type
Protocol
August
Smart Lock Pro
ASL-03
Lock
Z-Wave

Factory Reset

  1. You must have your lock first connected to the August App
  2. Go into Lock Settings > Z-Wave Settings. If you are connected, you will see Remove Z-Wave Device. Select Remove Z-Wave Device and on the next page you will see two options:
    • My Hub is in Exclusion Mode - use this mode when you have working hub and can properly disconnect.
    • My Hub is No Longer Working - use this mode to RESET the Device.
  3. Select the My Hub is No Longer Working option and then select Reset Z-Wave Device.

Join the Z-Wave Network

  1. You must have your lock first connected to the August App
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. On the August App, go into Lock Settings and door for Z-Wave Settings.
  4. The first time the screen will state that "The Lock is not connected to a Z-Wave Network". Select "Add to a Z-Wave Network".
  5. Follow the instructions to put the lock into Learn Mode.

Exclusion from the Z-Wave Network

  1. You must have your lock first connected to the August App
  2. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Go into Lock Settings > Z-Wave Settings. If you are connected, you will see Remove Z-Wave Device.
  5. Select Remove Z-Wave Device and on the next page you will see two options.
    • My Hub is in Exclusion Mode - Use this mode when you have a working hub and can properly disconnect.
    • My Hub is No Longer Working - Use this mode to RESET the Device.
  6. Select the My Hub is in Exclusion Mode option to exclude the lock from the Z-Wave network.

Aurora

Brand
Device
Product Number
Device Type
Protocol
Aurora
AOne Smart Remote
AU-A1ZBRC
Button Controller
Zigbee

Factory Reset

  1. Remove the battery cover.
  2. Press and hold the pairing button for 3 seconds before releasing.

Join the Zigbee Network

  1. Remove the battery cover.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press and hold the pairing button for 3 seconds before releasing. The light on the front of the remote will flash periodically to confirm it is searching for the hub.
  4. The light on the remote will remain solid for 10 seconds to confirm pairing was successful.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the battery cover.
  3. Press and hold the pairing button for 3 seconds before releasing.

Brand
Device
Product Number
Device Type
Protocol
Aurora
AOne Smart Plug-In Socket
AU-A1ZBPIAB
Socket
Zigbee

Factory Reset

  1. Plug in the socket.
  2. Press and hold the pairing button for 6 seconds before releasing.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the pairing button for 6 seconds before releasing. The light on the device will begin flashing.
  3. The light on the smart socket will stop flashing when pairing is sucessful.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the pairing button for 6 seconds before releasing.

Brand
Device
Product Number
Device Type
Protocol
Aurora
AOne Smart Double Socket
AU-A1ZBDSS
Socket
Zigbee

Factory Reset

  1. Press and hold the pairing button for 6 seconds before releasing.
  2. Cycle mains power to the outlet.

Join the Zigbee Network

  1. On initial power up, the device will automatically enter pairing mode for 3 minutes.
  2. Pairing is indicated by the LED light around the button flashing Blue quickly.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the pairing button for 6 seconds before releasing.
  3. Cycle mains power to the outlet.

BeSense

Brand
Device
Product Number
Device Type
Protocol
BeSense
Zwave PLUS Ceiling PIR Sensor
IX32
Motion Sensor
Z-Wave

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

Brand
Device
Product Number
Device Type
Protocol
BeSense
Zwave Plus Window/Door Sensor
IM20
Contact Sensor
Z-Wave

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

Brand
Device
Product Number
Device Type
Protocol
BeSense
Zwave PIR Sensor
IX30
Motion Sensor
Z-Wave

Factory Reset

  1. Press the tamper switch for 6 times to restore factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Activate the inclusion mode at the sensor by pressing the tamper switch 3 times.
  3. Wait about 15-30 seconds while the sensor and hub finish the inclusion process.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface, go to the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the tamper switch 3 times and the sensor will be removed from the Z-Wave network after 15-30 seconds.

BOSCH

Brand
Device
Product Number
Device Type
Protocol
BOSCH
PIR Motion Detector
ISW-ZPR1-WP13
Motion Detector
Zigbee

Factory Reset

  1. Unlock the battery cover and slide it upwards to remove.
  2. Press upward on the tamper switch located in-between the batteries, keeping it engaged while you remove both batteries.
  3. Wait at least 4 seconds, but do not release the tamper switch.
  4. Keep the tamper switch engaged while you reinsert both batteries.
  5. Release the tamper switch. The device is now reset to factory default settings.

Join the Zigbee Network

  1. Unlock the battery cover and slide it upwards to remove.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  3. Remove both batteries for at least 10 seconds.
  4. Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
  5. The LED will begin to flash On > Off > On > Off > On > Off (for 5 seconds) and will continue to flash in this cycle for up to 3 minutes
  6. If the motion sensor does not pair with the hub in less than 3 minutes, perform a factory reset and repeat the above steps to join the Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
Brand
Device
Product Number
Device Type
Protocol
BOSCH
PIR Motion Detector
ISW-ZDL1-WP11G
Motion Detector
Zigbee

Factory Reset

  1. Unlock the battery cover and slide it upwards to remove.
  2. Press upward on the tamper switch located in-between the batteries, keeping it engaged while you remove both batteries.
  3. Wait at least 4 seconds, but do not release the tamper switch.
  4. Keep the tamper switch engaged while you reinsert both batteries.
  5. Release the tamper switch. The device is now reset to factory default settings.

Join the Zigbee Network

  1. Unlock the battery cover and slide it upwards to remove.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Pairing on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  3. Remove both batteries for at least 10 seconds.
  4. Reinsert both batteries. The LED on the front of the sensor will be solid for 2 seconds
  5. The LED will begin to flash On > Off > On > Off > On > Off (for 5 seconds) and will continue to flash in this cycle for up to 3 minutes
  6. If the motion sensor does not pair with the hub in less than 3 minutes, perform a factory reset and repeat the above steps to join the Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Centralite

Brand
Device
Product Number
Device Type
Protocol
Centralite
Pearl Thermostat
3000-G
Thermostat
Zigbee

Factory Reset

  1. Enter Programming Mode, navigate to Menu ID “17”, press HOLD, then navigate to option “11”, then press HOLD again.
  2. The device will then factory reset itself and begin looking for an open network to join.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Enter Programming Mode, navigate to Menu ID “17”, press HOLD, then navigate to option “11”, then press HOLD again.
  3. The device will then factory reset itself and begin looking for an open network to join.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
Centralite
3-Series Smart Outlet
3200-G
Outlet
Zigbee

Factory Reset

  1. Unplug any devices from the module and unplug from the wall.
  2. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Unplug any devices from the module and unplug from the wall.
  3. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
Centralite
3-Series Door & Window Sensor
3300-G
Contact Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove cover, and remove battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
Centralite
3-Series Motion Sensor
3305-G
Motion Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove cover, and remove battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
Centralite
3-Series Micro Door Sensor
3323-G
Contact Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove cover, and remove battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
Centralite
3-Series Micro Motion Sensor
3328-G
Motion Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove cover, and remove battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
Centralite
4-Series Smart Outlet
4200-C
Outlet
Zigbee

Factory Reset

  1. Unplug any devices from the module and unplug from the wall.
  2. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Unplug any devices from the module and unplug from the wall.
  3. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.
  4. After the Smart Outlet has successfully joined a ZigBee network, the status LED will turn solid green

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Unplug any devices from the module and unplug from the wall.
  3. Hold the on/off button while plugging it back into the wall and continue to hold the button until the status LED turns on.

CREE

Brand
Device
Device Type
Protocol
CREE
Connected LED Bulbs
Bulb
Zigbee

Factory Reset

  1. Turn ON the bulb > pause 1 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 1 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 1 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb
  2. The bulb will flash once, indicating it is reset and ready for pairing

Factory Reset (Alternate Method)

  • Method 1 - Use a Philips Hue Dimmer Switch
  1. Turn the bulb on (ensure there are no others in the same lamp, as they could be reset too, using this method).
  2. Hold the remote within 4 inches of the bulb.
  3. Press and hold the 1st (On / I in some countries) and the 4th (Off / O in some countries) buttons simultaneously for about 10 seconds, until the bulb starts flashing on and off.
  4. If the bulb stopped flashing (it will normally turn fully on again after reset) and the green LED on the remote (top left of the remote) flashed green - your bulb is reset.
    • This method can be used for nearly ALL ZigBee LL bulbs.
  • Method 2 - Use a Lutron LZL-4B Connected Bulb Remote (Discontinued Product)
  1. Hold the remote within 4 inches of the bulb.
  2. Press and hold the 2nd (up arrow) and 4th (light off) buttons simultaneously.
  3. The bulb should flash on and off
  4. The green LED on the remote should come on and may flash a few times.
  5. Continue to hold both buttons on the remote until the green LED goes off completely.
    • This method can be used for nearly ALL ZigBee LL bulbs.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb > pause 2 seconds > turn OFF the bulb > pause 2 seconds > Turn ON the bulb
  3. The bulb will flash once, indicating it is reset and ready for pairing

Join the Zigbee Network (Alternate Method)

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. See Factory Reset (Alternate Method) above to reset the bulb and put it into pairing mode.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Dome

Brand
Device
Product Number
Device Type
Protocol
Dome
Door / Window Sensor
DMWD1
Contact Sensor
Z-Wave

Factory Reset

  1. Open the Cover and make sure the Door/Window Sensor is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator flashes once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the Cover of the Door/Window Sensor.
  3. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the Cover of the Door/Window Sensor.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
Door / Window Sensor
DMDP1
Contact Sensor
Z-Wave

Factory Reset

  1. Remove the Sensor Cover and confirm that your Door/Window Sensor is powered up.
  2. Wait for 5 seconds.
  3. Move the Magnet and Sensor Base in and out of the closed position 6 times.
  4. The LED indicator will light up Red for 5 seconds when reset successfully. The Door/Window Sensor’s memory will be erased to factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the Sensor Cover and the LED indicator will start flashing yellow.
  3. Press the Button quickly 3 times in a row.
  4. The device will enter inclusion mode for two minutes and the LED indicator will alternate between green and red. After successful inclusion, the LED Indicator will flash green 3 times then flash red until the cover is replaced.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the SENSOR COVER and the LED indicator will start flashing red.
  4. Press the Button quickly 3 times in a row.
  5. The LED Indicator will flash green 3 times indicating successful exclusion from the Z-Wave network. It will continue flashing red (indicating tamper) until the cover is replaced.

Brand
Device
Product Number
Device Type
Protocol
Dome
Leak Sensor
DMWS1
Water Sensor
Z-Wave

Factory Reset

  1. Open the Back Plate and make sure the Leak Sensor is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator flashs once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the cover of the Leak Sensor by twisting it apart.
  3. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the cover of the Leak Sensor by twisting it apart.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
Leak Sensor
DMMS1
Water Sensor
Z-Wave

Factory Reset

  1. Remove the Cover and make sure the Motion Detector is powered.
  2. Hold the Connect Button for 10 seconds until the LED indicator flashes once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the cover of the Motion Detector by twisting it apart.
  3. Press the Connect Button quickly 3 times in a row.
  4. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the cover of the Motion Detector by twisting it apart and make sure the Motion Detector is powered.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
Mouser
DMMZ1
Mouse Trap
Z-Wave

Factory Reset

  1. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  2. Press and hold the CONNECT BUTTON for at least 10 seconds then release.
  3. A flashing LED indicator indicates a successful factory reset. The Mousers memory will be erased to factory settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  3. Press the CONNECT BUTTON quickly 3 times in a row.
  4. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the TOP COVER by sliding it back and lifting up. Confirm that your Mouser is powered up.
  4. Press the CONNECT BUTTON quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
On/Off Plug-In Switch
DMOF1
Switch
Z-Wave

Factory Reset

  1. Plug in the On/Off Plug-In Switch.
  2. Hold the Connect Button for 10 seconds until the LED Indicator flashes once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Plug in the On/Off Plug-In Switch within range of your Z-Wave Controller.
  4. Press the Connect Button quickly 3 times in a row. The LED indicator will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
Range Extender
DMEX1
Repeater
Z-Wave

Factory Reset

  1. Hold the Button for 10 seconds until the LED flashes 10 times, then release the button

Join the Z-Wave Network

  1. For proper inclusion, install the Range Extender in the final location where it will be used.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Plug the Range Extender into an outlet or use a micro USB (not included) to power it. The LED will flash 5 times indicating successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Button quickly 3 times in a row The LED will flash 5 times indicating successful exclusion.

Brand
Device
Product Number
Device Type
Protocol
Dome
Siren
DMS01
Siren
Z-Wave

Factory Reset

  1. Open the Back Plate and make sure the Siren is powered.
  2. Hold the Connect Button for 10 seconds until the LED Ring flashs once, then release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the Back Plate of the Siren.
  3. Press the Connect Button quickly 3 times in a row. The LED Ring will flash 5 times indicating successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the Back Plate of the Siren.
  4. Press the Connect Button quickly 3 times in a row. The LED Ring will flash 5 times indicating successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Dome
Water Main Shut-Off
DMWV1
Shutoff Valve
Z-Wave

Factory Reset

  1. Press and hold the open/close button for at least 10 seconds then release.
  2. The Shut-Off’s memory will be erased to factory settings. A flashing light indicates a successful factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Make sure the Water Main Shut-Off is powered on, then press the “open/close” button quickly 3 times in a row. The LED will stop flashing and stay on continuously upon successful inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. When prompted, press the “open/close” button on the Shut-Off quickly 3 times in a row.

Dragon Tech

Brand
Device
Product Number
Device Type
Protocol
Dragon Tech
Plug in Z-Wave Plus Dimmer Switch
PD-100
Dimmer
Z-Wave

Factory Reset

  1. Unplug the PD-100 and anything the is plugged into it.
  2. Press and hold the button on the front of the PD-100
  3. Plug the PD-100 in while still pressing the button
  4. After 3 seconds, release the button. If the button flashes, the PD-100 has been successfully reset. If not, repeat the steps to factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the button on the front of the PD-100

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the button on the front of the PD-100

Eaton (Cooper Wiring Devices)

Brand
Device
Product Number
Device Type
Protocol
Eaton
Wireless Dimmer
RF9540
Dimmer
Z-Wave

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the device switch once to exclude it from the network. The LED will start flashing, indicating the dimmer has been successfully excluded from the Z-Wave network.

Join the Z-Wave Network

  1. Cooper Wiring Devices Z-Wave device has a blue LED, which will flash when the device is not included in a Z-Wave network. The LED stops flashing when the device is in a network.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the device switch once to include it in the network. The LED will stop flashing, indicating the dimmer has been successfully included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the device switch once to exclude it from the network. The LED will start flashing, indicating the dimmer has been successfully excluded from the Z-Wave network.

Ecolink

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Door / Window Sensor
DWZWAVE2.5-ECO
Contact Sensor
Z-Wave

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. When the exclusion process is complete, the LED on the sensor will be solid blue, then go out.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the battery for at least 5 seconds, then reinstall it.
  3. When the inclusion process is complete, the LED on the sensor will be solid blue, then go out.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. When the exclusion process is complete, the LED on the sensor will be solid blue, then go out.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Flood/Freeze Sensor
FLF-ZWAVE5
Water Sensor
Z-Wave Plus

Factory Reset

  1. The Flood Freeze sensor factory defaults on network exclusion
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for 1 second, then reinstall it.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the battery for at least 10 seconds, then reinstall it.
  3. If the LED starts flashing continuously, the sensor has no node ID and was not successfully added, so start from step 1 again. Make sure to remove the battery for 10 seconds if adding to a Z-Wave network fails.
  4. If after 5 seconds the LED is not flashing, look on Hubitat Elevation™ for feedback on whether the sensor was added successfully. If you do not see any feedback that the sensor was added, follow directions for exclusion of the sensor from a Z-Wave network, and then try adding the sensor again. If you are still having problems, you may need to add Z-Wave repeaters in-between the controller and the sensor.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Open the Flood Freeze case and remove the battery for 1 second.
  4. Replace the battery and the device should be removed from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Motion Sensor with Pet Immunity
PIR-ZWAVE2.5
Motion Sensor
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the battery for at least 5 seconds, then reinstall it.
  3. Re-attach the battery cover and the device with enter inclusion mode
  4. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the inclusion process.
  5. Test the sensor before mounting it permanently. Check Hubitat Elevation™ device details status to observe changes.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover and the device with enter exclusion mode
  5. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the exclusion process from step 2.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Siren
SC-ZWAVE5
Siren
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Plug in the Z-Wave Plus Siren and verify a single beep sound is heard.
  4. The LED on the front of the unit will turn off if successful exclusion from the network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Plug in the Z-Wave Plus Siren and verify a single beep sound is heard.
  3. The LED on the front of the unit will turn off if successful included in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Plug in the Z-Wave Plus Siren and verify a single beep sound is heard.
  4. The LED on the front of the unit will turn off if successful exclusion from the network.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
FireFighter
FF-ZWAVE5
Smoke/CO Detector
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Open the FireFighter case and press the learn button on the device for 1 second.
  4. If successfully removed from the Z-Wave Plus network, the devices Green LED should flash slowly continuously

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Open the FireFighter case and press the learn button on the device for 1 second.
  3. If the LED starts flashing continually, the sensor has not been added. Repeat the steps.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Open the FireFighter case and press the learn button on the device for 1 second.
  4. If successfully removed from the Z-Wave Plus network, the devices Green LED should flash slowly continuously

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Smart Switch
DLS-ZWAVE5
Switch
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the inclusion / exclusion button on the Smart Switch.
  3. The LED on the front of the unit will turn off if successfully included in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Smart Switch Double Toggle
DTLS2-ZWAVE5
Switch
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the inclusion / exclusion button on the Smart Switch.
  3. The LED on the front of the unit will turn off if successful included in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Smart Switch Dual Rocker
DDLS2-ZWAVE5
Switch
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the inclusion / exclusion button on the Smart Switch.
  3. The LED on the front of the unit will turn off if successful included in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Tilt Sensor
TILT-ZWAVE2
Tilt Sensor
Z-Wave

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the battery for at least 5 seconds, then reinstall it.
  3. Re-attach the battery cover and the device with enter inclusion mode
  4. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the inclusion process.
  5. Test the sensor before mounting it permanently. The sensor LED will flash each time the sensor position is changed. Check Hubitat Elevation™ device details status to observe changes.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover and the device with enter exclusion mode
  5. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the exclusion process from step 2.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Tilt Sensor
TILT-ZWAVE2.5
Tilt Sensor
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Remove the battery for at least 5 seconds, then reinstall it.
  3. Re-attach the battery cover and the device with enter inclusion mode
  4. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the inclusion process.
  5. Test the sensor before mounting it permanently. The sensor LED will flash each time the sensor position is changed. Check Hubitat Elevation™ device details status to observe changes.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove the battery for at least 5 seconds, then reinstall it.
  4. Re-attach the battery cover and the device with enter exclusion mode
  5. The LED will flash for 10 seconds and the go out. If the sensor LED continues to flash, repeat the exclusion process from step 2.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Toggle Light Switch
TLS-ZWAVE5
Switch
Z-Wave Plus

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the inclusion / exclusion button on the Smart Switch.
  3. The LED on the front of the unit will turn off if successful included in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion / exclusion button on the Smart Switch.

Brand
Device
Product Number
Device Type
Protocol
Ecolink
Pet Immune Motion Detector
PIRZB1-ECO
Dimmer
Zigbee

Factory Reset

  1. Press and hold the tamper switch while inserting one of the batteries
  2. Release the tamper switch withing 4 seconds
  3. The LED will flash 3 times every 5 seconds indicating the device is ready for paring

Join the Zigbee Network

  1. Press and hold the tamper switch while inserting one of the batteries
  2. Release the tamper switch withing 4 seconds
  3. The LED will flash 3 times every 5 seconds indicating the device is ready for paring
  4. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the tamper switch while inserting one of the batteries
  3. Release the tamper switch withing 4 seconds
  4. The LED will flash 3 times every 5 seconds indicating the device is ready for paring again.

Enerwave

Brand
Device
Product Number
Device Type
Protocol
Enerwave
Ceiling Mounted PIR Motion Sensor
ZWN-BPC-Plus
Motion Sensor
Z-Wave Plus

Factory Reset

  1. To reset the ZWN-BDC-PLUS, simply press the exclusion button on the sensor 3 times and hold for 3 seconds on the 3rd press.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the inclusion/exclusion button on the sensor 3 times.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the inclusion/exclusion button on the sensor 3 times.

Eva Logik

Brand
Device
Product Number
Device Type
Protocol
Eva Logik
Smart Plug
ZW36
Outlet
Z-Wave Plus

Factory Reset

  1. Hold the button for 5 seconds when powered on

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. Press the button on the switch 3 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Top button on the switch 3 times within 2 seconds.
Brand
Device
Product Number
Device Type
Protocol
Eva Logik
Smart Plug
ZW37
Outlet
Z-Wave Plus

Factory Reset

  1. Hold the button for 10 seconds when powered on

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. Press the button on the switch 3 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Top button on the switch 3 times within 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Eva Logik
Smart Plug
ZW39
Dimmer
Z-Wave Plus

Factory Reset

  1. Press and hold the top button for at least 3 seconds while you plug the smart switch into a receptacle

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
    • See Discovering your devices for detail instructions.
  2. Press the button on the switch 3 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the button on the switch 3 times within 2 seconds.

Everspring

Brand
Device
Product Number
Device Type
Protocol
Everspring
Door/Window Detector
HSM02
Contact Sensor
Z-Wave

Factory Reset

  1. Press the tamper switch three times within 1.5 second. The LED will be steady on.
  2. Within 1 second, press and hold the tamper switch until LED is off.
  3. The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Pressing the tamper switch three times within 1.5 second and the sensor will enter inclusion mode.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Pressing the tamper switch three times within 1.5 second will enter exclusion mode. The LED will light up once, each time the tamper switch is pressed.

Brand
Device
Product Number
Device Type
Protocol
Everspring
Flood Detector
ST812
Water Sensor
Z-Wave

Factory Reset

  1. Press the link key three times within 1.5 second. The sensor will beep each time the link key is pressed.
  2. Within 1 second, press and hold the link key. The sensor will long beep for 5 seconds. Keep holding the link key until the long beep stops.
  3. The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Pressing the link key three times within 1.5 second and the sensor will enter inclusion mode. The sensor will beep once, each time the link key is pressed.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Pressing the link key three times within 1.5 second will enter exclusion mode. The sensor will beep once, each time the link key is pressed.

Brand
Device
Product Number
Device Type
Protocol
Everspring
Temperature/Humidity Detector
ST814
Temperature Sensor
Z-Wave

Factory Reset

  1. Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.
  2. Within 1 second, press the temperature unit/linking key again, and the sensor will emit a long beep. Keep holding the temperature unit/linking key until the long beep stops.
  3. When the radio frequency status shows no signal, the device has been excluded from any previously joined Z-Wave networks and has been reset to factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Pressing the temperature unit/linking key 3 times within 1.5 seconds will enter inclusion mode. The linking signal symbol will flash on the display.
  4. When the radio frequency status shows no signal, the device has been excluded from any previously joined Z-Wave networks

Brand
Device
Product Number
Device Type
Protocol
Everspring
Illumination Sensor
ST815
Light Sensor
Z-Wave

Factory Reset

  1. Press the ESC button three times within 1.5 second.
  2. Within 1 second, press and hold the ESC button.
  3. The sensor will long beep. Keep holding the link key until the long beep stops.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the ESC button three times within 1.5 second and the sensor will enter inclusion mode. The sensor LED will flash.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the ESC button three times within 1.5 second and the sensor will enter exclusion mode. The sensor LED will flash.

Brand
Device
Product Number
Device Type
Protocol
Everspring
PIR Detector
HSP02
Motion Sensor
Z-Wave

Factory Reset

  1. Press tamper switch three times within 1.5 second. The LED will be steady on.
  2. Within 1 second, press and hold the tamper switch until LED is off.
  3. The LED will cycle on for 2 seconds and off for 2 seconds indicating the sensor has been reset for factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Pressing tamper switch three times within 1.5 second and the sensor will enter inclusion mode.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Pressing tamper switch three times within 1.5 second will enter exclusion mode.

Brand
Device
Product Number
Device Type
Protocol
Everspring
Photoelectric Smoke Alarm
SF813
Smoke Detector
Z-Wave

Factory Reset

  1. Press tamper switch three times within 1.5 second. The LED flashes and the buzzer sounds when the link key is pressed.
  2. Within 1 second, press and hold the tamper switch for 5 seconds until the LED is off.
  3. The LED will light for 5 seconds and the buzzer will sound for 5 seconds

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Pressing tamper switch three times within 1.5 second and the sensor will enter inclusion mode. The LED flashes and the buzzer sounds when the link key is pressed.
  3. The detector will stay awake and remain in inclusion mode for 10 minutes, or until the device has successfully joined the Z-Wave network.,
  4. The LED will light for 1 second and the buzzer will sound for 1 second to indicated the detector has joined the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Pressing tamper switch three times within 1.5 second and the sensor will enter exclusion mode. The LED flashes and the buzzer sounds when the link key is pressed.
  4. The detector will stay awake and remain in exclusion mode for 10 minutes, or until the device has successfully joined the Z-Wave network.,
  5. The LED will light for 1 second and the buzzer will sound for 1 second to indicated the detector has been excluded from the Z-Wave network.

Evolve

Brand
Device
Product Number
Device Type
Protocol
Evolve
Isolated Contact Fixture Module
LFM-20
Relay
Z-Wave

Factory Reset

  1. Factory reset is unavailable for this device. Instead, perform a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Exclude the module by tapping the button 3 times, then press and hold for 10 seconds.
    • LFM-20 release 5.41 requires that you tap 2 times, then press and hold for 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the button on the device once to include it in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Exclude the module by tapping the button 3 times, then press and hold for 10 seconds.
    • LFM-20 release 5.41 requires that you tap 2 times, then press and hold for 10 seconds.

Fibaro

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Button
FGBS-001
Contact Sensor
Z-Wave

Factory Reset

  1. Remove and re-connect the power supply while holding down the B button
  2. After 10 seconds, remove and re-connect the power supply again.
  3. The settings of the device will be reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press the B button 3 times (the button is located in the center of the device).
  3. Watch the status in the device details page to confirm proper operation.
    • NOTE: Everytime changes are made to the configuration of TP and TD lines (1-wire), (i.e. When DS18B20 temperature sensors are Included or Excluded), it is necessary to perform an exclusion and repeated inclusion of the sensor modules to the hub. The system will enter into the programming mode only once all the connected sensors have been detected (about 10 seconds).

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly press the B button 3 times (the button is located in the center of the device).
  4. Wait for the removing process to end.
  5. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Button
FGPB-101
Outlet
Z-Wave

Factory Reset

  1. Click the Button exactly five times.
  2. Press and hold the Button for at least 5 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Click the button at least 6 times.
  3. Wait for the device to be added into the system, successful inclusion will be confirmed by Hubitat Elevation™
  4. Click the button 4 times to wake it up
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click the Button at least 6 times.
  4. Wait for the removing process to end.
  5. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Door/Window Sensor 2
FGDW-002
Contact Sensor
Z-Wave

Factory Reset

  1. Open the cover and remove the battery.
  2. Install the battery while holding both TMP buttons.
  3. The LED indicator will be flashing slowly for 5 seconds, but keep holding the buttons.
  4. Release one button when the LED indicator starts flashing quickly.
  5. Click the released button once to confirm initiation of the reset procedure.
  6. Wait a few seconds for a long flash of the LED indicator. Do not remove the battery.
  7. The LED indicator will flash 5 times quickly to confirm reset of the device.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press one of the TMP buttons quickly, 3 times in a row, while keeping other button is pressed.
  3. Wait for the inclusion process to end.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press one of the TMP buttons quickly, 3 times in a row, while keeping other button is pressed.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Flood Sensor
FGFS-101 FG3
Water Sensor
Z-Wave

Factory Reset

  1. Make sure the sensor is powered.
  2. Press and hold the TMP button.
  3. Wait for the visual LED indicator to glow yellow (4th position of the MENU).
  4. Release the TMP button.
  5. Click the TMP button once to confirm selection.
  6. After few seconds the device will restart with factory settings, which is signaled with the red visual indicator color and an acoustic signal.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Removed the battery for 10 seconds, and re-install it
  3. Wait for the inclusion process to end.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the TMP button quickly, 3 times in a row.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Flood Sensor ZW5
FGFS-101 ZW5
Water Sensor
Z-Wave Plus

Factory Reset

  1. Make sure the sensor is powered.
  2. Press and hold the TMP button.
  3. Wait for the visual LED indicator to glow yellow (4th position of the MENU).
  4. Release the TMP button.
  5. Click the TMP button once to confirm selection.
  6. After few seconds the device will restart with factory settings, which is signaled with the red visual indicator color and an acoustic signal.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the TMP button quickly, 3 times in a row.
  3. Wait for the inclusion process to end.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the TMP button quickly, 3 times in a row.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
KeyFob
FGKF-601 ZW5
Button Controller
Z-Wave Plus

Factory Reset

  1. Click O and simultaneously.
  2. Click or X until LED is Yellow - reset the device.
  3. Click + to confirm selection, or is you do not wish to reset at this time, click to exit the menu.
  4. The LED will pulse Yellow twice to confirm the device has been reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. LED will pulse White during the adding process.
  3. Wait for the inclusion process to end.
  4. Successful adding will be confirmed by the Z-Wave controller’s message.
  5. Successful inclusion will be confirmed by Hubitat Elevation™ and the remote LED will be Green.
  6. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click O and simultaneously.
  4. Click or X until LED is Green.
  5. Click + to confirm selection.
  6. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Motion Sensor ZW5
FGMS-001 ZW5
Motion Sensor
Z-Wave Plus

Factory Reset

  1. Open the cover
  2. Press and hold the B-button.
  3. Wait for visual indicator to glow Yellow (2nd menu position).
  4. Release the B button and then briefly click the B-button to confirm selection
  5. After few seconds the device will be reset, which is signaled with the Red, fading visual indicator color.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the B button quickly, three times in a row.
  3. Wait for the inclusion process to end.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the B button quickly, three times in a row.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
RGBW Controller
FGRGBW-101
RGBW Controller
Z-Wave

Factory Reset

  1. Disconnect the supply voltage.
  2. Press and hold the B button located inside the RGBW Controllers casing.
  3. Connect the the supply voltage, while still holding the B button.
  4. Release the B button.
  5. The B channel will turn on (blue channel).
  6. Disconnect the power supply.

Join the Z-Wave Network

(Auto Inclusion)

  1. Make sure the RGBW Controller is not connected to a supply.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Connect voltage supply to auto-include the RGBW Controller.
  4. The RGBW Controller will be automatically recognized and included in the Z-Wave network.
  5. Successful inclusion will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

(Manual Inclusion)

  1. Make sure the RGBW Controller is not connected to a supply.
  2. To disable auto-inclusion press the B button briefly, after re-connecting the RGBW Controller to its supply voltage.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Triple click the B button or any switch connected to I1-I4 inputs.
  5. The RGBW Controller will be recognized and included in the Z-Wave network.
  6. Successful inclusion will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple click the B button or any switch connected to I1-I4 inputs.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Single Switch 2
FGS-213
Switch
Z-Wave Plus

Factory Reset

  1. Switch off the mains voltage (disable the breaker).
  2. Remove the Switch 2 from the wall switch box.
  3. Switch on the mains voltage.
  4. Press and hold the B button to enter the menu until the visual LED indicator is Yellow.
  5. Quickly release and click the B button again.
  6. After few seconds the device will be restarted, which is signaled by the Red LED indicator color.

Join the Z-Wave Network

  1. Identify the S1 switch.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Quickly, three times press the S1 switch.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly, three times press the S1 switch.
  4. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Radiator Thermostat
FIBEFGT-001
Thermostat
Z-Wave Plus

Factory Reset

  1. Press and hold the button at the base of the thermostat head.
  2. Release when the LED ring is Yellow.
  3. Briefly press the button to confirm selection.
  4. The device will reset and then go into Standby Mode.
  5. Briefly press the button to activate the thermostat again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly 3 times in a row, press the at the base of the thermostat head.
  3. The LED ring will start flashing White.
  4. Successful inclusion will be confirmed by Hubitat Elevation™ and the LED ring will show Green.
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Quickly 3 times in a row, press the at the base of the thermostat head.
  3. The LED ring will start flashing White.
  4. Successful exclusion will be confirmed by Hubitat Elevation™ and the LED ring will show Red.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Wall Plug
FGWPB-111 / FGWPB-121
Outlet
Z-Wave Plus

Factory Reset

  1. Make sure the device is powered.
  2. Press and hold the button.
  3. Wait for the LED frame to glow yellow (3rd menu position).
  4. Release the button and then briefly click the button once to confirm the selection.
  5. After few seconds the device will restart with factory settings, which is signaled with the red frame color.

Join the Z-Wave Network

  1. Plug the device into a socket.
  2. The LED frame will glow red signaling it has not being added (If is doesn't you must first perform a general exclusion and then a factory reset).
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Quickly, triple click the button located on the casing.
  5. Successful inclusion will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Plug the device into a socket.
  3. Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. The LED frame will glow green signaling it is currently included in a Z-Wave network (If it doesn't, then the exclusion process is not needed at this time).
  5. Quickly, triple click the button located on the casing.
  6. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Wall Plug
FGWPE-102
Outlet
Z-Wave

Factory Reset

  1. Press and hold the button located on the side.
  2. The device will cycle through GREEN, then VIOLET, and finally YELLOW for device reset.
  3. Release the button.
  4. Press the button again to confirm the selection and factory reset the device.

Join the Z-Wave Network

  1. Plug the device into a socket nearby the main Z-Wave controller.
  2. The LED frame will glow red signaling not being added (reset or remove the device otherwise).
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Quickly, triple click the button on the side of the device.
  5. The device will be included to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly, triple click the button on the side of the device.
  4. Plug the device into a socket nearby the main Z-Wave controller.
  5. The LED frame will glow green signaling being added (removing is not necessary otherwise).
  6. Quickly, triple click the button on the side of the device.
  7. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Fibaro
Dimmer 2
FGS-212
Switch
Z-Wave Plus

Factory Reset

  1. Switch off the mains voltage (disable the breaker).
  2. Remove the Dimmer 2 from the wall switch box.
  3. Switch on the mains voltage.
  4. Press and hold the B button to enter the menu until the visual LED indicator is Yellow.
  5. Quickly release and click the B button again.
  6. After few seconds the device will be restarted, which is signaled by the Red LED indicator color.
  7. The device enters the calibration mode.

Join the Z-Wave Network

  1. Identify switch no. 1 (turns the light on) or the B-button (located on the device’s housing).
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Quickly press switch no. 1 or the B button three times.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. Identify the S1 switch on the Fibaro Single Switch 2 From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly press switch no. 1 or the B button three times.
  4. The device will be excluded from the Z-Wave network.
  5. Dimmer 2 will start the calibration process

First Alert

Brand
Device
Product Number
Device Type
Protocol
First Alert
Smoke & Carbon Monoxide Combo Alarm
ZCOMBO-G
Smoke / CO Detector
Z-Wave

Factory Reset

  1. Power up the device with the test button held down for 10 or more seconds
  2. The device will reset all Z-Wave settings and leave the network. NOTE: The device will not remain awake after resetting and will go into standby mode.

Join the Z-Wave Network

  1. Slide battery door open and insert batteries.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will remain awake for 30 seconds on inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Slide battery door open, then remove and re-insert batteries.
  4. Press and hold the test button. Keep it held down as you slide the battery drawer closed. You may then release the button and the alarm will be excluded from the network.

FortrezZ

Brand
Device
Product Number
Device Type
Protocol
FortrezZ
Multiple In / Out module
MIMO2+
Relay
Z-Wave Plus

Factory Reset

  1. Press and hold the program button for 15 seconds and then release.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Briefly press the program button once.
  3. The status LED will flash when inclusion to the Z-Wave network completes.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Briefly press the program button once.
  4. The status LED will flash when the device has been excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
FortrezZ
Multiple In / Out module
MIMOLite
Relay
Z-Wave Plus

Factory Reset

  1. Press and hold the program button for 15 seconds and then release.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. When the LED has a periodic single flash, the unit will be automatically included to the Z-Wave network.
  3. If the LED is not flashing, then the button has been previously pressed and automatic inclusion mode is no longer active. In this case, briefly press the program button once.
  4. The status LED will flash when the device has been excluded from the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Briefly press the program button once.
  4. The status LED will flash when the device has been excluded from the Z-Wave network.

GE/Jasco

Brand
Device
Product Number
Device Type
Protocol
GE
Link Bulb
Bulb
Zigbee

Factory Reset

  1. Turn OFF the light for 3 second.
  2. Turn ON the light for 3 seconds
  3. Repeat this process 5 times
  4. The bulb will dim and then flash once when successfully reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn the bulb on.
  3. The bulb will flash when connected to the hub.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-in Dimmer
12718
Dimmer
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-in Switch
12719/ZW4101
Switch
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Outdoor Plug-in Switch
12720/ZW4201
Switch
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Outlet
12721
Outlet
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Switch
12722
Switch
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Dimmer
12724
Dimmer
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Toggle Switch
12727
Switch
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press up and release the toggle switch to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press up and release the toggle switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press up and release the toggle switch to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Toggle Dimmer
12729
Dimmer
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press up and release the toggle switch to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press up and release the toggle switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press up and release the toggle switch to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Fan Control
12730/ZW4002
Fan Controller
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless fan control rocker to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-In Outdoor Switch
14284
Switch
Z-Wave Plus

Factory Reset

  1. Unplug the switch from the outlet
  2. Press and hold the manual/program button on the switch for at least three seconds while you plug the switch into an outlet

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Fan Control
14287
Fan Controller
Z-Wave Plus

Factory Reset

  1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless fan control rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart fan control rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Tamper Resistant Outlet
14288
Outlet
Z-Wave Plus

Factory Reset

  1. Press the manual/program button 3 times, then press and hold the button for at least 3 seconds. The LED will flash 5 times to confirm.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Switch
14291
Switch
Z-Wave Plus

Factory Reset

  1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart switch rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart switch rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Dimmer
14294
Dimmer
Z-Wave Plus

Factory Reset

  1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Smart Motion Switch
26931
Switch
Z-Wave Plus

Factory Reset

  1. Press and release the top button 10 times within 5 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom button on the smart switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom button on the smart switch to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Smart Motion Switch
26933
Switch
Z-Wave Plus

Factory Reset

  1. Press and release the top button 10 times within 5 seconds. The LED will flash 3 times quickly confirming change

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom button on the smart switch to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top button on the smart switch to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-in Dimmer
28167
Dimmer
Z-Wave Plus

Factory Reset

  1. If plugged in, unplug the Dimmer from the receptacle.
  2. Press and hold the top button for at least 3 seconds while you plug the dimmer into a receptacle.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-in Dimmer
28169
Dimmer
Z-Wave Plus

Factory Reset

  1. If plugged in, unplug the Dimmer from the receptacle.
  2. Press and hold the top button for at least 3 seconds while you plug the dimmer into a receptacle.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the manual/program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the manual/program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Hinge Pin Smart Door Sensor
32563/ZW6301
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and release the program button 10 times quickly.
  2. The LED light will flash approximately eight times.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Single press and release the program button on the device to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Single press and release the program button on the device to exclude it from the network.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Plug-In Switch
45853
Switch
Zigbee

Factory Reset

  1. Unplug the switch.
  2. Hold the button and plug in the switch.
  3. Keep the button held down for 10 seconds.

Join the Zigbee Network

  1. Remove power from the dimmer at the circuit breaker.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Unplug the switch.
  4. Hold the button and plug in the switch.
  5. Keep the button held down for 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Unplug the switch.
  3. Hold the button and plug in the switch.
  4. Keep the button held down for 10 seconds.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Switch
45856
Switch
Zigbee

Factory Reset

  1. Tap the top of the rocker (ON Switch) with 10 quick short presses.

Join the Zigbee Network

  1. Remove power from the dimmer at the circuit breaker.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Restore power to the Smart Dimmer at the circuit breaker
  4. Pairing Begins Automatically: LED Status Indicator flashs as the Smart Dimmer automatically scans for a compatible network controller to pair with.
  5. After the Smart Dimmer is located and paired to the ZigBee network, the LED Status Indicator will stop flashing and the Smart Dimmer.
    • Note: LED Status Indicator stops flashing if a timeout occurs: Auto-Scan mode will eventually time out if the device has not joined a ZigBee network. Press and release the front panel to restart pairing process following timeout.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Dimmer
45857
Dimmer
Zigbee

Factory Reset

  1. Lift the air-gap switch at the bottom of the rocker to OFF position to power down the device.
  2. Hold down the UP button
  3. Push In the air-gap switch to ON position to power up the device.
  4. Release the UP button within 4 seconds of power up.

Join the Zigbee Network

  1. Remove power from the dimmer at the circuit breaker.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Restore power to the Smart Dimmer at the circuit breaker
  4. Pairing Begins Automatically: LED Status Indicator flashes as the Smart Dimmer automatically scans for a compatible network controller to pair with.
  5. After the Smart Dimmer is located and paired to the ZigBee network, the LED Status Indicator will stop flashing and the Smart Dimmer.
    • Note: LED Status Indicator stops flashing if a timeout occurs: Auto-Scan mode will eventually time out if the device has not joined a ZigBee network. Press and release the front panel to restart pairing process following timeout.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
In-Wall Switch
46201
Switch
Z-Wave Plus

Factory Reset

  1. Quickly press ON (Top) button 3 times then immediately press the OFF (Bottom) button 3 times.
  2. The LED will flash ON/OFF 5 times when completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart switch rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart switch rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

Brand
Device
Product Number
Device Type
Protocol
GE/Jasco
Enbrighten Smart Dimmer
46203
Dimmer
Z-Wave Plus

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to perform a general exclusion.
    • 12xxx series devices do not support factory reset from the device. A Z-Wave general exclusion is the only option.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the top or bottom of the wireless smart dimmer rocker to add it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the top or bottom of the wireless smart dimmer rocker to exclude it from the network.
    • Note: While some switches have a small tab to pull out, commonly referred to as an Air Gap, certain older GE switches do not disable power to the internal Z-Wave radio when the air gap is pulled. In such cases, where a mains powered device is refusing to join Hubitat Elevation™, try Z-Wave Exclude and then cut the power at the breaker box for 30 seconds before attempting the discovery procedure again.

GLEDOPTO

Brand
Device
Product Number
Device Type
Protocol
GLEDOPTO
Mini RGB+CCT Controller
GL-MC-001
Bulb
Zigbee

Factory Reset

  1. Power ON the device and within 2 seconds, remove power.
  2. Repeat the OFF and ON 4 times in a row.
  3. The device will reset to factory default on the 5th time the power is applied.
  4. Reset is confirmed by the lights flashing 4 times.

Join the Zigbee Network

  1. Remove power from the GLEDOPTO Mini RGB+CCT controller.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Power ON the device and within 2 seconds, remove power.
  4. Repeat the OFF and ON 4 times in a row.
  5. The device will reset to factory default on the 5th time the power is applied.
  6. Reset is confirmed by the lights flashing 4 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Power ON the device and within 2 seconds, remove power.
  3. Repeat the OFF and ON 4 times in a row.
  4. The device will reset to factory default on the 5th time the power is applied.
  5. Reset is confirmed by the lights flashing 4 times.

GoControl

Brand
Device
Product Number
Device Type
Protocol
GoControl
Garage Door Controllers
GD00Z
Garage Door Opener
Z-Wave

Includes Linear GD00Z-2, GoControl GD00Z-4, Linear GD00Z-5, ADT GD00Z-6, GoControl GD00Z-7 and NuTone ND00Z

Factory Reset

  1. Reset the controller by pressing the Link button 5 times.
  2. A quick beep followed by a longer beep will indicate proper reset for the GD00Z series or ND00Z.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and release the Link button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and release the Link button.

Brand
Device
Product Number
Device Type
Protocol
GoControl
Door / Window Sensor
WADWAZ-1
Contact Sensor
Z-Wave

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

Join the Z-Wave Network

  1. Unscrew the screw fastening the rear cover and slide the rear cover down
  2. Insert a CR123A battery into the battery compartment and LED will start to flash slowly, which means the sensor has not yet performed inclusion with the controller.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  4. Once Hubitat Elevation™ discovers the device, the LED will stop flashing. If the LED does not stop flashing and is not discovered by your hub, relocate the WADWAZ-1 to within 100 feet (line of sight) of a Z-Wave repeater or your hub and restart Z-Wave Inclusion.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the program switch of WADWAZ-1 for 1 second and release. The LED light will flash continuously when the sensor has been successfully excluded.

Graber

Brand
Device
Product Number
Device Type
Protocol
Graber
Motorized Shades
Shade
Z-Wave

Network Reset

  1. Press and hold the button on the headrail end cap for 7 seconds or until the shade jogs once.
  2. Release the button.
    • NOTE: The will not reset the shade limits

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Place the single channel remote in programming mode by pressing and holding the programming button until the LED light bar begins to flash Green.
  3. Release the button.
  4. Successful inclusion will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Place the single channel remote in programming mode by pressing and holding the programming button until the LED light bar begins to flash Green.
  4. Release the button
  5. The shade will be excluded from the Z-Wave network.

Halo Labs

Brand
Device
Product Number
Device Type
Protocol
Halo
Halo+
LS001A
Smoke/CO Detector
Zigbee

Factory Reset

  1. To reset, hold down center button for approximately 20 or more seconds.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Once Halo greets you, it will automatically begin searching for a ZigBee network. Halo will glow for a couple minutes before timing out.
    • To awaken the detector, double-tap the center button or hold the button for approximately 3 or more seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Hold down the center button for approximately 20 ot more seconds. Halo will reset all ZigBee settings and leave the network. .

Hampton Bay

Brand
Device
Product Number
Device Type
Protocol
Hampton Bay
Wink Enabled Ceiling Fan Controller
MR101Z
Fan Controller
Zigbee

Factory Reset

  1. Turn off your fan for 3 seconds, then turn it on for 3 seconds (Repeat 5 times)
  2. The light will flash three times when the factory reset is successful.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn on your fan.
  3. When successful, the fan will turn on at low speed and the light will flash three times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the fan controller

Hank

Brand
Device
Product Number
Device Type
Protocol
Hank
One-Key Scene Controller
HKZW-SCN01
Button Controller
Z-Wave Plus

Factory Reset

  1. Press and holding the center "Z-button" for 20 seconds.
  2. Release the button after 20 seconds and the LED will stay yellow for 3 seconds.
  3. Within the 3 second period where the LED is yellow, short-press the Z-button to reset the controller to factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Insert the battery.
  3. Triple click the center "Z-button".
  4. If inclusion is successful, the LED will flash blue for less than 5 seconds, and then it will remain solid for 15 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. If exclusion is successful, the LED will flash orange for less than 5 seconds, and then it will remain solid for 3 seconds.

Brand
Device
Product Number
Device Type
Protocol
Hank
Four-Key Scene Controller
HKZW-SCN04
Button Controller
Z-Wave Plus

Factory Reset

  1. Press and holding the center "Z-button" for 20 seconds.
  2. Release the button after 20 seconds and the LED will stay yellow for 3 seconds.
  3. Within the 3 second period where the LED is yellow, short-press the Z-button to reset the controller to factory defaults.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Insert the battery.
  3. Triple click the center "Z-button".
  4. If inclusion is successful, the LED will flash blue for less than 5 seconds, and then it will remain solid for 15 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. If exclusion is successful, the LED will flash orange for less than 5 seconds, and then it will remain solid for 3 seconds.

Brand
Device
Product Number
Device Type
Protocol
Hank
RGBW LED Bulb
HKZW-RGB01
Bulb
Z-Wave Plus

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle power to the bulb off and on 3 times quickly.
  4. Within 3 times toggling the bulb, the final ending state of the switch or plug must be on.
  5. If the exclusion is successful, the RGB BULB will quicly flash orange for less than 5 seconds, and then it will remain solid for 3 seconds.
  6. The bulb will remain warm white after the exclusion procedure is complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Make sure power to the bulb is disconnected and the RGB BULB is close to the hub.
  3. Insert the bulb into a socket and then turn it on.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle power to the bulb off and on 3 times quickly.
  4. Within 3 times toggling the bulb, the final ending state of the switch or plug must be on.
  5. If the exclusion is successful, the RGB BULB will quickly flash orange for less than 5 seconds, and then it will remain solid for 3 seconds.
  6. The bulb will remain warm white after the exclusion procedure is complete.

Heiman

Brand
Device
Product Number
Device Type
Protocol
Heiman
Zigbee Gas Detector
HS1CG
Gas Detector
Zigbee

Factory Reset

  1. Plug in the gas detector. It will beep once and the indicator light will flash Green once.
  2. Before the detector Zigbee radio can be reset, the gas detector must be in a ready state. The indicator light will alternate Red and Yellow while it is warming up.
  3. After approximately 3 minutes, the detector indicator light will stop flashing Red and Yellow. It will now have a steady Green indicator light, denoting it is ready and has ented its working state.
  4. Using the included tool or a straightended paperclip inserted in the small hole on the side, press the reset button for 2 seconds.
  5. The Green indicator light will flash quickly, and after 3 seconds it will turn off briefly and then return to steady Green indicating thedetector has returned to its ready state.

Join the Zigbee Network

  1. Plug in the gas detector. It will beep once and the indicator light will flash Green once.
  2. Before the detector Zigbee radio can be reset, the gas detector must be in a ready state. The indicator light will alternate Red and Yellow while it is warming up.
  3. After approximately 3 minutes, the detector indicator light will stop flashing Red and Yellow. It will now have a steady Green indicator light, denoting it is ready and has ented its working state.
  4. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  5. Using the included tool or a straightended paperclip inserted in the small hole on the side, press the reset button for 2 seconds.
  6. The Green indicator light will flash quickly, and after 3 seconds it will turn off briefly and then return to steady Green indicating thedetector has returned to its ready state.

Leaving the Zigbee Network

  1. Ensure the gas detector is plugged ing and ready.
  2. Before the detector Zigbee radio can be reset, the gas detector must be in a ready state. The indicator light will alternate Red and Yellow while it is warming up.
  3. After approximately 3 minutes, the detector indicator light will stop flashing Red and Yellow. It will now have a steady Green indicator light, denoting it is ready and has ented its working state.From the device's details page, select Remove Device, then Remove
  4. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  5. Using the included tool or a straightended paperclip inserted in the small hole on the side, press the reset button for 2 seconds.
  6. The Green indicator light will flash quickly, and after 3 seconds it will turn off briefly and then return to steady Green indicating thedetector has returned to its ready state.

HomePro

Brand
Device
Product Number
Device Type
Protocol
HomePro
Exterior Appliance Module
ZRP110
Outlet
Z-Wave

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Tap the button on the front of the module once.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the button on the front of the module once.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Tap the button on the front of the module once.

Homeseer

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Indicator Light Sensor
HS-FS100-L+
Light Sensor
Z-Wave Plus

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the Z-Wave button inside the sensor body for 10 seconds
  4. If successful, the LED will flash 5 times.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave network button on the front of the unit one time and wait for the inclusion process to finish. This may take some time.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave network button on the front of the unit one time and wait for the exclusion process to finish. This may take some time.

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Perimeter Water Sensor
HS-FS100-W+
Water Sensor
Z-Wave Plus

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the Z-Wave button inside the sensor body for 10 seconds
  4. If successful, the LED will flash 5 times.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave network button on the front of the unit one time and wait for the inclusion process to finish. This may take some time.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave network button on the front of the unit one time and wait for the exclusion process to finish. This may take some time.

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Wall Dimmer
HS-WD200+
Dimmer
Z-Wave Plus

Factory Reset

  1. Turn dimmer on by tapping the top of the paddle once.
  2. Quickly tap top of the paddle 3 times.
  3. If light turns off and then on again, the dimmer is reset. If not, repeat manual reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the paddle of the dimmer to begin the inclusion process. This will take a few moments to complete.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Tap the paddle of the dimmer to begin the exclusion process. This will take a few moments to complete.

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Wall Switch
HS-WS200+
Switch
Z-Wave Plus

Factory Reset

  1. Turn dimmer on by tapping the top of the paddle once.
  2. Quickly tap top of the paddle 3 times.
  3. If light turns off and then on again, the dimmer is reset. If not, repeat manual reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the paddle of the dimmer to begin the inclusion process. This will take a few moments to complete.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Tap the paddle of the dimmer to begin the exclusion process. This will take a few moments to complete.

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Door/Window Sensor
HS-DS100+
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave button inside the sensor body for 20 seconds, the LED will stay on until the button is released.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Triple-click the Z-Wave button inside the sensor body and wait for the process to finish.
  3. If successful, the sensor body LED will flash briefly and then stay on for 3 seconds.
  4. If unsuccessful, the LED with flash briefly and then turn off. Should this happen, repeat the inclusion process.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple-click the Z-Wave button inside the sensor body.
  4. If successful, the LED will turn off within 1 second.
  5. If unsuccessful, the LED with flash for 5 seconds. Should this happen, repeat the exclusion process.

Brand
Device
Product Number
Device Type
Protocol
Homeseer
Leak Sensor
HS-LS100+
Water Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave button for 20 seconds. Release the button once the LED stops flashing and glows solidly

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Click the Z-Wave button inside the sensor body once and wait for the process to finish.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple-click the Z-Wave button inside the sensor body. Wait for the inclusion process to finish.

Honeywell

Brand
Device
Product Number
Device Type
Protocol
Honeywell
T-6 Pro Z-Wave Thermostat
TH6320ZW2003
Thermostat
Z-Wave Plus

Factory Reset

  1. Press and hold the Menu button for 5 seconds to access the Advanced Menu.
  2. Touch the left < or right > arrow keys .to go through the options in the advanced menu.
  3. Choose Reset

Join the Z-Wave Network

  1. To include the thermostat from Z-Wave network, go to the thermostat Menu, then Z-Wave Setup. and touch Select.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. If the inclusion procedure is successful, INCLUDED, the node ID, and the Z-Wave connected status icon appear on the screen. If the procedure fails, then FAILED TO INCLUDE will appear on the screen.
    • NOTE: • Before adding the thermostat to a Z-Wave network, check that it does not already belong to one. If the thermostat is included in Z-Wave network, it offers to Exclude. If the thermostat is excluded from Z-Wave network, it offers to include. You can also check the status by viewing the Node ID located in the thermostat MENU/ DEVICE INFO. An excluded thermostat should show zero for the Node ID (000).
    • Whether you are including or excluding thermostat from your Z-Wave network, first you have to initiate it on your Z-Wave controller. Please refer to the user manual of your Z-Wave controller. • For other specific tasks, such as adding the thermostat to home automation scenes or groups, refer to the Z-Wave controller instructions.
    • The T6 Pro Z-Wave thermostat works in the optional Z-Wave battery mode or normal power mode based on its power source. The Z-Wave power mode can only be changed when thermostat is NOT included in Z-Wave network. You can check the power mode in the thermostat menu under MENU/DEVICE INFO. • If 24 VAC power source is not used or available, the thermostat must be powered by batteries. The thermostat will operate in LSS mode (power-save, sleep mode) to help conserve battery life after it has been included in a Z-Wave network. The Z-Wave radio supports beaming. It allows other devices in the network to wake up the Z-Wave thermostat, accept commands, and then go back to sleep.
    • If you need the thermostat to operate AOS mode (always listening mode) to act as signal repeater and to increase network reliability, you need to ask your professional installer to power the thermostat by 24 VAC.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. To exclude the thermostat from Z-Wave network, go to the thermostat Menu, then Z-Wave Setup. and touch Select.

IKEA

Brand
Device
Product Number
Device Type
Protocol
IKEA SYMFONISK
Sound Remote
20370482
Button Controller
Zigbee

Factory Reset

  1. Remove the battery cover from the bottom of the remote and hold the button for 10 seconds to factory reset.
  2. Wait for at least 10 seconds after reset is complete before attempting to pair the remote.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery cover from the bottom of the remote and hold the button for 10 seconds.
  3. Save the device and without deleting it from the hub, repeat steps 1 and 2 above.
  4. The hub will report that it found the previously paired device.
    • NOTE: If you do not pair a second time with the device already in the Hubitat Elevation™ database, the remote may not work proplerly.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the battery cover from the bottom of the remote and hold the button for 10 seconds to factory reset.

Brand
Device
Product Number
Device Type
Protocol
IKEA TRÅDFRI
Warm White Bulb
1000 lm Warm White
Bulb
Zigbee

Factory Reset

  1. Cycle power 6 times. The bulb will begin to dim and finally flash one time to indicate that it has been successfully reset.
  2. Wait for at least 10 seconds after reset is complete before attempting to pair the bulb.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Cycle power 6 times. The bulb will begin to dim and finally flash 1 time to indicate that it has successfully joined the Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Cycle power 6 times. The bulb will begin to dim and finally flash one time to indicate that it has been successfully reset.
  3. Wait for at least 10 seconds after reset is complete before attempting to pair the bulb again.
Brand
Device
Product Number
Device Type
Protocol
IKEA TRÅDFRI
Outlet
Outlet
Zigbee

Factory Reset

  1. Using a straightened paperclip, insert it into the small hole on the left side of the outlet next to the LED.
  2. Press and hold the paperclip in the hole for at least 5 seconds (you will feel the paperclip depressing a tiny button inside the outlet).
  3. The LED will pulse quickly and then pulse slowly when you release the internal button.
  4. Wait for at least 10 seconds after reset is complete before attempting to pair the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Using a straightened paperclip, insert it into the small hole on the left side of the outlet next to the LED.
  3. Press and hold the paperclip in the hole for 2-4 seconds (you will feel the paperclip depressing a tiny button inside the outlet).
  4. The LED will pulse slowly when pairing and will be steady when pairing has been successfully completed.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Using a straightened paperclip, insert it into the small hole on the left side of the outlet next to the LED.
  3. Press and hold the paperclip in the hole for at least 5 seconds (you will feel the paperclip depressing a tiny button inside the outlet).
  4. The LED will pulse quickly and then pulse slowly when you release the internal button.
  5. Wait for at least 10 seconds after reset is complete before attempting to pair the device again.

Brand
Device
Product Number
Device Type
Protocol
IKEA TRÅDFRI
Signal Repeater
Repeater
Zigbee

Factory Reset

  1. Using a straightened paperclip, insert it into the small hole at the end of the repeater next to the USB port.
  2. Press and hold the paperclip in the hole for at least 5 seconds (you will feel the paperclip depressing a tiny button inside the repeater).
  3. An LED will pulse quickly and then pulse slowly when you release the internal button.
  4. Wait for at least 10 seconds after reset is complete before attempting to pair the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Using a straightened paperclip, insert it into the small hole at the end of the repeater next to the USB port.
  3. Press and hold the paperclip in the hole for 2-4 seconds (you will feel the paperclip depressing a tiny button inside the repeater).
  4. The LED will pulse slowly when pairing and will be steady when pairing has been successfully completed.
  5. The signal repeater will pair as Device. No driver will be assigned and it is not necessary to have one since this device only repeats Zigbee radio signals.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Using a straightened paperclip, insert it into the small hole at the end of the repeater next to the USB port.
  3. Press and hold the paperclip in the hole for at least 5 seconds (you will feel the paperclip depressing a tiny button inside the repeater).
  4. The LED will pulse quickly and then pulse slowly when you release the internal button.
  5. Wait for at least 10 seconds after reset is complete before attempting to pair the device again.

Innr

Brand
Device
Product Number
Device Type
Protocol
Innr
Smart Spot Colour GU10

RS 230 C

Bulb
Zigbee

Factory Reset

  1. Cycle power 6 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Cycle power 6 times.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Cycle power 6 times.

Inovelli

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Multi-White and Multi-Color Bulbs
Bulb
Z-Wave Plus

Factory Reset

  1. Power the bulb ON and OFF 6 times within 2 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Power the bulb ON and OFF 6 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Power the bulb ON and OFF 6 times within 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
In-Wall Switch
Switch
Z-Wave Plus

Factory Reset

  1. Hold the UP button for 5 seconds when powered on

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Top button on the switch 6 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Top button on the switch 6 times within 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Outlet
Outlet
Z-Wave Plus

Factory Reset

  1. Press and hold the top button for at least 3 seconds while you plug the outlet into a recepticle

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Once the controller is ready to include your device, press in and release the button on the switch 3-5 times within 3 seconds to include it in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Once the controller is ready to exclude your device, press in and release the button on the switch 3-5 times within 3 seconds to include it in the network.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Switch Module
Switch
Z-Wave Plus

Factory Reset

  1. Factory reset is accomplished by performing a general exclusion on the device.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the center button 5 times within 1 second to exclude it in the Z-Wave network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the center button 5 times within 1 second to include it in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the center button 5 times within 1 second to exclude it in the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Smart Switch/Smart Scene Switch

NZW30

Switch
Z-Wave Plus

Factory Reset

  1. Hold the UP button for 5 seconds when powered on

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Top button on the switch 6 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Top button on the switch 6 times within 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Smart Dimmer/Smart Scene Dimmer

NZW31

Dimmer
Z-Wave Plus

Factory Reset

  1. Hold the UP button for 5 seconds when powered on

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Top button on the switch 6 times within 2 seconds.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Top button on the switch 6 times within 2 seconds.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
Smart Scene Switch S2

LZW30-SN

Switch
Z-Wave Plus

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Hold down the configure button for 20 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the configure button 3 times. The LED bar will flash Blue.
  3. If the switch was included successfully, the bard will turn Green. If the inclusion process was not successful, the LED bar will turn Red.
  4. You can scheck the Z-Wave range by holding the configure button for 5-10 seconds. A Red bar indicates the switch is not in range of the controller or a signal repeater. Green indicates a good signal.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the configure button 3 times.

Brand
Device
Product Number
Device Type
Protocol
Inovelli
On/Off Switch S2

LZW30

Switch
Z-Wave Plus

Factory Reset

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Hold down the configure button for 20 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the configure button 3 times. The LED bar will flash Blue.
  3. If the switch was included successfully, the bard will turn Green. If the inclusion process was not successful, the LED bar will turn Red.
  4. You can scheck the Z-Wave range by holding the configure button for 5-10 seconds. A Red bar indicates the switch is not in range of the controller or a signal repeater. Green indicates a good signal.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the configure button 3 times.

IRIS

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Button

BTN900

Button
Zigbee

Factory Reset

  1. Squeeze the two sides of the smart button together by the ridges and gently pull them apart to reveal the battery compartment.
  2. Remove the battery for at least 10 seconds. Reinsert the battery.
  3. Within 10 seconds of reinserting the battery press the reset button next to the battery 8 times in a row, once per second.
  4. Upon a successful reset, the smart button will flash green indicating the device is now ready to pair.
    • NOTE: The green light can be dim, if you're in a well lighted area this light could be difficult to see.
  5. If your button does not flash green check your battery, then retry from step 2.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. With the smart button, squeeze the two sides together by the ridges and gently pull them apart to reveal the battery compartment.
  4. Remove and re-insert the battery. When the smart button begins looking for your hub, the light around the button will flash green.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Squeeze the two sides of the smart button together by the ridges and gently pull them apart to reveal the battery compartment.
  3. Remove the battery for at least 10 seconds. Reinsert the battery.
  4. Within 10 seconds of reinserting the battery press the reset button next to the battery 8 times in a row, once per second.
  5. Upon a successful reset, the smart button will flash green indicating the device is now ready to pair.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  6. If your button does not flash green check your battery, then retry from step 2.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Care Pendant

PDT900

Button Controller
Zigbee

Factory Reset

  1. Insert the supplied access tool into the small opening at the top of the key fob. Gently pry open the case to reveal the battery compartment.
  2. Remove the battery for at least 10 seconds. Reinsert the battery.
  3. Within 10 seconds of reinserting the battery, press either button 8 times in a row, once per second. The lights on the pendant should begin to flash.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Insert the supplied access tool into the small opening at the top of the pendant. Gently pry open the case to reveal the battery compartment.
  4. Insert the battery in the correct orientation. The pendant will light up and start flashing as it begins searching for your hub
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Insert the supplied access tool into the small opening at the top of the key fob. Gently pry open the case to reveal the battery compartment.
  3. Remove the battery for at least 10 seconds. Reinsert the battery.
  4. Within 10 seconds of reinserting the battery, press either button 8 times in a row, once per second. The lights on the pendant should begin to flash.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Door/Window Sensor

DWS800

Contact Sensor
Zigbee

Factory Reset

  1. Squeeze the sides and pop open the sensor to reveal the battery, remove the battery and wait 10 seconds.
  2. Reinsert the battery and immediately press the white reset button 8 times.
  3. Your Iris Contact Sensor should now be flashing green indicating it's ready to pair
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. On the large piece, remove the back by squeezing the semi-circles on either side.
  4. The sensor's LED will flash while searching for the hub.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Squeeze the sides and pop open the sensor to reveal the battery, remove the battery and wait 10 seconds.
  3. Reinsert the battery and immediately press the white reset button 8 times.
  4. Your Iris Contact Sensor should now be flashing green indicating it's ready to pair
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Keyfob

KEY903

Presence Sensor
Zigbee

Factory Reset

  1. Insert the supplied access tool into the small opening at the top of the key fob. Gently pry open the case to reveal the battery compartment.
  2. Remove the battery for at least 10 seconds. Reinsert the battery.
  3. Within 10 seconds of reinserting the battery, press either button 8 times in a row, once per second. The lights on the key fob should begin to flash.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Insert the supplied access tool into the small opening at the top of the key fob. Gently pry open the case to reveal the battery compartment.
  4. Insert the battery in the correct orientation. The fob will light up and start flashing as it begins searching for your hub.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Insert the supplied access tool into the small opening at the top of the key fob. Gently pry open the case to reveal the battery compartment.
  3. Remove the battery for at least 10 seconds. Reinsert the battery.
  4. Within 10 seconds of reinserting the battery, press either button 8 times in a row, once per second. The lights on the key fob should begin to flash.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Motion Sensor

MOT800

Motion Sensor
Zigbee

Factory Reset

  1. Squeeze the raised edges on the sides of the motion sensor to take it apart to expose the battery.
  2. Remove the battery for at least 10 seconds. Reinsert the battery.
  3. As soon as the battery is reinserted, press the reset button 8 times in a row, once per second. The lights on the top right corner of the motion sensor should begin to flash. (You may have to make a shadow over the device to see the flashing light). Once the light is flashing you're ready to pair.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. On the large piece, remove the back by squeezing the raised edges on both sides.
  4. Insert the battery. The sensor's LED will flash while searching for the hub.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Squeeze the raised edges on the sides of the motion sensor to take it apart to expose the battery.
  3. Remove the battery for at least 10 seconds. Reinsert the battery.
  4. As soon as the battery is reinserted, press the reset button 8 times in a row, once per second. The lights on the top right corner of the motion sensor should begin to flash. (You may have to make a shadow over the device to see the flashing light). Once the light is flashing you're ready to pair.
    • NOTE: The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V1 Smart Plug

SPG800

Outlet
Zigbee

Factory Reset

  1. Remove the Smart Plug from the receptacle.
  2. Press and hold the button on the front for 15 seconds.
  3. Insert the Smart Plug back into the receptacle.
  4. Immediately press the button on the front of the Smart Plug 8 times, allowing 1 second between each press.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Insert the Smart Plug into any wall outlet.
  4. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the Smart Plug from the receptacle.
  3. Press and hold the button on the front for 15 seconds.
  4. Insert the Smart Plug back into the receptacle.
  5. Immediately press the button on the front of the Smart Plug 8 times, allowing 1 second between each press.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Button

3460-L

Button
Zigbee

Factory Reset

  1. Remove battery. Wait 10 seconds then re-insert battery.
  2. Within 10 seconds after re-inserting battery, press the button 8 times. The light will very dimly flash solid blue, than flash blue (even more faintly).
    • NOTES: The + side of the battery should be facing the bottom of the button when you insert the tray. At this point, a blue light should be flashing on the button's top. If you don't see this, take the battery back out and try again.
    • The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. At this point, a blue light should be flashing on the button's top. If you don't see this, take the battery back out and try again.
    • NOTES: The + side of the battery should be facing the bottom of the button when you insert the tray. At this point, a blue light should be flashing on the button's top. If you don't see this, take the battery back out and try again.
    • The LED can be dim, if you're in a well lighted area this light could be difficult to see.
  4. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove battery. Wait 10 seconds then re-insert battery.
  3. Within 10 seconds after re-inserting battery, press the button 8 times. The light will very dimly flash solid blue, than flash blue (even more faintly).
    • NOTES: The + side of the battery should be facing the bottom of the button when you insert the tray. At this point, a blue light should be flashing on the button's top. If you don't see this, take the battery back out and try again.
    • The LED can be dim, if you're in a well lighted area this light could be difficult to see.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Door/Window Sensor

3320-L

Contact Sensor
Zigbee

Factory Reset

  1. Slide the battery cover off, remove the battery and wait 10 seconds.
  2. Using a paper clip, press and hold the reset button completely down while reinserting the battery.
  3. Hold the reset button for an additional 2 seconds and release. The contact sensor should begin flashing blue.
    • NOTE: The reset button is a small black button above the battery.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Remove battery. Wait 10 seconds then re-insert battery.
  4. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  5. After pairing test your Iris Contact Sensor is working by opening and closing the door or window it's set up on (The LED should flash GREEN when opened/closed)
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Slide the battery cover off, remove the battery and wait 10 seconds.
  3. Using a paper clip, press and hold the reset button completely down while reinserting the battery.
  4. Hold the reset button for an additional 2 seconds and release. The contact sensor should begin flashing blue.
    • NOTE: The reset button is a small black button above the battery

Brand
Device
Product Number
Device Type
Protocol
IRIS
Garage Door Opener

GD-00Z-1

Garage Door Opener
Z-Wave Plus

Factory Reset

  1. Unplug your device and wait 10 seconds
  2. Restore power to the device
  3. Press the Link (Z-Wave) button on the left side of the device 5 times within 10 seconds to reset your device.

Join the Z-Wave Network

  1. Perform a factory reset before attempting to join the Z-Wave network.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Ensure your Iris Garage Door Controller is plugged in, and the tilt sensor battery is active/working.
  4. Press the Link (Z-Wave) button once located on the left of the Iris Garage Door Controller.
  5. When your device triple beeps, it has successfully joined the Z-Wave network.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Once the controller is ready to exclude your device, press the Link (Z-Wave) button once located on the left side of the device.
  4. The garage door controller should give a short beep immediately followed by a long beep.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Keypad

3405-L

Keypad
Zigbee

Factory Reset

  1. Remove the battery and wait 10 seconds.
  2. Press and hold the tamper switch while inserting one battery. Hold tamper switch for 2 seconds after the battery is installed. The tamper switch is the little flat plastic tab located on the back where the mounting bracket connects to the device, it is above the battery compartment.
    • Note: The factory reset process puts the security keypad back into pairing mode.
  3. Upon a proper reset the top right icon will be flashing green on your keypad.
  4. You may now insert the 2nd battery.

Join the Zigbee Network

  1. Perform a factory reset before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Remove battery. Wait 10 seconds then re-insert battery.
  4. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Press and hold the tamper switch while inserting one battery. Hold tamper switch for 2 seconds after the battery is installed. The tamper switch is the little flat plastic tab located on the back where the mounting bracket connects to the device, it is above the battery compartment.
    • Note: The factory reset process puts the security keypad back into pairing mode.
  3. Upon a proper reset the top right icon will be flashing green on your keypad.
  4. You may now insert the 2nd battery.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V3 Keypad

iL02_1

Keypad
Zigbee

Factory Reset

  1. Remove only 1 AA battery and wait 10 seconds.
  2. Re-insert the battery while holding down the reset button on the left side of the keypad and release when the status light flashes Red once.
  3. A flashing blue light indicates the device is reset and ready to pair again.

Join the Zigbee Network

  1. Remove only 1 AA battery and wait 10 seconds.
  2. Re-insert the battery while holding down the reset button on the left side of the keypad and release when the status light flashes Red once.
  3. A flashing blue light indicates the device is reset and ready to pair again.
  4. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove only 1 AA battery and wait 10 seconds.
  3. Re-insert the battery while holding down the reset button on the left side of the keypad and release when the status light flashes Red once.
  4. A flashing Blue light indicates the device is reset and ready to pair again.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Motion Sensor

3326-L

Motion Sensor
Zigbee

Factory Reset

  1. Remove the battery and wait 10 seconds
  2. Press and hold the reset button on the left side of the device as you reinsert the battery.
  3. Hold for an additional 2 seconds and release.
    • Note: The reset button is a small white button located on the side of the motion sensor.
  4. Upon a successful reset your device will now be flashing Blue, indicating it's ready to pair.
  5. A flashing blue light indicates the device is reset and ready to pair again.

Join the Zigbee Network

  1. Factory reset the device before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Remove the battery for 10 seconds and re-insert.
  4. Replace the battery cover. The sensor's Blue LED will flash while searching for the hub.
  5. Once paired the LED will stop flashing.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Press and hold the reset button on the left side of the device as you reinsert the battery.
  3. Hold for an additional 2 seconds and release.
    • Note: The reset button is a small white button located on the side of the motion sensor.
  4. Upon a successful reset your device will now be flashing Blue, indicating it's ready to pair.
  5. A flashing blue light indicates the device is reset and ready to pair again.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V3 Motion Sensor

iL07_1

Motion Sensor
Zigbee

Factory Reset

  1. Remove the battery and wait 10 seconds.
  2. Re-insert the battery while holding down the reset button on the left side and release when the status light turns Red.
  3. A flashing Blue light indicates the device is ready to pair.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery and wait 10 seconds.
  3. Re-insert the battery while holding down the reset button on the left side and release when the status light turns Red.
  4. A flashing Blue light indicates the device is ready to pair.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the battery and wait 10 seconds.
  3. Re-insert the battery while holding down the reset button on the left side and release when the status light turns Red.
  4. A flashing Blue light indicates the device is ready to pair.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Smart Plug

3210-L

Outlet
Zigbee

Factory Reset

  1. Remove the Smart Plug from the outlet and wait 10 seconds.
  2. Press and hold the small white button on the front of the plug.
  3. While holding the button, insert the Smart Plug back into the outlet.
  4. As soon as the LED on the front of the plug lights up, release the button.
  5. If the reset was successful the Blue LED on the front of the smart plug will be flashing. This means your smart plug is now ready to pair.

Join the Zigbee Network

  1. Factory reset the device before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Insert your smart plug into any wall outlet. Your smart plug should be flashing Blue, that means it's in pairing mode.
  4. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  5. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Press and hold the small white button on the front of the plug.
  3. While holding the button, insert the Smart Plug back into the outlet.
  4. As soon as the LED on the front of the plug lights up, release the button.
  5. If the reset was successful the Blue LED on the front of the smart plug will be flashing. This means your smart plug is now ready to pair.

Brand
Device
Product Number
Device Type
Protocol
IRIS
V2 Smart Fob

3450-L

Button Controller
Zigbee

Factory Reset

  1. Twist open the battery cover on the back of the Smart Fob.
  2. Remove the battery and wait 10 seconds
  3. Reinstall the battery with the positive side facing you.
  4. Once the battery is installed, push any of the four buttons 8 times in a row, once per second.
  5. Confirm that the fob has been reset by checking that the fob's background light is flashing Blue. If it does not do this, check the battery and retry from step 2.

Join the Zigbee Network

  1. Factory reset the device before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Insert the battery so the plus sign is facing you. Put the cover on and twist tighten with a coin.
  4. The Smart Fob's LED will flash Blue while searching for the hub.
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Twist open the battery cover on the back of the Smart Fob.
  3. Remove the battery and wait 10 seconds
  4. Reinstall the battery with the positive side facing you.
  5. Once the battery is installed, push any of the four buttons 8 times in a row, once per second.

Brand
Device
Product Number
Device Type
Protocol
IRIS
Smart Water Sensor

3315-L

Water Sensor
Zigbee

Factory Reset

  1. Remove the cover from the sensor, then remove the battery for at least 10 seconds.
  2. Press and hold the reset button while reinserting the battery.
  3. Hold for an additional 2 seconds and release.
  4. A successful reset will be indicated by a flashing Blue light on your sensor

Join the Zigbee Network

  1. Factory reset the device before attempting to pair.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Remove the battery and wait 10 seconds.
  4. Re-insert the battery
  5. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  6. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the cover from the sensor, then remove the battery for at least 10 seconds.
  3. Press and hold the reset button while reinserting the battery.
  4. Hold for an additional 2 seconds and release.
  5. A successful reset will be indicated by a flashing Blue light on your sensor

KEEN Home

Brand
Device
Product Number
Device Type
Protocol
KEEN Home
Smart Vent
Vent
Zigbee

Factory Reset

  1. Press the black button on the back inside of the Smart Vent battery compartment 5 times.
  2. You will know that the Smart Vent has been properly reset when the LED starts double flashing Green

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Removed the battery cartridge and reinsert it to bring the vent online.
  3. Press the black button on the back inside of the Smart Vent battery compartment 5 times.
  4. This should force the vent into join-mode once again.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Press the black button on the back inside of the Smart Vent battery compartment 5 times.
  3. You will know that the Smart Vent has been properly reset when the LED starts double flashing Green

Kwikset

Brand
Device
Product Number
Device Type
Protocol
Kwikset
SmartCode
910 / 912 / 914
Lock
Z-Wave

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes Red.
  3. Press the Program button once more. When the LED flashes Green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Z-Wave Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your Z-Wave controller
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press button A on the lock one time to include it. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.
  4. If Inclusion is unsuccessful, go to the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  5. Press button A on the lock one time. Once the lock is fully Excluded from the system, repeat the Inclusion process.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press button A on the lock one time. Once the lock is fully Excluded from the system. The controller and lock must remain stationary for a total of 60 seconds during the Inclusion process.

Brand
Device
Product Number
Device Type
Protocol
Kwikset
SmartCode
910 / 912 / 914
Lock
Zigbee

Factory Reset

  1. Remove battery pack
  2. Press and HOLD the Program button while reinserting the battery pack. Keep holding the button for 30 seconds until the lock beeps and the status LED flashes Red.
  3. Press the Program button once more. When the LED flashes Green and you hear one beep, the lock has been reset.
  4. Perform the door handing process again.
    • Press and hold the Lock button while installing battery pack.
    • Hold button until the latch bolt starts moving on its own. If the latch bolt retract and extend on its own when the battery pack was installed, then the handing process was successful.
    • If the latch bolt does not retract and extend on its own, remove the battery pack and wait 15 seconds, before attempting the handing process again.

Join the Zigbee Network

  1. Hold the interior assembly a maximum of 12" (305 mm) from your hub.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press button A on the lock 4 times to pair it. The controller and lock must remain stationary for a total of 60 seconds during the pairing process.
    • If pairing is unsuccessful, press button B on the lock 9 times and repeat the pairing process.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press button B on the lock 9 times.

Leak Intelligence

Brand
Device
Product Number
Device Type
Protocol
Leak Intelligence
Leak Gopher
Valve
Z-Wave

Factory Reset

  1. Unplug your device and wait 10 seconds
  2. Restore power to the device
  3. Press the Link (Z-Wave) button on the left side of the device 5 times within 10 seconds to reset your device.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button once.
  3. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  4. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Once the controller is ready to exclude your device, press the Z-Wave button once.

Leviton

Brand
Device
Product Number
Device Type
Protocol
Leviton
Plug-in Outlet
DZPA1
Outlet
Z-Wave Plus

Factory Reset

  1. Hold the control button for a total of 7 seconds and the locator LED flashes Amber.
  2. Following the first 7 seconds, the locator LED will flash quickly, alternating between red and amber after 14 seconds.
  3. Release the top paddle to complete the reset process.

Join the Z-Wave Network

  1. Enter programming mode by holding the control button for 7 seconds until the locator LED flashes Amber.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Tap the control button one time and the locator LED will quickly flash green.
  4. Upon successful inclusion to the Z-Wave network, the LED will turn off and then flash Green 3 times.
  5. If inclusion fails, the LED will flash Red 3 times.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Enter programming mode by holding the control button for 7 seconds until the locator LED flashes Amber.
  4. Tap the locator button one time and the locator LED will quickly flash green.
  5. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Leviton
Smart Dimmer
DZ6HD
Dimmer
Z-Wave Plus

Factory Reset

  1. Hold the top paddle button for a total of 14 seconds.
  2. Following the first 7 seconds, the LED will turn amber.
  3. The locator LED will flash quickly, alternating between red and amber after 14 seconds.
  4. Release the top paddle to complete the reset process.

Join the Z-Wave Network

  1. Enter programming mode by holding the control button for 7 seconds until the locator LED flashs Amber.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Tap the locator button one time and the locator LED will quickly flash green.
  4. Upon sucessful inclusion to the Z-Wave network, the LED will turn off and then flash Green 3 times.
  5. If inclusion fails, the LED will flash Red 3 times.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Enter programming mode by holding the control button for 7 seconds until the locator LED flashs Amber.
  4. Tap the locator button one time and the locator LED will quickly flash green.
  5. The device will be excluded from the Z-Wave network.
Brand
Device
Product Number
Device Type
Protocol
Leviton
Switch
DL15S
Switch
Zigbee

Factory Reset

  1. Hold the top paddle for 14 seconds (after the first 7 seconds the LED will turn Amber).
  2. The Locator LED will alternate flashing Red and Amber after 14 seconds.
  3. Release the top paddle to complete the factory reset.

Join the Zigbee Network

  1. Hold the top paddle for 7 seconds (The locator LED will flash Amber).
  2. Tap the top paddle and the Locator LED will quickly flash Green
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the top paddle for 14 seconds (after the first 7 seconds the LED will turn Amber).
  3. The Locator LED will alternate flashing Red and Amber after 14 seconds.
  4. Release the top paddle to complete the factory reset.

Brand
Device
Product Number
Device Type
Protocol
Leviton
4-Scene Controller
VRCS4
Button Controller
Z-Wave

Factory Reset

  1. On the 4-Scene controller, press and hold buttons 1 and 3.
  2. Wait approximately 5 seconds until the LED turns amber and then solid red.
  3. Release the buttons and the 4-Scene controller will be reset. NOTE: Factory reset does not exclude the device from any previous networks it has joined. The exclusion process must still be performed separately.

Join the Z-Wave Network

Leaving the Z-Wave Network


Linear

Brand
Device
Product Number
Device Type
Protocol
Linear (GoControl)
Door / Window Sensor
WADWAZ-1
Contact Sensor
Z-Wave

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Depress the Tamper switch for 1 second then release. The LED on the sensor will begin flashing.
  3. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  4. The LED on the sensor will stop flashing
  5. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Tamper switch of WADWAZ-1 for 1 second and release to exclude the device form the Z-wave network.
  4. The LED light will flash continuously when the sensor is in the excluded condition.

Brand
Device
Product Number
Device Type
Protocol
Linear (GoControl)
PIR Motion Detector
WAPIRZ-1
Motion Sensor
Z-Wave

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Depress the Tamper switch for 1 second then release. The LED on the sensor will begin flashing.
  3. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  4. The LED on the sensor will stop flashing
  5. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Tamper switch of WAPIRZ-1 for 1 second and release to exclude the device form the Z-wave network.
  4. The LED light will flash continuously when the sensor is in the excluded condition.

Brand
Device
Product Number
Device Type
Protocol
Linear (GoControl)
Siren / Strobe
WA105DBZ-1
Siren
Z-Wave

Factory Reset

  1. Factory reset is achieved by performing a general exclusion.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the siren/strobe Program/Tamper switch for 1 second then release. The LED on the sensor will begin flashing.
  3. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  4. The LED on the sensor will stop flashing
  5. Watch the status in the device details page to confirm proper operation.

Exclusion the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the siren/strobe Program/Tamper switch for 1 second then release to exclude the device form the Z-wave network.
  4. The LED light will flash continuously when the sensor is in the excluded condition.

Lutron

Brand
Device
Product Number
Device Type
Protocol
Lutron
Dimmer

Aurora

Button Controller
Zigbee

Factory Reset

  1. Quickly press the center button 3 times and hold on the thrid press for aproximatley 6 seconds until the LED flashes.
  2. Once LED is flashing quickly tap button 3 time again.
  3. The LED will flash rapidly to indicate the device has been successfuly reset for factory defaults.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Quickly press the center button on the Aurora 2 times to begin pairing.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
Brand
Device
Product Number
Device Type
Protocol
Lutron
Lutron Dimmers and Switches
Dimmer / Switch
Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
Caséta Smart Bridge Pro
L-BDGPRO2
Bridge
Lutron Clear Connect

Network Reset

  1. First, press and hold the black button on the back of your Smart Bridge for 20 seconds.

Factory Reset

  1. Quickly tap the button 3 times and hold. DO NOT release after the third tap.
  2. Continue to hold the Add button for a few seconds. The LEDs will begin to flash slowly (approximately once per second).
  3. Release the button and quickly tap the button 3 times. The LEDs will flash quickly and then will turn off. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly)
  4. The Lutron Smart Bridge Pro has now been returned to Factory Default Settings.

NOTE: Lutron does not recommend factory resetting a Smart Bridge Pro unless advised by a member of the Lutron technical support team.


Brand
Device
Product Number
Device Type
Protocol
Lutron
Pico Remote
PJ2-
Button Controller
Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
Radio RA2 Keypads
Keypad
Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. The RA2 keypad has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
Radio RA2 Main Repeater
RR-MAIN-REP
Repeater
Lutron Clear Connect

Factory Reset

  1. Tap the Test button on a Main Repeater 3 times. DO NOT release the button after the third tap.
  2. Keep the Test button pressed on the third tap until all the LEDs start to flash red slowly (approximately 3 seconds).
  3. Release the Test button and immediately tap 3 times again. All the LEDs will flash Red quickly.
  4. When the LEDs stop flashing, the Main Repeater has been returned to factory settings

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
Radio RA2 Occupancy Sensors
Motion Sensor
Lutron Clear Connect

Factory Reset

  • Radio Powr Savr™ Occupancy/Vacancy Ceiling Sensor – 1st Generation (LRF2-xCRB-)
  1. Quickly tap 3 times and hold the Test, Lights ON, or Lights OFF button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the dome LED begins to flash slowly (approximately once per second).
  3. Release the button and tap it again 3 times until the dome LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.
  • Radio Powr Savr™ Occupancy/Vacancy Ceiling Sensor – 2nd Generation (LRF2- xCR2B-)
  1. Quickly tap 3 times and hold the Test or Light button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the dome LED begins to flash slowly (approximately once per second).
  3. Release the button and tap 3 times again until the dome LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.
  • Radio Powr Savr™ Occupancy/Vacancy Wall-Mounted Sensor
  1. Quickly triple tap and hold the Sensor, Lights ON, or Lights OFF button on the Sensor. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until the lens LED begins to flash slowly (approximately once per second).
  3. Release the button and tap it again 3 times until the lens LED on the Sensor flashes quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Sensor has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
Radio RA2 Select Main Repeater
RR-SEL-REP2
Repeater
Lutron Clear Connect

Factory Reset

  1. Quickly tap 3 times and hold down any button on the Main Repeater. DO NOT release after the third tap.
  2. Continue to hold the button for a few seconds. The Main Repeater LEDs will begin to flash Red slowly (approximately once per second).
  3. Release the button and quickly tap 3 times again. The Main Repeater LEDs will flash Green rapidly and then will reset, turning off all LEDs and then flashing the LEDs and beeping once. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The Main Repeater and system components have now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.
Brand
Device
Product Number
Device Type
Protocol
Lutron
RadioRA2 VCRX Visor Control Receiver
RR-VCRX
Garage Controller
Lutron Clear Connect

Factory Reset

  1. Quickly tap 3 times and hold any button (except Learn) on the VCRX. DO NOT release after third tap.
  2. Keep the button pressed after the third tap for a few seconds until all the status LEDs start to flash slowly (approximately once per second).
  3. Release the button and tap 3 times again until all the status LEDs on the VCRX flash quickly. (*Note* The time between release and the second triple tap must be less than half a second, thus must be performed very quickly).
  4. The VCRX has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.
Brand
Device
Product Number
Device Type
Protocol
Lutron
Serena Shades
Shade Control
Lutron Clear Connect

Factory Reset

  1. Tap the shade button quickly 3 times, and hold the shade button after the third tap until the shade button LED flashs Green rapidly.
  2. Immediately tap the shade button quickly 3 more times, until the shade button LED flashes Green rapidly, then flashes Red/Green 3 times, and turns off.
  3. The Serena shade has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device
Brand
Device
Product Number
Device Type
Protocol
Lutron
Sivoia QS Triathlon Shades
Shade Control
Lutron Clear Connect

Factory Reset

  1. Tap the shade button quickly 3 times, and hold the shade button after the third tap until the shade button LED flashs Green rapidly.
  2. Immediately tap the shade button quickly 3 more times, until the shade button LED flashes Green rapidly, then flashs Red/Green 3 times, and turns off.
  3. The Sivoia shade has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

Brand
Device
Product Number
Device Type
Protocol
Lutron
RadioRA2 Fan Control

RRD-2ANF

Fan Controller
Lutron Clear Connect

Factory Reset

  1. Tap the tapswitch 3 times on a control. DO NOT release after the third tap.
  2. Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until the LEDs on the dimmer start to scroll up and down quickly, or the LED on the switch flashes quickly
  3. Release the tapswitch and immediately tap it 3 times again.
  4. The LEDs on the dimmer will scroll up and down slowly and then the LED on the switch will flash slowly, indicating it has now been returned to Factory Default Settings.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device.
Brand
Device
Product Number
Device Type
Protocol
Lutron
Lutron Caséta Fan Control

PD-FSQN

Fan Controller
Lutron Clear Connect

Factory Reset

  1. Tap the "On" button quickly 3 times, holding on the last press.
  2. Continue to hold the "On" button until the light begins to flash quickly.
  3. Release the button, then immediately tap the button 3 more times.
  4. All paired Pico remote controls are removed and all settings are returned to factory default.

Join the Lutron Clear Connect network

  1. See the Lutron Integrator documentation.

Leaving the Lutron Clear Connect network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform a factory reset on the device

LUX

Brand
Device
Product Number
Device Type
Protocol
Lux
KONOz
Thermostat
Zigbee

Factory Reset

  1. Access the installation settings by going to the main menu and selecting the gear icon.
  2. You will see “IS” on the screen and will be prompted to select “yes” or “no”.
  3. Select “yes” to access the installation settings.
  4. Rotate the knob to view settings and press the knob to confirm.
  5. Once in the installer settings, rotate the knob to 99.
  6. Press the knob to confirm, then press and hold the knob for 3 seconds.

Join the Zigbee Network

  1. Perform factory reset.
  2. KONOz is now ready to be configured for your heating and cooling system. The KONOz will guide you through the initial system configuration.
  3. After confirming your system settings, KONOzwill ask if you would like to connect to a Smart Hub. Select “SET” to establish a connection.
  4. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Perform factory reset.

MCO Home

Brand
Device
Product Number
Device Type
Protocol
MCO Home
Dimmer Switch
MH-DT311
Dimmer
Z-Wave

Factory Reset

  1. Press 10 times of any button or exclude the device from Z-Wave network, then cut off the main power.
  2. The factory setting will be restored.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press 3 times on "+" or "-" button to add the device. If successful, the green LED flashes 4 times.
    • Note: If an external switch is wired to the dimmer, you may also toggle that 3 times to add the device to the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press 3 times on "+" or "-" button to exclude the device from the network. If successful, the green LED flashes 4 times.
    • Note: If an external switch is wired to the dimmer, you may also toggle that 3 times to add the device to the network.

Monoprice

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Door/Window Sensor

24259
Contact Sensor
Z-Wave Plus

Factory Reset

  1. To reset the sensor, press and hold the Z-button for about 20 seconds.
  2. The LED will change from steadily illuminated to flashing then back to steadily illuminated, indicating that the reset operation was successful.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Rapidly press the Z-button 3 times to include the device in the network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Rapidly press the Z-button 3 times to exclude the device from the network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Plug-In Dimmer

11994
Dimmer
Z-Wave

Factory Reset

  1. Ensure that the smart plug is inserted into an AC outlet.
  2. Press and hold the program button on the front for about 1 second to exclude the device, returning the device to a factory state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and hold the program button on the front for about 1 second to include the device in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the program button on the front for about 1 second to exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Plug-In ON/OFF

11995
Outlet
Z-Wave

Factory Reset

  1. Ensure that the smart plug is inserted into an AC outlet.
  2. Press and hold the program button on the front for about 1 second to exclude the device, returning the device to a factory state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and hold the program button on the front for about 1 second to include the device in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the program button on the front for about 1 second to exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Recessed Door/Window sensor

15268
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-button for 20 seconds and then release it. Your sensor will now be reset to its original settings

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-button on your sensor. If your sensor has been successfully linked to your network, its LED will turn solid for 2 seconds and then turn off.
  3. If linking was unsuccessful, the LED will continue to flash if you tap its button.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-button on your Sensor. If your switch has been successfully unlinked to your network, its LED will start to flash for a short time.
  4. If linking was unsuccessful, the LED will return to its last state. Tap the button to confirm if it has been unpaired, if unpaired successfully, the LED will flash when tapped.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Door/Window Sensor

15270
Contact Sensor
Z-Wave

Factory Reset

  1. Ensure that the smart plug is inserted into an AC outlet.
  2. Press and hold the program button on the front for about 1 second to exclude the device and return it to a factory state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and hold the program button on the front for about 1 second to include the device. The LED will stop flashing and glow steading to indicate the device has joined the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the program button on the front for about 1 second to exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

PIR Motion Sensor with Temperature

15271
Motion Sensor
Z-Wave

Factory Reset

  1. Ensure that the smart plug is inserted into an AC outlet.
  2. Press and hold the program button on the front for about 1 second to exclude the device and return it to a factory state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press and hold the program button on the front for about 1 second to include the device. The LED will stop flashing and glow steading to indicate the device has joined the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press and hold the program button on the front for about 1 second to exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Plug-in Outlet

15654
Outlet
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-button for 20 seconds and then release it. Your sensor will now be reset to its original settings

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. If the plug-in has not already been included into a Z-Wave network, the LED indicator will flash rapidly. Otherwise, the plug-in has already been included and must first be excluded before it can join the Hubitat Elevation™ Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click the Z-Button 3 times. The plug-in will be removed from your Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

4 in 1 motion sensor

15902
Motion Sensor
Z-Wave Plus

Factory Reset

  1. Press the program button, the LED will flash, indicating the sensor is no longer joined to the Z-Wave network and has returned it to a factory state.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Momentarily press the Program Switch
  3. The LED should flash 5 times indicating the sensor has not yet been included in the Z-Wave network.
  4. If the LED flashes only 1 time, then it has already been included in a Z-Wave network and must first be excluded before it may join the Hubitat Elevation™ Z-Wave network.
  5. Momentarily press the button again after it flashes 5 times, to automatically include the sensor in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the program button, the LED will flash, indicating the sensor is no longer joined to the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Monoprice

Smart Plug and Repeater

27481
Outlet
Z-Wave Plus

Factory Reset

  1. Ensure that the smart plug is inserted into an AC outlet.
  2. Press and hold the Z-Button on the smart plug for more than 20 seconds.
  3. The LED indicator will illuminate Yellow steadily for about 2 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Rapidly press the Z-button 3 times to include the device in the network.

Testing the Smart Plug Z-Wave connection

You can test the connectivity of the Z-Wave® network connection, with the RGB LED being used to indicate the connection quality.

To begin testing, press and hold the Z button for 6-9 seconds, releasing the button when the RGB LED illuminates violet.

  • Note: The smart plug must be included into a Z-Wave network to test the network connection. You can abort the test at any time by pressing the Z button.
    • Flashing Green: The RGB LED will flash Green while the smart plug is attempting to establish a connection with the main controller.
    • Solid Green: The RGB LED will illuminate Green for about 2 seconds to indicate that direct communications are stable.
    • Flashing Orange: The RGB LED will flash Orange while the smart plug is attempting to establish a connection with the main controller with intermediate radio transmitting power.
    • Solid Orange: The RGB LED will illuminate Orange for about 2 seconds to indicate that the communication quality is moderate.
    • Solid Red: The RGB LED will illuminate Red for about 2 seconds to indicate that they communications attempt has failed.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Rapidly press the Z-button 3 times to exclude the device from the network.
  4. The RGB LED will flash Orange while the smart plug is being removed.
  5. The smart plug will be removed from your Z-Wave network and the RGB LED will then illuminate Orange steadily for about 2 seconds.

NanoLeaf

Brand
Device
Product Number
Device Type
Protocol
NanoLeaf

Light Panels

Aurora / Canvas
Bulb
LAN

Factory Reset

  1. Disconnect power to the Nanoleaf Light Panels.
  2. Hold the Toggle and Power buttons together and reconnect the power without releasing the buttons.
  3. After about 7 seconds, the WiFi status LED will start to flash rapidly.
  4. Once the flashing begins, you can release the buttons.
  5. You must then wait 3 minutes for the Nanoleaf Light Panels to reset to factory default settings and boot-up.

Join the LAN

  1. Use the NanoLeaf Smarter Series app from your mobile device to setup your light panels on the WiFi network.
  2. From the Hubitat Web Interface home page, select Devices, then Add Virtual Device
  3. Name your device and select Nanoleaf Aurora from the device Type drop-down menu, and press Save.
  4. In the Preferences field of the driver, enter the IP address of your Nanoleaf panel.
    • NOTE: You should reserve the IP address for your NanoLeaf light panels in your router just as you do for your Hubitat Elevation™ hub. If you do not, the IP address will change when the DHCP lease on your router expires for connected IP devices. The result will be that the NanoLeaf Aurora driver will no longer be able to find your device.
  5. Press Save again in the driver.
  6. One your NanoLeaf panel, press the pairing button.
  7. In the NanoLeaf Aurora driver, press the Get Auth Token button.
  8. Test your panel for proper operation.

Leaving the LAN

  1. From the device's details page, select Remove Device, then Remove
  2. Plug your Light Panels into power. After a 1 minute bootup sequence the panels will show the last scene that was playing
  3. Press and hold down the Effect Select and Power buttons on the controller for about 10 seconds, until the LED on the controller begins flashing
  4. Release the two buttons and the LED on the controller will remain on and steady
  5. Delete the previous device from the app and setup once again

Neo

Brand
Device
Product Number
Device Type
Protocol
Neo

Door/Window Sensor

NAS-DS01ZE
Contact Sensor
Z-Wave

Factory Reset

  1. Remove tlease expires for the assigned IP address.
  2. he cover of contact sensor main body.
  3. Make sure the sensor is connected to power source.
  4. Press and hold the reset button for 10 seconds, the LED light will flash Red once.
  5. Release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the code button 3 times, the LED light will flash 5 times.
  3. The contact sensor will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the code button 3 times, the LED light will flash 5 times and the sensor will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Neo

Door/Window Sensor

NAS-DS02ZU
Contact Sensor
Z-Wave

Factory Reset

  1. Remove the cover of contact sensor main body.
  2. Make sure the sensor is connected to power source.
  3. Press and hold the reset button for 10 seconds, the LED light will flash Red once.
  4. Release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the code button 3 times, the LED light will flash 5 times.
  3. The contact sensor will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the code button 3 times, the LED light will flash 5 times and the sensor will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Neo

Motion Sensor

NAS-PD01ZU-T
Motion Sensor
Z-Wave

Factory Reset

  1. Remove the sensor’s cover.
  2. Make sure the sensor is connected to power source.
  3. Press the code button for 10 seconds, the LED will flash Red once.
  4. Release the code button.
    • NOTE: When the PIR is being restored to factory settings, please make sure a power source is connected.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the code button 3 times, the LED light will flash 5 times.
  3. The motion sensor will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the code button 3 times, the LED light will flash 5 times and the sensor will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Neo

Power Plug

NAS-WR02Z
Outlet
Z-Wave

Factory Reset

  1. Press and hold the code button on the front of the outlet for 10 seconds.
  2. When the LED flashes, release the button.
  3. When the outlet has been reset, the LED will flash on and off 5 times within a 2 second period.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the code button 3 times, the LED light will flash 5 times.
  3. The device will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the code button 3 times, the LED light will flash for 5 times and the device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Neo

One Key SOS

NAS-RC03ZU
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the code button for 10 seconds.
  2. Release the Code button. Note: Do not power off during factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the Red SOS alarm button 3 times.
  3. The device will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the Red SOS alarm button 3 times and the device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Neo

One Key SOS and Remote Control

NAS-RC03ZU
Button Controller
Z-Wave

Factory Reset

  1. Press and hold the code button for 10 seconds.
  2. Release the Code button. Note: Do not power off during factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly click the Red SOS alarm button 3 times.
  3. The device will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Quickly click the Red SOS alarm button 3 times and the device will be excluded from the Z-Wave network.

NodOn

Brand
Device
Product Number
Device Type
Protocol
NodOn

Octan Remote

CRC-3US-1
Button Controller
Z-Wave Plus

Factory Reset

  1. A simultaneous long press (1 second) on O and will perform this factory reset.
  2. The LED will flash red and green to validate the reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Simultaneously push on the solid circle and the + for 1 second.
  3. The LED glows in pink to confirm the selection
  4. Push on the solid circle within 10 seconds.
  5. The LED flashes in pink to confirm your choice and then flashes in green to confirm the procedure.
  6. The device will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Simultaneously push on the solid circle and the + for 1 second.
  4. The LED glows in pink to confirm the selection
  5. Push on the solid circle within 10 seconds.
  6. The LED flashes in pink to confirm your choice and then flashes in green to confirm the procedure
  7. The device will be excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
NodOn

Soft Remote

CRC-3US-6
Button Controller
Z-Wave Plus

Factory Reset

  1. A simultaneous long press (1 second) on O and will perform this factory reset.
  2. The LED will flash red and green to validate the reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Simultaneously push on the solid circle and the + for 1 second.
  3. The LED glows in pink to confirm the selection
  4. Push on the solid circle within 10 seconds.
  5. The LED flashes in pink to confirm your choice and then flashes in green to confirm the procedure.
  6. The device will be detected and included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Simultaneously push on the solid circle and the + for 1 second.
  4. The LED glows in pink to confirm the selection
  5. Push on the solid circle within 10 seconds.
  6. The LED flashes in pink to confirm your choice and then flashes in green to confirm the procedure
  7. The device will be excluded from the Z-Wave network.

NYCE

Brand
Device
Product Number
Device Type
Protocol
NYCE

Curtain Motion Sensor

NCZ-3045-HA
Motion Sensor
Zigbee

Factory Reset

  1. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  2. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  3. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  4. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  3. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Press the button 4 times to join the device to the Zigbee network.
  5. The LED will flash in the following sequences:
    • Yellow - Red - Yellow flashes indicate it is searching for a network to join.
    • Yellow - Green - Yellow flashes indicate the device is being configured.
    • 3 Green flashes indicate the device has successfully joined the network.
    • 3 Red flashes indicate the devices failed to join the network. If this happens, ensure a factory reset has been performed and repeat the process from step 4.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  3. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  5. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Brand
Device
Product Number
Device Type
Protocol
NYCE

Ceiling Motion Sensor

NCZ-3043-HA
Motion Sensor
Zigbee

Factory Reset

  1. Remove the Mounting Plate by rotating the Housing counter-clockwise as shown.
  2. Inside the battery compartment is a small button on the side of the circuit board.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  3. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  4. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the Mounting Plate by rotating the Housing counter-clockwise as shown.
  3. Inside the battery compartment is a small button on the side of the circuit board.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Press the button 4 times to join the device to the Zigbee network.
  5. The LED will flash in the following sequences:
    • Yellow - Red - Yellow flashes indicate it is searching for a network to join.
    • Yellow - Green - Yellow flashes indicate the device is being configured.
    • 3 Green flashes indicate the device has successfully joined the network.
    • 3 Red flashes indicate the devices failed to join the network. If this happens, ensure a factory reset has been performed and repeat the process from step 4.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Remove the Mounting Plate by rotating the Housing counter-clockwise as shown.
  3. Inside the battery compartment is a small button on the side of the circuit board.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  5. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Brand
Device
Product Number
Device Type
Protocol
NYCE

Motion Sensor

NCZ-3041-HA
Motion Sensor
Zigbee

Factory Reset

  1. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  2. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  3. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  4. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  3. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Press the button 4 times to join the device to the Zigbee network.
  5. The LED will flash in the following sequences:
    • Yellow - Red - Yellow flashes indicate it is searching for a network to join.
    • Yellow - Green - Yellow flashes indicate the device is being configured.
    • 3 Green flashes indicate the device has successfully joined the network.
    • 3 Red flashes indicate the devices failed to join the network. If this happens, ensure a factory reset has been performed and repeat the process from step 4.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. To open the battery cover, use a flathead screwdriver in the recessed slot at the bottom of the sensor housing.
  3. Inside the battery compartment at the top, is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  5. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Brand
Device
Product Number
Device Type
Protocol
NYCE

Garage Door (Tilt) Sensor

NCZ-3014-HA
Contact Sensor
Zigbee

Factory Reset

  1. Slide open the Garage Door (Tilt) Sensor’s top housing.
  2. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  3. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  4. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide open the Garage Door (Tilt) Sensor’s top housing.
  3. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Press the button 4 times to join the device to the Zigbee network.
  5. The LED will flash in the following sequences:
    • Yellow - Red - Yellow flashes indicate it is searching for a network to join.
    • Yellow - Green - Yellow flashes indicate the device is being configured.
    • 3 Green flashes indicate the device has successfully joined the network.
    • 3 Red flashes indicate the devices failed to join the network. If this happens, ensure a factory reset has been performed, and repeat the process from step 4.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Slide open the Garage Door (Tilt) Sensor’s top housing.
  3. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  5. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Brand
Device
Product Number
Device Type
Protocol
NYCE

Door/Window Sensor

NCZ-3011-HA
Contact Sensor
Zigbee

Factory Reset

  1. Slide open the Door/Window Sensor’s top housing.
  2. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  3. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  4. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide open the Door/Window Sensor’s top housing.
  3. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Press the button 4 times to join the device to the Zigbee network.
  5. The LED will flash in the following sequences:
    • Yellow - Red - Yellow flashes indicate it is searching for a network to join.
    • Yellow - Green - Yellow flashes indicate the device is being configured.
    • 3 Green flashes indicate the device has successfully joined the network.
    • 3 Red flashes indicate the devices failed to join the network. If this happens, ensure a factory reset has been performed, and repeat the process from step 4.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Slide open the Door/Window Sensor’s top housing.
  3. Inside the battery compartment is a small button.
    • Note: The button may be pressed with the end of a paper clip or a pencil. Do not use a sharp object like a tack or pin.
  4. Pressing the button 10 times will leave the network and reset the device to factory defaults.
  5. The LED will flash Red 3 times to indicate is has left the network (If joined), and it will flash Green 5 times to indicate defaults have been restored.

Orbit

Brand
Device
Product Number
Device Type
Protocol
Orbit

Smart Hose Faucet Timer

27087
Irrigation Controller
Zigbee

Factory Reset

  1. Insert two AA alkaline batteries and re-insert the tray.
  2. Press the RESET button 5 times in rapid secession.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide out the battery tray on the back of the timer.
  3. Insert two AA alkaline batteries and re-insert the tray.
    • NOTE: Firmly replace the battery tray to ensure water resistance and increase battery life. You will know the battery tray is fully inserted if it does not pull out easily.
  4. Turn the dial to AUTO.
  5. When batteries are inserted, the timer will automatically attempt to connect and the wireless icon on screen will begin to flash.
    • NOTE: The timer will remain in pairing mode for 10 minutes or until paired. If pairing is not successful after 10 minutes, the timer will stop trying to pair. To enter pairing mode again press the RESET button 5 times in rapid secession.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove
  2. Press the RESET button 5 times in rapid secession.

Brand
Device
Product Number
Device Type
Protocol
Orbit

12-Station Sprinkler Controller

27396
Irrigation Controller
Zigbee

Factory Reset

  1. Ensure the controller is connected to power.
  2. Press the SYNC button 5 times in rapid secession.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Ensure the controller is connected to power.
  3. Turn the dial to AUTO.
  4. When the controller is first connected to power, it will automatically attempt to connect.
    • NOTE: If pairing is not successful after 10 minutes, the controller will stop trying to pair. To re-enter pairing mode, push the 'SYNC' button 5 times in rapid succession
  5. The wireless icon will flash until the controller is paired. Once paired, the wireless icon will remain solid, and the words SMART MODE will appear on the screen.
  6. Wait for the device to be added into the system, successful pairing will be confirmed by Hubitat Elevation™
  7. Watch the status in the device details page to confirm proper operation

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the RESET button 5 times in rapid secession. The device will try to re-connect again, so you will need to let it time out or hold the SYNC button for 5 seconds to cancel re-pairing.

Orvibo

Brand
Device
Product Number
Device Type
Protocol
Obvibo
Motion Sensor
SN11
Motion Sensor
Zigbee

Factory Reset

  1. Hold down the reset button on the front of the motion sensor until the Green light goes out.
  2. This will disconnect the sensor from the Zigbee network.
  3. Short-press the reset button and the Green light will flash slowly.
  4. The sensor is now in pairing mode.

Join the Zigbee Network

  1. Remove the cover by rotating it counterclockwise
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Hold down the reset button on the front of the motion sensor until the Green light goes out.
  4. This will disconnect the sensor from the Zigbee network.
  5. Short-press the reset button and the Green light will flash slowly.
  6. The sensor is now in pairing mode.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold down the reset button on the front of the motion sensor until the Green light goes out.
  3. This will disconnect the sensor from the Zigbee network.

OSRAM

Brand
Device
Product Number
Device Type
Protocol
Osram
Lightify Flex RGBW
73698
Bulb
Zigbee

Factory Reset

  1. Start with the Light Strip powered ON.
  2. Repeat 5 times - Unplug for 1 second and then plug in for 1 second
  3. On the fifth time plugging in the Light Strip, leave it plugged in
  4. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset and ready for pairing.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Start with the Light Strip powered ON.
  3. Repeat 5 times - Unplug for 1 second and then plug in for 1 second
  4. On the fifth time plugging in the Light Strip, leave it plugged in
  5. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset and ready for pairing.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Start with the Light Strip powered ON.
  3. Repeat 5 times - Unplug for 1 second and then plug in for 1 second
  4. On the fifth time plugging in the Light Strip, leave it plugged in
  5. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset and ready for pairing.

Brand
Device
Product Number
Device Type
Protocol
Osram
All smart bulbs
Bulb
Zigbee

Factory Reset

  1. Turn the light off
  2. Turn the light on for three 3 seconds
  3. Turn the light off
  4. Repeat this cycle 5 times
  5. Wait 10 seconds for the light to flash 3 times
  6. Repeat these steps if the light does not flash three times

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn the light off
  3. Turn the light on for three 3 seconds
  4. Turn the light off
  5. Repeat this cycle 5 times
  6. Wait 10 seconds for the light to flash 3 times
  7. Repeat these steps if the light does not flash 3 times

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Turn the light off
  3. Turn the light on for three 3 seconds
  4. Turn the light off
  5. Repeat this cycle 5 times
  6. Wait 10 seconds for the light to flash 3 times
  7. Repeat these steps if the light does not flash 3 times

Brand
Device
Product Number
Device Type
Protocol
Osram
Smart Outdoor Plug
G11028081
Outlet
Zigbee

Factory Reset

NOTE: Reset method may vary by firmware version

Method 1

  1. Hold the button for 30 seconds
  2. The outdoor plug will click 5 times
  3. The outdoor plug is now reset and ready for pairing

Method 2

  1. Turn the outdoor plug off
  2. Turn the outdoor plug on for three 5 seconds
  3. Turn the outdoor plug off
  4. Repeat this cycle 5 times
  5. The outdoor plug is now reset and ready for pairing

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. See factory reset instructions above to reset the outdoor plug and ready it for pairing . The required steps will vary by firmware version.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. See factory reset instructions above. The required steps will vary by firmware version.

Philips Hue

Brand
Device
Product Number
Device Type
Protocol
Philips Hue
Smart Button
046677553715
Button Controller
Zigbee

Factory Reset

  1. Turn the smart button over and remove the back cover. Use a straightened paperclip to press the setup button on the back for 5 seconds. An LED on the front of the sensor will flash once to confirm factory reset.

Join the Zigbee Network

  1. Turn the smart button over and remove the back cover. Use a straightened paperclip to press the setup button on the back for 5 seconds. An LED on the front of the sensor will flash once to confirm reset.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press the button until the LED on the front of the button is flashing.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Turn the smart button over and remove the back cover. Use a straightened paperclip to press the setup button on the back for 5 seconds. An LED on the front of the sensor will flash once to confirm factory reset.

Brand
Device
Product Number
Device Type
Protocol
Philips Hue
Dimmer Switch
73698
Button Controller
Zigbee

Factory Reset

  1. Turn the dimmer switch over and use a straightened paperclip to press the setup button on the back for 1 second.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn the dimmer switch over and use a straightened paperclip to press the setup button on the back for 1 second.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Turn the dimmer switch over and use a straightened paperclip to press the setup button on the back for 1 second.

Brand
Device
Product Number
Device Type
Protocol
Philips Hue
Motion Sensor

473389

Motion Sensor
Zigbee

Factory Reset

  1. On the back of the motion sensor, and use a straightened paperclip to press the setup button for 1 second.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. On the back of the motion sensor, and use a straightened paperclip to press the setup button for 1 second.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. On the back of the motion sensor, and use a straightened paperclip to press the setup button for 1 second.

Brand
Device
Product Number
Device Type
Protocol
Philips Hue
Smart Plug

046677552343

Outlet
Zigbee

Factory Reset

  1. Press the power button for 10 seconds.

Join the Zigbee Network

  1. Press the power button for 10 seconds to factory reset the smart plug.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the power button for 10 seconds.

Brand
Device
Product Number
Device Type
Protocol
Philips Hue
All Hue Lights
Bulb
Zigbee

Factory Reset

  1. You must use a Hue Dimmer to factory reset a Hue bulb, light fixture or LED strip that is not attached to a Hue bridge.
  2. Turn on the light on to be reset, ensuring other bulbs within a few inches are unscrewed or unplugged or they may be reset too.
  3. Hold the remote within 4 inches of the light.
  4. Press and hold the 1st (On / I in some countries) and the and 4th (Off / O in some countries) buttons simultaneously for about 10 seconds, until the light starts flashing on and off.
  5. When the light stops flashing, it will remain ON at full brightness, and the green LED on the remote will flash green, indicating the bulb has been factory reset.

Join the Zigbee Network

  1. Using a Hue dimmer, factory reset the light as described above.
  2. Disconnect the light from mains power.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  4. Power on the light

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Using a Hue dimmer, factory reset the light as described above.

Powerly

Brand
Device
Product Number
Device Type
Protocol
Powerly
Thermostat
Thermostat
Z-Wave

Factory Reset

  1. To reset to factory defaults, turn the thermostat off by pressing Mode repeatedly until OFF scrolls across the display.
  2. Press and hold the down and up Setpoint arrows at the same time for 5 seconds.
  3. If successful, RESET will scroll across the display and the device will be restored to its default settings.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. To put your thermostat into inclusion mode, press and hold Mode for 5 seconds.
  3. CONNECT will scroll across the thermostat display once in inclusion mode.
  4. SUCCESS will scroll across the thermostat display once included, but FAIL will scroll across the thermostat display if inclusion is unsuccessful,

Exclusion from the Z-Wave Network

  1. To exclude your Thermostat, press and hold Mode for 5 seconds to initiate the Z-Wave exclusion process.
  2. DELETE will scroll across the thermostat display once in exclusion mode. If you need to cancel the exclusion process, press Mode.
  3. To complete exclusion, press either the up or down arrow.
  4. SUCCESS will scroll across the thermostat display once excluded.

Qubino

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush 1 Relay
ZMNHAD3
Relay
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 5 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 5 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush 1D Relay
ZMNHND3
Relay
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 5 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush 2 Relay
ZMNHBD3
Relay
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush Shutter DC
ZMNHOD3
Relay
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds.

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush Shutter
ZMNHCD3
Relay
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush ON/OFF Thermostat
ZMNHID3
Thermostat
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 5 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds

Brand
Device
Product Number
Device Type
Protocol
Qubino
Flush Dimmer
ZMNHDD3
Dimmer
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds (5 times change switch state).
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button for more than 6 seconds.
  • NOTE: By resetting the device, all custom parameters previously set on the device will return to their default values, and the owner ID will be deleted.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply (with the temperature sensor already connected*).
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds. The device has to get On/Off signal 3 times, meaning 3 times push on the push button or 6 times flip of a switch.
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between 2-6 seconds
  • NOTE: *If connecting the temperature sensor, switch off the power supply and make sure the device is excluded from your network BEFORE connecting the sensor

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds
    • If the device is powered by 24 V SELV supply, press and hold the S (Service) button between

Brand
Device
Product Number
Device Type
Protocol
Qubino
Mini Dimmer
ZMNHHD3
Dimmer
Z-Wave Plus

Factory Reset

  1. Connect the device to the power supply.
  2. Within the first 60 seconds the device is connected to the power supply, toggle the switch connected to the I1 terminal 5 times within 3 seconds.
  3. Alternatively, press and hold the S (Service) button for at least 6 seconds if connected to 24-30VDC

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Connect the device to the power supply.
  3. Toggle the switch connected to the I1 terminal 3 times within 3 seconds (this procedure puts the device in LEARN MODE).
  4. Alternatively, press and hold the S (Service) button between 2~6 seconds if connected to 24-30VDC to put the device in LEARN MODE).
  • NOTE: Inclusion with the switch connected to I1 terminal is not limited by time.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Connect the device to the power supply.
  4. Toggle the switch connected to the I1 terminal 3 times within 3 seconds (this procedure puts the device in LEARN MODE).
  5. Alternatively, press and hold the S (Service) button between 2~6 seconds if connected to 24-30VDC to put the device in LEARN MODE).
  • NOTE: Exclusion with the switch connected to I1 terminal is not limited by time.

Quotra

Brand
Device
Product Number
Device Type
Protocol
Quotra
Wireless Smart Dimmer

B07CVL9SZF

Dimmer
Zigbee

Factory Reset

  1. Press and hold the power button for 10 seconds.
  2. Rlease when the LED slowly fades in and out (this will only happen for 3 seconds).

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button for 10 seconds.
  3. Rlease when the LED slowly fades in and out (this will only happen for 3 seconds).

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the power button for 10 seconds.
  3. Rlease when the LED slowly fades in and out (this will only happen for 3 seconds).

Radio Thermostat Company of America

Brand
Device
Product Number
Device Type
Protocol
Radio Thermostat Company of America
Thermostat
CT-101
Thermostat
Z-Wave

Factory Reset

  1. The thermostat must be in OFF mode.
  2. Wait until the radio wave icons on the left side of the screen stop flashing then touch the screen once to turn on the back light and then hold the center of the screen for about 8 seconds until the thermostat beeps.

Factory Reset (Alternate Method)

  1. Place the CT101 in the off position by pressing mode button until OFF is shown at the top left of the screen.
  2. Press the menu button
  3. Press and hold the center of the screen for about 5 sec or until the screen changes then release.
  4. You will see two arrows. First press the up arrow and wait for the count down.
  5. Now press the down arrow and again, wait for the count down.
  6. All parameter values will be restored to defaults and a message is sent to any radio module installed to instruct the module to restore its own default values.
    • The thermostat will now resets itself.
  7. Press the house to get back to the main screen.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  3. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will flash.
  4. When a device has joined a network the LINK icon will appear under the radio tower.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press/Touch the MATE button on the MENU screen. A large r1 will be displayed.
  4. This will bring you to the network include screen. Confirm by touching MATE again to initiate the mating process. The MATE icon and the status indicator LEDs will flash.
  5. When a device has excluded from the network, the LINK icon will disappear under the radio tower.

Remotec

Brand
Device
Product Number
Device Type
Protocol
Remotec
Relay / Fixture Switch
ZFM-80US/DA065
Relay
Z-Wave

Factory Reset

  1. Factory reset is accomplished by excluding the device from the Z-Wave netowrk
  2. From the device's details page, select Remove Device, then Remove
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Click once on the PROG button or and external attached switch.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Click once on the PROG button or and external attached switch.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click once on the PROG button or and external attached switch.

Brand
Device
Product Number
Device Type
Protocol
Remotec
ZRC-90 Scene Master
REMEZRC90
Button Controller
Z-Wave Plus

Factory Reset

  1. Press and keep holding R button not less than 10 seconds.
  2. Release R button then triple click on the same R button within 2 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press L & R buttons simultaneously until the LED lights up to add the device to the Z-Wave network. The LED will keep flashes slowly.
  3. Press the program button. The LED will flash once, then remain off if the device is included into the Z-Wave network.
  4. If the LED flashes 6 times rapidly, then remains off, the device has failed to be included in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Click once on the R button to remove the device from the Z-Wave network. The LED will continue flashing slowly.
  4. Press the program button. The LED will flash once, then remain off if the device is excluded from the Z-Wave network.
  5. If the LED flashes 6 times rapidly, then remains off, the device has failed to be excluded in the Z-Wave network.
  6. Perform a factory reset and repeat the above steps to exclude the device from the Z-Wave network.

RGBgenie

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
4 Channel Dimming Controller
ZB-1003
Dimmer
Zigbee

Factory Reset

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash quickly and then stay in a slow rhythmic breathing pattern to indicate a successful reset.

Join the Zigbee Network

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash quickly and then stay in a slow rhythmic breathing pattern to indicate a successful reset and the device is ready for pairing.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
RGBW Color controller
ZB-1025
Dimmer
Zigbee

Factory Reset

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. Press the program button quickly 5 times, or if the unit is not accessible, power the device off and on quickly 5 times.
  2. The LED will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.
  3. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Single color remote
ZW-5121
Button Controller
Zigbee

Factory Reset

  1. Press and hold the middle (Light ON) button.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the middle (Light ON) button.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the middle (Light ON) button.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
RGB color remote
ZW-5122
Button Controller
Zigbee

Factory Reset

  1. Press and hold the middle (Light ON) button.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the middle (Light ON) button.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the middle (Light ON) button.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Monochrome controller panel
ZB-3026
Button Controller
Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Single Channel Trailing Edge Dimmer
ZB-4002
Dimmer
Zigbee

Factory Reset

  1. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Single Channel Micro Controller and Lamp Module
ZB-4003
Switch
Zigbee

Factory Reset

  1. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Short press the Reset button 5 times in a row, or if the button is not accessible, power cycle the device 5 times.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
3 Zone Color Touch Panel
ZB-5027
Button Controller
Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Color Remote
ZB-5028
Button Controller
Zigbee

Factory Reset

  1. Press and hold down the power button on the Touch Panel until the LED indicator turns on.
  2. Immediately press the power button 5 times.
  3. The LED indicator will flash 3 times quickly to indicate successful removal from the network and is now reset to factory default.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button until the LED status indicator turns on.
  3. Immediately press the S1 button once to enable the Touch Panel to search for nearby networks. The LED indicator will flash once every second.

Verifying network pairing

  1. Quickly press any button and the LED indicator should flash once.
  2. If the LED indicator does not respond, the Touch Panel is not paired with a network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
RGBW Color controller
ZW-1001
Dimmer
Z-Wave Plus

Factory Reset

  1. Press and hold down Inclusion/Exclusion button for over 10 seconds
  2. The connected LED light will stays ON solid for 3 seconds to indicate successful factory reset
  3. Release Inclusion/Exclusion button and all 4 PWM outputs will restore to 50% brightness.

Join the Z-Wave Network

  1. Power on the LED dimmer
  2. If the connected LED light has a solid ON status, it means the LED dimmer has already been included into a network and you first you have to set the LED dimmer into Exclusion mode.
  3. Once excluded, it will be set into Inclusion mode automatically, and waiting to be included in the Z-Wave network.
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple press the “inclusion/exclusion” button
  4. The LED dimmer will be set to Exclusion mode and the connected LED light will flash quickly for 6 seconds
  5. The LED light will stay ON solid for 3 seconds to indicate successful exclusion.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
RGBW Color controller
ZW-1002
Dimmer
Z-Wave Plus

Factory Reset

  1. Press and hold down Inclusion/Exclusion button for over 10 seconds
  2. The connected LED light will stays ON solid for 3 seconds to indicate successful factory reset
  3. Release Inclusion/Exclusion button and all 4 PWM outputs will restore to 50% brightness.

Join the Z-Wave Network

  1. Power on the LED dimmer
  2. If the connected LED light has a solid ON status, it means the LED dimmer has already been included into a network and you first you have to set the LED dimmer into Exclusion mode.
  3. Once excluded, it will be set into Inclusion mode automatically, and waiting to be included in the Z-Wave network.
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Triple press the “inclusion/exclusion” button
  4. The LED dimmer will be set to Exclusion mode and the connected LED light will flash quickly for 6 seconds
  5. The LED light will stay ON solid for 3 seconds to indicate successful exclusion.

Brand
Device
Product Number
Device Type
Protocol
RGBgenie
Micro controller and Lamp Module
ZW-4001
Dimmer
Z-Wave Plus

Factory Reset

  1. Press and hold down Reset button for over 10 seconds

Join the Z-Wave Network

  1. Power on the micro controller
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the Reset button 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Reset button 3 times quickly.

Ring

Brand
Device
Product Number
Device Type
Protocol
Ring
Ring Alarm Range Extender v1
4AR1S70EN0
Repeater
Z-Wave Plus

Factory Reset

  1. Plug in the Range Extender.
  2. Press and hold the button on the right side of the device. The LED on the device will flash rapidly.
  3. When the LED begins to flash slowly, release the button.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave on the Device Discovery page to start device discovery.
  2. Press the button on the right side of the device to begin Inclusion to the Z-Wave network.

Leaving the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the button on the right side of the device to Exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Ring
Ring Alarm Contact Sensor v1
4SD1S70EN0
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Open the contact sensor cover.
  2. Remove the battery from the device.
  3. Press and hold the tamper switch while reinstalling the battery.
  4. The LED will be flashing. Keep holding the tamper switch until the LED turns off.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave on the Device Discovery page to start device discovery.
  2. Open the contact sensor cover.
  3. Quickly remove and replace the battery to begin Inclusion to the Z-Wave network.

Leaving the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Open the contact sensor cover.
  3. Quickly remove and replace the battery to Exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Ring
Ring Alarm Motion Sensor v1
4SP1S70EN0
Motion Sensor
Z-Wave Plus

Factory Reset

  1. Insert a straightened paper clip into the pinhole at the back of the motion detector.
  2. Press and hold the reset button.
  3. The LED will be flashing. Keep holding the reset button until the LED turns off.
  4. Open the motion sensor cover.
  5. Quickly remove and replace the battery to complete factory reset of the device.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave on the Device Discovery page to start device discovery.
  2. Open the motion sensor cover.
  3. Quickly remove and replace the battery to begin Inclusion to the Z-Wave network.

Leaving the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Open the motion sensor cover.
  3. Quickly remove and replace the battery to Exclude the device from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Ring
Ring Alarm Smoke/CO Listener
4SS1S80EN0
Smoke/CO Detector
Z-Wave Plus

Factory Reset

  1. Press and hold the setup button on the side of the device for 10 seconds.
  2. When the LED stops flashing, the device has been factory reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave on the Device Discovery page to start device discovery.
  2. Open the Smoke/CO Listener cover.
  3. Quickly remove and replace the battery.
  4. Press the setup button on the side of the device to begin Inclusion to the Z-Wave network.

Leaving the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Open the Smoke/CO Listener cover.
  3. Quickly remove and replace the battery.
  4. Press the setup button on the side of the device to Exclude it from the Z-Wave network.

SAGE

Brand
Device
Product Number
Device Type
Protocol
SAGE
Doorbell Sensor
Doorbell Sensor
Zigbee

Factory Reset

  1. Remove the plastic cover and the battery.
  2. Press and hold the tiny RESET button (next to where the wires attach to the circuit board) while you reinstall the battery.
  3. Continue holding RESET until the Red LED flashes.

Join the Zigbee Network

  1. Remove the plastic cover and the battery.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press and hold the tiny RESET button (next to where the wires attach to the circuit board) while you reinstall the battery.
  4. Continue holding RESET until the Red LED flashes.
  5. If the device is not discovered by Hubitat Elevation™, then move the device closer to the hub and try again. It should now be discovered by the hub.

Leaving the Zigbee Network

  1. Remove the plastic cover and the battery.
  2. From the device's details page, select Remove Device, then Remove.
  3. Press and hold the tiny RESET button (next to where the wires attach to the circuit board) while you reinstall the battery.
  4. Continue holding RESET until the Red LED flashes.

Brand
Device
Product Number
Device Type
Protocol
SAGE
Light Switch Controller
Light Switch Controller
Zigbee

Factory Reset

  1. Remove the battery from the light switch.
  2. Press and hold the rocker switch in the ON position as you reinstall the battery.
  3. Continue to hold the switch in the ON position until the Red LED flashes.

Join the Zigbee Network

  1. Remove the battery from the light switch.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press and hold the rocker switch in the ON position as you reinstall the battery.
  4. Continue to hold the switch in the ON position until the Red LED flashes.
  5. If the device is not discovered by Hubitat Elevation™, then move the device closer to the hub and try again. It should now be discovered by the hub.

Leaving the Zigbee Network

  1. Remove the battery from the light switch.
  2. From the device's details page, select Remove Device, then Remove.
  3. Press and hold the rocker switch in the ON position as you reinstall the battery.
  4. Continue to hold the switch in the ON position until the Red LED flashes.

Salus

Brand
Device
Product Number
Device Type
Protocol
Salus
Smart Plug
SP-600
Outlet
Zigbee

Factory Reset

  1. Press the button on the outlet for 10 seconds.
  2. The light surrounding the button will flash Red 5 times, and will then go out.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press the button on the outlet for 10 seconds.
  3. The light surrounding the button will flash Red 5 times, and will then go out.
  4. If the device is not discovered by Hubitat Elevation™, then unplug the outlet for 10 seconds and plug it in again. It should now be discovered by the hub.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the button on the outlet for 10 seconds.
  3. The light surrounding the button will flash Red 5 times, and will then go out.

Samsung SmartThings

Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Outlet 2017
F-OUT-US-2
Outlet
Zigbee

Factory Reset

  1. Hold the Connect button for 5 seconds, and release it when the LED starts flashing Blue.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Make sure the Outlet is within 15 feet (4.5 meters) of the hub during setup.
  3. Hold the Connect button for 5 seconds, and release it when the LED starts flashing Blue.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button for 5 seconds, and release it when the LED starts flashing Blue.

Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Outlet V5
IM6001-OTP
Outlet
Zigbee

Factory Reset

  1. Hold the Connect button for 5 seconds, and release it when the LED flashes Blue 3 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the Connect button for 5 seconds, and release it when the LED flashes Blue 3 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button for 5 seconds, and release it when the LED flashes Blue 3 times.
Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Button V5
IM6001-BTP
Button
Zigbee

Factory Reset

  1. Hold the recessed connect button for 5 seconds.
  2. Release the button when the LED starts flashing Red.
  3. The LED will flash Red and Green while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.
  4. The LED will flash Red and Green while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Motion Sensor V5
IM6001-MTP
Motion Sensor
Zigbee

Factory Reset

  1. Hold the recessed connect button for 5 seconds.
  2. Release the button when the LED starts flashing Red.
  3. The LED will flash red and green while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.
  4. The LED will flash Red and Green while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Water Leak Sensor V5
IM6001-WLP
Water Sensor
Zigbee

Factory Reset

  1. Hold the recessed connect button for 5 seconds.
  2. Release the button when the LED starts flashing Red.
  3. The LED will flash Red and Green while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.
  4. The LED will flash Red and Green while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
Samsung SmartThings
Multi Sensor V5
IM6001-MPP
Contact Sensor
Zigbee

Factory Reset

  1. Hold the recessed connect button for 5 seconds.
  2. Release the button when the LED starts flashing Red.
  3. The LED will flash red and green while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.
  4. The LED will flash Red and Green while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.

Schlage

Brand
Device
Product Number
Device Type
Protocol
Schlage
LiNK Deadbolt
BE-369
Lock
Z-Wave

Factory Reset

  1. Disconnect the 9V battery.
  2. On the lock keypad, press and release the Schlage button.
  3. Reconnect the battery and wait until the Schlage button is no longer lit.
  4. Within 10 seconds, press and hold the Schlage button until it lights Green and the lock beeps.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Enter the 6 digit programming code.
  3. Wait for the Schlage button will flash Amber 3 times. It will be accompanied by 3 beeps.
  4. Press the Schlage button and the 0 key.
  5. If successful, the Schlage button will be flashing Amber.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Enter the 6 digit programming code.
  4. Wait for the Schlage button will flash Amber 3 times. It will be accompanied by 3 beeps.
  5. Press the Schlage button and the 0 key.
  6. If successful, the Schlage button will be flashing Amber.

Brand
Device
Product Number
Device Type
Protocol
Schlage
LiNK Deadbolt
FE-599
Lock
Z-Wave

Factory Reset

  1. Disconnect the 9V battery.
  2. On the lock keypad, press and release the Schlage button.
  3. Reconnect the battery and wait until the Schlage button is no longer lit.
  4. Within 10 seconds, press and hold the Schlage button until it lights Green and the lock beeps.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Enter the 6 digit programming code.
  3. Wait for the Schlage button will flash Amber 3 times. It will be accompanied by 3 beeps.
  4. Press the Schlage button and the 0 key.
  5. If successful, the Schlage button will be flashing Amber.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Enter the 6 digit programming code.
  4. Wait for the Schlage button will flash Amber 3 times. It will be accompanied by 3 beeps.
  5. Press the Schlage button and the 0 key.
  6. If successful, the Schlage button will be flashing Amber.

Brand
Device
Product Number
Device Type
Protocol
Schlage
Connect Deadbolt
BE-468 / BE-469
Lock
Z-Wave

Factory Reset

  1. Disconnect the batteries
  2. Press and hold the outside Schlage button
  3. While holding the outside Schlage button, then reconnect the batteries.
  4. Release the Outside Schlage Button. NOTE: If you are moving the lock to a new door, install the lock on that door before continuing.
  5. To check that the lock was reset, press the outside Schlage button and enter one of the Default User Codes.
  6. If the reset was successful, the lock will perform a setup routine. Wait until the bolt stops moving. The reset and setup are complete.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Schlage button.
  3. Enter the 6 digit programming code.
  4. Press 0
  5. A indicates the lock successfully joined the Z-Wave network, while an X indicates that it did not successfully join the network.

Verify Z-Wave connection status from the lock

  1. Remove the battery cover.
  2. Disconnect the battery connector.
  3. While watching the inside Schlage button, reconnect the battery connector.
  4. The inside Schlage button will flash if the lock is enrolled.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Schlage button.
  4. Enter the 6 digit programming code.
  5. Press 0
  6. A indicates the lock was successfully excluded the Z-Wave network, while an X indicates that it did not successfully leave the network.

Sengled

Brand
Device
Product Number
Device Type
Protocol
Sengled
Element Bulbs
Bulb
Zigbee

Factory Reset

  1. Power cycle on and off 15 times, VERY quickly, ending on the ON position.
    • NOTE: An on and off cycle counts as 1
  2. If successful, the bulb will flash 5 times, and will then be in pairing mode.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Power cycle on and off 15 times, VERY quickly, ending on the ON position.
    • NOTE: An on and off cycle counts as 1
  3. If successful, the bulb will flash 5 times, and will then be in pairing mode.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Power cycle on and off 15 times, VERY quickly, ending on the ON position.
    • NOTE: An on and off cycle counts as 1
  3. If successful, the bulb will flash 5 times, and will then be in pairing mode.

Brand
Device
Product Number
Device Type
Protocol
Sengled
Smart Window and Door Sensor

E1D-G73WNA

Contact Sensor
Zigbee

Factory Reset

  1. To reset the sensor, use the provided tool, or something equally thin like a paper clip.
  2. Press and hold the reset button inside the unit for 8 seconds.
  3. If successful, a Red light on the face of the sensor will flash 2 times.
    • NOTE: After the sensor is reset, you will have one minute to add it to your hub.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. To reset the sensor, use the provided tool, or something equally thin like a paper clip.
  3. Press and hold the reset button inside the unit for 8 seconds.
  4. If successful, a Red light on the face of the sensor will flash 2 times.
    • NOTE: After the sensor is reset, you will have one minute to add it to your hub.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. To reset the sensor, use the provided tool, or something equally thin like a paper clip.
  3. Press and hold the reset button inside the unit for 8 seconds.
  4. If successful, a Red light on the face of the sensor will flash 2 times.
    • NOTE: After the sensor is reset, you will have one minute to add it to your hub.

Brand
Device
Product Number
Device Type
Protocol
Sengled
Multi-Color Light Strip

E1G-G8E

Bulb
Zigbee

Factory Reset.

  1. Press and hold the reset button inside the unit for 10 seconds.
  2. If successful, the light strip will flash 5 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the reset button inside the unit for 10 seconds.
  3. If successful, the light strip will flash 5 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the reset button inside the unit for 10 seconds.
  3. If successful, the light strip will flash 5 times.

Brand
Device
Product Number
Device Type
Protocol
Sengled
Smart Plug

E1C-NB6

Outlet
Zigbee

Factory Reset.

  1. Press and hold the power button for 15 seconds.
  2. If successful Blue indicator light will stay on briefly, and then slowly pulse on and off.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold the power button for 15 seconds.
  3. If successful Blue indicator light will stay on briefly, and then slowly pulse on and off.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold the power button for 15 seconds.
  3. If successful Blue indicator light will stay on briefly, and then slowly pulse on and off.

Sensative

Brand
Device
Product Number
Device Type
Protocol
Sensative Strips
Guard
Contact Sensor
Z-Wave Plus

Factory Reset

  1. Move magnet all the way to the rounded edge, You should see 1 short LED flash.
  2. Move magnet towards center 2 times. You should see 2 LED flashes.
  3. On the last pass, leave at rounded edge for 10 seconds.
    • If successful, you should see 1 long LED flash.
    • If you do not see any flashes, then the reset process was not completed successfully.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Keep Strips close to its intended location during the add process.
  3. Remove both magnets. 1 long flash confirms proper inclusion to the Z-Wave network.
  4. Move the squared magnet away from the squared end and watch the status in the Hubitat Elevation™ device details to ensure proper functionality.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Remove both magnets. 1 long flash confirms proper exclusion to the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Sensative Strips
Drip
Water Sensor
Z-Wave Plus

Factory Reset

  1. Place magnet 2cm from the rounded edge for 2 seconds. You should see 1 short LED flash.
  2. Move between logo and the round edge 2 times.
  3. On the second pass, leave the magnet here for 10 seconds and wait for 1 long LED flash.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Move the Magnet towards the rounded edge until you see 2 LED flashes.
  3. Move magnet between logo and rounded edge slowly 2 times.
  4. Remove the magnet. If you see 1 LED flash, inclusion to the Z-wave network was successful.
  5. If you see 5 short LED flashes, then inclusion has failed and you should perform a factory reset, then repeat the inclusion process.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Move the magnet towards the rounded edge until 1 LED flashes.
  4. Move magnet between logo and rounded edge slowly 2 times.
  5. Remove the magnet. If you see 1 LED flash, it indicates sucessful exclusion from the Z-Wave network.
  6. If you see 5 short LED flashes, then exclusion has failed and you should perform a factory reset, then repeat the exclusion process.

Brand
Device
Product Number
Device Type
Protocol
Sensative Strips
Comfort
Temperature Sensor
Z-Wave Plus

Factory Reset

  1. Place magnet 2cm from the rounded edge for 2 seconds. You should see 1 short LED flash.
  2. Move between logo and the round edge 2 times.
  3. On the second pass, leave the magnet here for 10 seconds and wait for 1 long LED flash.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Move the Magnet towards the rounded edge until you see 2 LED flashes.
  3. Move magnet between logo and rounded edge slowly 2 times.
  4. Remove the magnet. If you see 1 LED flash, inclusion to the Z-wave network was successful.
  5. If you see 5 short LED flashes, then inclusion has failed and you should perform a factory reset, then repeat the inclusion process.

Exclusion from the Z-Wave Network

  1. From the device's details page, select Remove Device, then Remove
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Move the magnet towards the rounded edge until 1 LED flashes.
  4. Move magnet between logo and rounded edge slowly 2 times.
  5. Remove the magnet. If you see 1 LED flash, it indicates sucessful exclusion from the Z-Wave network.
  6. If you see 5 short LED flashes, then exclusion has failed and you should perform a factory reset, then repeat the exclusion process.

Shelly

Brand
Device
Product Number
Device Type
Protocol
Shelly
WiFi Dimmer
Dimmer
LAN

Factory Reset

  1. If the Device has been powered on, power it off and then on again.
  2. After turning the power on, you have 60 seconds to press 5 consecutive times on a connected switch.
  3. Alternatively, if you have physical access to the Device, press and hold the reset button for 10 seconds.
  4. When the LED indicator starts to flash quickly, release the button and your device should return to AP Mode.

Join the LAN

  1. In the Preferences field of the driver, enter the IP address of your Shelly device.
    • NOTE: You should reserve the IP address for your Shelly WiFi devices in your router, just as you do for your Hubitat Elevation™ hub. If you do not, the IP address will change when the DHCP lease on your router expires for connected IP devices. The result will be that the Shelly driver will no longer be able to find your device.

Leaving the LAN

  1. From the device's details page, select Remove Device, then Remove.
  2. If the Device has been powered on, power it off and then on again.
  3. After turning the power on, you have 60 seconds to press 5 consecutive times on a connected switch.
  4. Alternatively, if you have physical access to the Device, press and hold the reset button for 10 seconds.
  5. When the LED indicator starts to flash quickly, release the button and your device should return to AP Mode.

Brand
Device
Product Number
Device Type
Protocol
Shelly
WiFi Switch
Switch
LAN

Factory Reset

  1. If the Device has been powered on, power it off and then on again.
  2. After turning the power on, you have 60 seconds to press 5 consecutive times on a connected switch. You will hear the relay trigger itself.
  3. After the relay makes a triggering sound, the switch should return to AP Mode.
  4. Alternatively, if you have physical access to the Device, press and hold the reset button on the back of the device for 10 seconds.
  5. Your device should return to AP Mode.

Join the LAN

  1. In the Preferences field of the driver, enter the IP address of your Shelly device.
    • NOTE: You should reserve the IP address for your Shelly WiFi devices in your router, just as you do for your Hubitat Elevation™ hub. If you do not, the IP address will change when the DHCP lease on your router expires for connected IP devices. The result will be that the Shelly driver will no longer be able to find your device.

Leaving the LAN

  1. From the device's details page, select Remove Device, then Remove.
  2. If the Device has been powered on, power it off and then on again.
  3. After turning the power on, you have 60 seconds to press 5 consecutive times on a connected switch.
  4. Alternatively, if you have physical access to the Device, press and hold the reset button for 10 seconds.
  5. When the LED indicator starts to flash quickly, release the button and your device should return to AP Mode.

Sinope

Brand
Device
Product Number
Device Type
Protocol
Sinope
Zigbee Thermostats
Thermostat
Zigbee

Factory Reset

  1. Simultaneously press the UP and DOWN arrow buttons for 10 seconds
  2. On the thermostat display, the radio signal icon will disappear.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Simultaneously press the UP and DOWN arrow buttons to initiate device paring.
  3. On the thermostat display, a radio signal icon will flash while connecting, and will remain solid once connected to the hub.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Simultaneously press the UP and DOWN arrow buttons for 10 seconds.
  3. On the thermostat display, the radio signal icon will disappear.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Small Electrical Load Controller

RM3250ZB

Switch
Zigbee

Factory Reset

  1. Press the button next to the radio signal icon for 10 seconds.
  2. On the device, the LED next to the radio signal icon will turn off.
  3. All settings will be reset to factory defaults.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press the button next to the radio signal icon to initiate device paring.
  3. On the device, the LED next to the radio signal icon will flash while connecting, and will remain solid once connected to the hub.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the button next to the radio signal icon for 10 seconds.
  3. On the device, the LED next to the radio signal icon will turn off.
  4. All settings will be reset to factory defaults.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Water Leak Detector

WL4200

Water Sensor
Zigbee

Factory Reset

  1. Remove the battery cover.
  2. Press the Link button for 10 seconds.
  3. The LED will flash Green.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery cover.
  3. Press the Link button to initiate device paring.
    • The LED will flash Green while connecting.
    • The LED will remain solid Green for 10 seconds upon sucessful connection.
    • If the LED is flashing Red, the connection has failed.
  4. Test the sensor by exposing the electrodes to a damp cloth and observing the device status on Hubitat Elevation™

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the battery cover.
  3. Press the Link button for 10 seconds.
  4. The LED will flash Green.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Water Leak Detector

WL4200S

Water Sensor
Zigbee

Factory Reset

  1. Remove the battery cover.
  2. Press the Link button for 10 seconds.
  3. The LED will flash Green.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery cover.
  3. Press the Link button to initiate device paring.
    • The LED will flash Green while connecting.
    • The LED will remain solid Green for 10 seconds upon sucessful connection.
    • If the LED is flashing Red, the connection has failed.
  4. Test the sensor by exposing the electrodes to a damp cloth and observing the device status on Hubitat Elevation™

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the battery cover.
  3. Press the Link button for 10 seconds.
  4. The LED will flash Green.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Water Valve

VA4200WZ

Valve
Zigbee

Factory Reset

  1. Remove the battery cover.
  2. Ensure the switch is set to position 3 (Zigbee connection)
  3. Plug the valve power adapter into an AC outlet.
  4. Simultaneously press buttons A and B for 10 seconds.
  5. The LED will flash GREEN

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery cover.
  3. Ensure the switch is set to position 3 (Zigbee connection)
  4. Plug the valve power adapter into an AC outlet.
  5. Press the A button to initiate device paring
    • The LED will flash Green while connecting
    • The LED will remain solid Green for 10 seconds upon sucessful connection
    • If the LED is flashing Red, the connection has failed.
  6. Test the valve by toggling Open and Close in the device detail page on Hubitat Elevation™, and observe that the valve properly opens and closes in response to the pressing to the Open and Close buttons.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the battery cover.
  3. Ensure the switch is set to position 3 (Zigbee connection)
  4. Plug the valve power adapter into an AC outlet.
  5. Simultaneously press buttons A and B for 10 seconds.
  6. The LED will flash Green.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Smart Dimmer

DM2500ZB

Dimmer
Zigbee

Factory Reset

  1. Simultaneously press the up and down dimmer buttons for 10 seconds.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Simultaneously press the up and down dimmer buttons for 1 second.
    • The LED will flash Blue while connecting
    • The LED with flash Green when connected.
    • If the LED is flashing Red, the connection has failed.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Simultaneously press the up and down dimmer buttons for 10 seconds.

Brand
Device
Product Number
Device Type
Protocol
Sinope
Smart Switch

SW2500ZB

Switch
Zigbee

Factory Reset

  1. Simultaneously press the ON and OFF buttons for 10 seconds.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Simultaneously press the ON and OFF buttons for 1 second.
    • The LED will flash Blue while connecting
    • The LED with flash Green when connected.
    • If the LED is flashing Red, the connection has failed.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Simultaneously press the ON and OFF buttons for 10 seconds.

SmartThings

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Multi Sensor
3300-S
Contact Sensor
Zigbee

Factory Reset

  1. Hold the recessed connect button for 5 seconds.
  2. Release the button when the LED starts flashing Red.
  3. The LED will flash Red and Green while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.
  4. The LED will flash Red and Green while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the recessed connect button for 5 seconds.
  3. Release the button when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
SmartSense Multi Sensor
STSS-MULT-001
Contact Sensor
Zigbee

Factory Reset

  1. Hold the Connect button for 6 seconds, or until the LED light turns off.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Make sure the Outlet is within 15 feet (4.5 meters) of the hub during setup.
  3. Hold the Connect button for 6 seconds, or until the LED light turns off.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button for 6 seconds, or until the LED light turns off.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Multi Sensor (2015 Model)
F-SS-MULT-001
Contact Sensor
Zigbee

Factory Reset

  1. Hold the Connect button while inserting the battery.
  2. Release the button once the LED is lit.
  3. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.
  4. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Multi Sensor (2016 Model)
F-MLT-US-2
Contact Sensor
Zigbee

Factory Reset

  1. Remove the cover and hold the Connect button for 5 seconds.
  2. Release it when the LED starts flashing Red.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release it when the LED starts flashing Red.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release it when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Multi Sensor v4
STS-MLT-250
Contact Sensor
Zigbee

Factory Reset

  1. Hold the Connect button while inserting the battery.
  2. Release the button once the LED is lit.
  3. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.
  4. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Humidity Sensor
3310-S
Humidity Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove the cover, and then the battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount, remove the cover, and then the battery.
  3. While holding down the reset button, reinsert battery

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove the cover, and then the battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
SmartSense Moisture Sensor
Water Sensor
Zigbee

Factory Reset

  1. Remove the cover of the Moisture Sensor.
  2. Remove the CR2 battery by pulling the ribbon.
  3. Hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.
  5. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover of the Moisture Sensor.
  3. Remove the CR2 battery by pulling the ribbon.
  4. Hold the Connect button while inserting the battery.
  5. Release the button once the LED is lit.
  6. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover of the Moisture Sensor.
  3. Remove the CR2 battery by pulling the ribbon.
  4. Hold the Connect button while inserting the battery.
  5. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Water Leak Sensor v4 (2015)
Water Sensor
Zigbee

Factory Reset

  1. Remove the cover of the Water Leak Sensor.
  2. Remove the battery, then hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.
  4. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover of the Water Leak Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.
  5. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover of the Water Leak Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
SmartSense Motion Sensor
Motion Sensor
Zigbee

Factory Reset

  1. Hold the Connect button for 6 seconds or until the LED light turns off.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold the Connect button for 6 seconds or until the LED light turns off.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold the Connect button for 6 seconds or until the LED light turns off.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Motion Sensor v2 (2014)
Motion Sensor
Zigbee

Factory Reset

  1. Remove the cover of the Motion Sensor.
  2. Remove the battery, then hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.
  4. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover of the Motion Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.
  5. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover of the Motion Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Motion Sensor v3 (2015)
Motion Sensor
Zigbee

Factory Reset

  1. Remove the cover of the Motion Sensor.
  2. Remove the battery, then hold the Connect button while inserting the battery.
  3. Release the button once the LED is lit.
  4. The LED will flash Blue while attempting to connect.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover of the Motion Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.
  5. The LED will flash Blue while attempting to connect.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover of the Motion Sensor.
  3. Remove the battery, then hold the Connect button while inserting the battery.
  4. Release the button once the LED is lit.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Motion Sensor v4 (2016)
Motion Sensor
Zigbee

Factory Reset

  1. Remove the cover and hold the Connect button for 5 seconds.
  2. Release it when the LED starts flashing Red.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release it when the LED starts flashing Red.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release it when the LED starts flashing Red.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
SmartSense Presence Sensor v2
Presence Sensor
Zigbee

Factory Reset

  1. Insert a small flathead screwdriver into the groove at the base of the SmartSense Presence Sensor
  2. Gently twist the screwdriver and the plastic case should pop open.
  3. Hold the Connect button on the sensor for about 6 seconds until the LED light turns off, and then release.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Insert a small flathead screwdriver into the groove at the base of the SmartSense Presence Sensor
  3. Gently twist the screwdriver and the plastic case should pop open.
  4. Hold the Connect button on the sensor for about 6 seconds until the LED light turns off, and then release.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Insert a small flathead screwdriver into the groove at the base of the SmartSense Presence Sensor
  3. Gently twist the screwdriver and the plastic case should pop open.
  4. Hold the Connect button on the sensor for about 6 seconds until the LED light turns off, and then release.

Brand
Device
Product Number
Device Type
Protocol
SmartThings
Arrival Sensor v4
Presence Sensor
Zigbee

Factory Reset

  1. Remove the cover and hold the Connect button for 5 seconds.
  2. Release the button when the LED turns off.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release the button when the LED turns off.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the cover and hold the Connect button for 5 seconds.
  3. Release the button when the LED turns off.

Sunricher

Brand
Device
Product Number
Device Type
Protocol
Sunricher
Wall mounted controller
ZG2833K8_EU05
Button Controller
Zigbee

Factory Reset

  1. Hold down the two top buttons until the LED lights up solid.
  2. Immiediatley press the second button from the top, on the left side of the controller 5 times.
  3. The LED will flash 3 times to indicate a sucessful reset of the device.

Join the Zigbee Network

  1. Hold down the two top buttons until the LED lights up solid.
  2. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  3. Press the second button from the top, on the rightside of the controller

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold down the two top buttons until the LED lights up solid.
  3. Immiediatley press the second button from the top, on the left side of the controller 5 times.
  4. The LED will flash 3 times to indicate a sucessful reset of the device.

Brand
Device
Product Number
Device Type
Protocol
Sunricher
AC Phase-Cut Dimmer
ZG9101SAC-HP
Dimmer
Zigbee

Factory Reset

  1. Apply power to the device to start TouchLink Commissioning. You have 180 seconds before timeout. Repeat the operation if you exceed the timeout period.
  2. Bring the remote or touch panel within 10 cm of the device.
  3. Set the remote or touch panel into Touch Reset procedure to reset the device, please refer to the corresponding remote or touch panel manual to learn how.
  4. There will be an indication on the remote and a connected light will flash 3 times to indicate a successful reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Apply power to the device to set it into network pairing mode.
  3. A connected light will flash twice slowly. You have 15 seconds before timeout. Repeat the operation if you exceed the timeout period.
  4. A connected light will flash 5 times and then stay ON solid.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Perform a factory reset using the above procedure.

Sylvania

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ Contact and Temp Sensor
74388
Contact Sensor
Zigbee

Factory Reset

  1. Slide the sensor off the mount, remove cover, and remove battery.
  2. While holding down the reset button, reinsert battery to factory reset the device.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Slide the sensor off the mount and remove cover. Remove battery for 10 seconds and replace

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Slide the sensor off the mount, remove cover, and remove battery.
  3. While holding down the reset button, reinsert battery to factory reset the device.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ Motion and Temp Sensor
72923
Motion Sensor
Zigbee

Factory Reset

  1. Hold down the Pairing/Reset button for more than 10 seconds.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold down the Pairing/Reset button for more than 10 seconds.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold down the Pairing/Reset button for more than 10 seconds.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ Dimmer
73743
Button Controller
Zigbee

Factory Reset

  1. Press and hold both the top and bottom button for 3 seconds

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Press and hold both the top and bottom button for 3 seconds

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press and hold both the top and bottom button for 3 seconds

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ 4 Button Switch
74099
Button Controller
Zigbee

Factory Reset

  1. Hold buttons 1 and 4 together. The LED will flash Red.
  2. Keep holding buttons 1 and 4 until the LED on the device stops flashing.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Hold buttons 2 and 3 until the LED on the device starts flashing Yellow.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Hold buttons 1 and 4 together. The LED will flash Red.
  3. Keep holding buttons 1 and 4 until the LED on the device stops flashing.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ Outlet
72922
Outlet
Zigbee

Factory Reset

  1. Make sure the plug is powered on. The light will be orange.
  2. Press the button located on the front of the plug and hold it down for 10 seconds.
  3. The light will flash orange when it has been reset.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Make sure the plug is powered on. The light will be orange.
  3. Press the button located on the front of the plug and hold it down for 10 seconds.
  4. The light will flash orange when it has been reset and is ready to be paired.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Make sure the plug is powered on. The light will be orange.
  3. Press the button located on the front of the plug and hold it down for 10 seconds.
  4. The light will flash orange when it has been reset.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart bulbs
Bulb
Zigbee

Factory Reset

  1. Turn the light off.
  2. Turn the light on for 3 seconds.
  3. Turn the light off.
  4. Repeat this cycle 5 times.
  5. Wait 10 seconds for the light to flash 3 times.
  6. Repeat these steps if the light does not flash 3 times.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Turn the light off.
  3. Turn the light on for 3 seconds.
  4. Turn the light off.
  5. Repeat this cycle 5 times.
  6. Wait 10 seconds for the light to flash 3 times.
  7. Repeat these steps if the light does not flash 3 times.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Turn the light off.
  3. Turn the light on for 3 seconds.
  4. Turn the light off.
  5. Repeat this cycle 5 times.
  6. Wait 10 seconds for the light to flash 3 times.
  7. Repeat these steps if the light does not flash 3 times.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ BR30 bulb

74988

Bulb
Zigbee

Factory Reset

  1. Start with the Sylvania bulb in the ON position.
  2. Turn the bulb OFF and ON 8 times in a row, pausing for 1 second each time you turn the bulb ON or OFF.
  3. After the eighth time OFF, turn ON the bulb and leave it ON.
  4. Wait about 5 seconds.
  5. The BR30 bulb will flash if successfully reset.
  6. Repeat these steps if the light does not flash.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Start with the Sylvania bulb in the ON position.
  3. Turn the bulb OFF and ON 8 times in a row, pausing for 1 second each time you turn the bulb ON or OFF.
  4. After the eighth time OFF, turn ON the bulb and leave it ON.
  5. Wait about 5 seconds.
  6. The BR30 bulb will flash if it entered pairing mode successfully.
  7. Repeat these steps if the light does not flash.

Leaving the Zigbee Network

  1. Start with the Sylvania bulb in the ON position.
  2. Turn the bulb OFF and ON 8 times in a row, pausing for 1 second each time you turn the bulb ON or OFF.
  3. After the eighth time OFF, turn ON the bulb and leave it ON.
  4. Wait about 5 seconds..
  5. The BR30 bulb will flash if successfully reset.
  6. Repeat these steps if the light does not flash.

Brand
Device
Product Number
Device Type
Protocol
Sylvania
Smart+ Flex RGBW
Bulb
Zigbee

Factory Reset

  1. Start with the Light Strip powered ON.
  2. Repeat 5 times - Unplug for 1 second and then plug in for 1 second.
  3. On the fifth time plugging in the Light Strip, leave it plugged in.
  4. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset and ready for pairing.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Start with the Light Strip powered ON.
  3. Repeat 5 times - Unplug for 1 second and then plug in for 1 second.
  4. On the fifth time plugging in the Light Strip, leave it plugged in.
  5. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset and ready for pairing.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Start with the Light Strip powered ON.
  3. Repeat 5 times - Unplug for 1 second and then plug in for 1 second.
  4. On the fifth time plugging in the Light Strip, leave it plugged in.
  5. After about 3 seconds, the Light Strip will flash rapidly 3 times to show a successful reset.

Telguard

Brand
Device
Product Number
Device Type
Protocol
Telguard
Garage Door Control Switch

GDC1

Switch
Z-Wave

Factory Reset

  1. Plug in the GDC1.
  2. Remove the cover of the enclosure.
  3. Press the Z-Wave button once to reset the device.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button once to join the GDC1 for your Z-Wave network.
  3. If the device fails to join the Z-Wave network, unplug it for 10 seconds.
  4. Repeat step 1 and again press the Z-Wave button.
  5. Replace the cover of the enclosure.

Exclusion from the Z-Wave Network

  1. Plug in the GDC1.
  2. Remove the cover of the enclosure.
  3. From the device's details page, select Remove Device, then Remove.
  4. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  5. Press the Z-Wave button once to exclude the GDC1 from the Z-Wave network.

Telldus

Brand
Device
Product Number
Device Type
Protocol
Telldus
Plug-in ON/OFF switch

TZWP-100

Switch
Z-Wave

Factory Reset

  1. Plug in the device.
  2. Press and hold the button until the LED starts flashing white after approximately 6 seconds.
  3. Short-press the button once more.
  4. The device will now reset to factory defaults and the LED will flash red, indicating that it’s no longer part of the Z-Wave network.

Join the Z-Wave Network

  1. Plug in the dimmer module.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the button 3 times within 1.5 seconds to enter inclusion mode.

Exclusion from the Z-Wave Network

  1. Plug in the dimmer module.
  2. From the device's details page, select Remove Device, then Remove.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Press the button 3 times within 1.5 seconds to enter exclusion mode.

Third Reality

Brand
Device
Product Number
Device Type
Protocol
Third Reality
Reality Switch
Switch
Zigbee

Factory Reset

  1. Press the button on the front of the device for approximately 30 seconds.
  2. The LED will light steady for several seconds, then it will begin to flash rapidly
  3. The device has been reset and is ready for pairing.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Start with the Light Strip powered ON.
  3. Press the button on the front of the device for approximately 30 seconds.
  4. The LED will light steady for several seconds, then it will begin to flash rapidly

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Press the button on the front of the device for approximately 30 seconds.
  3. The LED will light steady for several seconds, then it will begin to flash rapidly
  4. The device has been reset and is ready for pairing.

TKB

Brand
Device
Product Number
Device Type
Protocol
TKB
TKB Dimmer Socket

TZ67

Dimmer
Z-Wave Plus

Factory Reset

  1. Plug in the dimmer module.
  2. Press the ON/OFF button 3 times within 1.5 seconds to enter inclusion mode.
  3. Within 3 seconds, press andhold the ON/OFF button for 5 seconds.

Join the Z-Wave Network

  1. Plug in the dimmer module.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the ON/OFF button 3 times within 1.5 seconds to enter inclusion mode.

Exclusion from the Z-Wave Network

  1. Plug in the dimmer module.
  2. From the device's details page, select Remove Device, then Remove.
  3. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  4. Press the ON/OFF button 3 times within 1.5 seconds to enter exclusion mode.

Utilitech

Brand
Device
Product Number
Device Type
Protocol
Utilitech
Indoor Siren
TSE07
Siren
Z-Wave

Factory Reset

  1. Remove the battery cover.
  2. Press the pairing button in between the batteries 8 times, 1 second apart.

Join the Z-Wave Network

  1. Remove the battery cover.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press the paring button once.

Exclusion from the Z-Wave Network

  1. Remove the battery cover
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the paring button once.

Vision

Brand
Device
Product Number
Device Type
Protocol
Vision
Siren & Strobe
ZM1601US-3
Siren
Z-Wave

Factory Reset

  1. Remove the mounting bracket and press the program button for at least 1 second & release.
  2. The LED light will turn flash indicating the device is reset to factory defaults and excluded from the Z-Wave network.

Join the Z-Wave Network

  1. The distance between the siren and the hub is suggested to be in 1 meter ( 3 feet ) or less.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Remove the mounting bracket and press the program button for at least 1 second & release.
  4. The LED light will turn off after inclusion.
  5. If the device is not included, it will continue in auto include more, attempting every 4-6 seconds for up to 4 attempts.
  6. The LED light will flash again if the siren has not been included.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Remove the mounting bracket and press the program button for at least 1 second & release.
  3. The LED light will turn flash upon successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Vision
Siren & Strobe
ZM1601US-5
Siren
Z-Wave

Factory Reset

  1. Remove the mounting bracket and press the program button for at least 1 second & release.
  2. The LED light will turn flash indicating the device is reset to factory defaults and excluded from the Z-Wave network.

Join the Z-Wave Network

  1. The distance between the siren and the hub is suggested to be in 1 meter ( 3 feet ) or less.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Remove the mounting bracket and press the program button for at least 1 second & release.
  4. The LED light will turn off after inclusion.
  5. If the device is not included, it will continue in auto include more, attempting every 4-6 seconds for up to 4 attempts.
  6. The LED light will flash again if the siren has not been included.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Remove the mounting bracket and press the program button for at least 1 second & release.
  3. The LED light will turn flash upon successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Vision
Shock Sensor
ZS5101
Acceleration Sensor
Z-Wave

Factory Reset

  1. Push the Tamper switch while inserting the battery & holding the Tamper switch for 5 seconds
  2. The device will reset to the factory defaults and the LED will will remain ON solid
  3. Remove the battery and re-inset it to complete the reset process.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the program button for at least 1 second & release.
  3. The LED light will turn off after inclusion.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the program button for at least 1 second & release.
  3. The LED light will turn off after exclusion.

Visonic

Brand
Device
Product Number
Device Type
Protocol
Visonic
Door/Window Sensor
MCT-340
Contact Sensor
Zigbee

Factory Reset

  1. Remove the battery cover.
  2. Press and hold down the sensor’s tamper switch.
  3. Insert the battery into the sensor while observing battery polarity.
  4. Release the tamper switch within 4 seconds.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Remove the battery cover.
  3. Press and release the tamper switch for 1-2 seconds.
  4. The LED will flash 3 times, every 5 seconds, repeating this cycle up to 20 times until paired.
  5. Test if the the sensor paired properly by moving the magnet away and toward it, observing the Hubitat Elevation™ device details status.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove the battery cover.
  3. Press and hold down the sensor’s tamper switch.
  4. Insert the battery into the sensor while observing battery polarity.
  5. Release the tamper switch within 4 seconds.

WaterCop

Brand
Device
Product Number
Device Type
Protocol
WaterCop
Emergency Water Shut-Off
WAT171021
Valve
Z-Wave

Factory Reset

  1. Press the Mode button once.
  2. The status light will start flashing periodically (3-4 times) indicating the device has been reset and excluded from the Z-Wave network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Ensure that the status light is flashing periodically (3-4 times).
  3. Press the Mode button once.
  4. The status light will stop flashing upon inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the Mode button once.
  3. The status light will start flashing periodically (3-4 times) indicating the device has been excluded from the Z-Wave network.

Wireless

Brand
Device
Product Number
Device Type
Protocol
Wireless
Smoke Detector
ZWN-SD
Valve
Z-Wave

Factory Reset

  1. Briefly press the program button on the back of the device.
  2. The status LED will light up and then imeadiatly turn off.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Briefly press the program button on the back of the device.
  3. The status LED will light up for 5 seconds and then turn off upon successful inclusion to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Briefly press the program button on the back of the device.
  3. The status LED will light up and then imeadiatly turn off upon successful exclusion from the Z-Wave network.

Xfinity

Brand
Device
Product Number
Device Type
Protocol
Xfinity
Keypad
3400-X
Keypad
Zigbee

Factory Reset

  1. Remove batteries from keypad.
  2. Press and hold the wall tamper switch while reinstalling the batteries.
  3. Once the keypad illuminates, release the wall tamper switch.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Perform a factory reset.
  3. Remove and reinstall the batteries to being device pairing

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Remove batteries from keypad.
  3. Press and hold the wall tamper switch while reinstalling the batteries.
  4. Once the keypad illuminates, release the wall tamper switch.

Yale

Brand
Device
Product Number
Device Type
Protocol
Yale
Yale Zigbee Locks
Lock
Zigbee

Factory Reset

  1. Remove the battery cover and batteries.
  2. Remove the interior escutcheon to access the reset button.
  3. The reset button is located beside the PCB cable connector.
  4. While pressing the reset button for a minimum of 3 seconds, reinstall the batteries.
  5. Release reset button and replace battery cover. NOTE: Upon reset, Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Enter the master pin code and then press the button with the Gear icon on it.
  3. Press 7 on the keypad to enter network setup mode.
  4. Press 1 to join the Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Enter the master pin code and then press the button with the Gear icon on it.
  3. Press 7 on the keypad to enter network setup mode.
  4. Press 3 to leave the Zigbee network.

Brand
Device
Product Number
Device Type
Protocol
Yale
Yale Z-Wave Locks
Lock
Z-Wave

Factory Reset

  1. Remove the battery cover and batteries.
  2. Remove the interior escutcheon to access the reset button.
  3. The reset button is located beside the PCB cable connector.
  4. While pressing the reset button for a minimum of 3 seconds, reinstall the batteries.
  5. Release reset button and replace battery cover. NOTE: Upon reset, Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Enter the master pin code and then press the button with the Gear icon on it.
  3. Press 7 on the keypad to enter network setup mode.
  4. Press 1 to include the lock in the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Enter the master pin code and then press the button with the Gear icon on it.
  3. Press 7 on the keypad to enter network setup mode.
  4. Press 3 to exclude the lock from the Z-Wave network.

Yeelight

Brand
Device
Product Number
Device Type
Protocol
Yeelight
Yeelight Mono / CT bulbs
Bulb
LAN

Factory Reset

  1. Switch the bulb on and off 5 times in a row (2 seconds ON and 2 seconds OFF).
  2. The bulb will start pulsing slowly up and down.
  3. After 5 seconds, it will restart automatically, which means the bulb has been reset to factory defaults.

Join the LAN

  1. From the Hubitat Web Interface home page, select Apps.
  2. Choose Yeelight Integration from the list of Hubitat Elevation™ Built-In Apps
    • See Apps documentation for more detail.
  3. Using the Yeelight mobile app, enable LAN Control for each Yeelight prior to starting discovery. The LAN Control option can be enabled by selecting the lower right icon in the mobile app menu for each bulb.
  4. Open the Yeelight setup and start bulb discovery.

Leaving the LAN

  1. From the device's details page, select Remove Device, then Remove.
  2. Switch the bulb on and off 5 times in a row (2 seconds ON and 2 seconds OFF).
  3. The bulb will start pulsing slowly up and down.
  4. After 5 seconds, it will restart automatically, which means the bulb has been reset.

Brand
Device
Product Number
Device Type
Protocol
Yeelight
Yeelight Color bulbs
Bulb
LAN

Factory Reset

  1. Switch the bulb on and off 5 times in a row (2 seconds ON and 2 seconds OFF).
  2. The bulb will start flashing
  3. After 5 seconds, it will turn white, which means the bulb has been reset to factory defaults.

Join the LAN

  1. From the Hubitat Web Interface home page, select Apps.
  2. Choose Yeelight Integration from the list of Hubitat Elevation™ Built-In Apps
    • See Apps documentation for more detail.
  3. Using the Yeelight mobile app, enable LAN Control for each Yeelight prior to starting discovery. The LAN Control option can be enabled by selecting the lower right icon in the mobile app menu for each bulb.
  4. Open the Yeelight setup and start bulb discovery.

Leaving the LAN

  1. From the device's details page, select Remove Device, then Remove.
  2. Switch the bulb on and off 5 times in a row (2 seconds ON and 2 seconds OFF).
  3. The bulb will start flashing
  4. After 5 seconds, it will turn white, which means the bulb has been reset to factory defaults.

Zen

Brand
Device
Product Number
Device Type
Protocol
Zen
Thermostat

ZEN-01

Thermostat
Zigbee

Factory Reset

  1. To do a full factory reset, which will delete all your configuration settings and your network connectivity, you need to remove the device from the wall and press the CONFIG button 20 times.
    • NOTE: Performing a Factory Reset will reset your ZEN's HVAC-system configuration and all of your preferences and advanced settings changes. If you do a Factory Reset, make sure that you set your configuration code and preferences back to their correct values before replacing the display on the wall.

Join the Zigbee Network

  1. From the Hubitat Web Interface home page, select Zigbee on the Device Discovery page to start device discovery.
  2. Pull the ZEN display off the wall and press the Network button on the rear of the display 5 times.
  3. You should see the network icon flashing on the front of the display indicating that your ZEN thermostat is attempting to connect to a network.
  4. The thermostat will indicate it is connected to Hubitat Elevation™ by a Network icon on the front of the device.
  5. If the network icon is flashing, the ZEN is trying to find your network. The network icon will be solid when you are connected to your Zigbee network.

Leaving the Zigbee Network

  1. From the device's details page, select Remove Device, then Remove.
  2. Pull the ZEN display off the wall and press the Network button on the rear of the display 10 times.
  3. The Network icon will turn OFF when the thermostat disconnects from the Zigbee network.

Zipato

Brand
Device
Product Number
Device Type
Protocol
Zipato
Siren

PH-PSE02

Lock
Z-Wave

Factory Reset

  1. Press tamper key 4 times within 1.5 seconds, but do not release the tamper key in the 4th press.
  2. The LED will stay ON solid for 3 seconds and then will turn OFF.
  3. Within 2 seconds of the LED turning OFF, release the tamper key. If successful, the LED will turn ON for 1 second.
  4. If reset fails, the LED will flash once.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the tamper key 3 times within 1.5 seconds to enter inclusion mode.
  3. After successful inclusion, the LED will light up for 1 second.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the tamper key 3 times within 1.5 seconds to enter exclusion mode.

ZLINK

Brand
Device
Product Number
Device Type
Protocol
ZLINK
Dimmer

ZL-WD-100

Dimmer
Z-Wave Plus

Factory Reset

  1. Turn on the connected lighting with the rocker.
  2. Quickly tap on the top of the rocker 3 times.
  3. Now quickly tap on the bottom of the rocker 3 times.
  4. When reset is successful, the light will turn off and on again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the rocker switch once to include the device in the Z-Wave network.
  3. If inclusion fails, perform a factory reset, then try to include the device in the Z-Wave network again.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the rocker switch once to exclude the device from the Z-Wave network.
  3. If exclusion fails, perform a factory reset.

Brand
Device
Product Number
Device Type
Protocol
ZLINK
Switch

ZL-WS-100

Switch
Z-Wave Plus

Factory Reset

  1. Turn on the connected lighting with the rocker.
  2. Quickly tap on the top of the rocker 3 times.
  3. Now quickly tap on the bottom of the rocker 3 times.
  4. When reset is successful, the light will turn off and on again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the rocker switch once to include the device in the Z-Wave network.
  3. If inclusion fails, perform a factory reset, then try to include the device in the Z-Wave network again.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the rocker switch once to exclude the device from the Z-Wave network.
  3. If exclusion fails, perform a factory reset.

Zooz

Brand
Device
Product Number
Device Type
Protocol
Zooz
Smart Plug

ZEN06

Outlet
Z-Wave Plus

Factory Reset

  1. Plug the smart plug into a grounded receptacle.
  2. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  3. The LED indicator will stay solid yellow for 2 seconds to indicate successful reset and the plug will then automatically turn off.

Join the Z-Wave Network

  1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave radio.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the Z-Wave button 3 times quickly.
  4. The LED indicator will flash blue.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the Z-Wave button 3 times quickly to exclude it from the Z-Wave network.
  3. LED indicator will flash orange.
  4. The LED indicator will remain solid orange for a few seconds to indicate successful exclusion from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Power Switch

ZEN15

Switch
Z-Wave Plus

Factory Reset

  1. Plug the power switch into a grounded receptacle.
  2. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  3. The LED indicator will flash orange and then stay solid orange for 2 seconds to indicate successful reset and the switch will then automatically turn off.

Join the Z-Wave Network

  1. Plug the smart plug into a grounded receptacle located within 3 feet from your Z-Wave radio.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the Z-Wave button 3 times quickly.
  4. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once included to the Z-Wave network.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the Z-Wave button 3 times quickly to exclude it from the Z-Wave network.
  3. LED indicator will flash orange.
  4. The LED indicator will start flashing blue, then turn blue (on) or pink (off) once excluded from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
MultiRelay

ZEN16

Switch
Z-Wave Plus

Factory Reset

  1. Press the Z-Wave button 4 times quickly.
  2. The LED indicator will light up, then quickly press the Z-Wave button 4 times again.
  3. If theLED indicator flashes 3 times then turns oft, reset was successful.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button 5 times quickly to add the MultiRelay to your network.
  3. The LED indicator will flash to signal communication and remain on for 2 seconds to confirm inclusion.

Exclusion from the Z-Wave Network

  1. Bring your MultiRelay close to the hub and ensure is has power.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave button 3 times quickly.
  4. Hubitat Elevation™ will confirm exclusion and the MultiRelay will disappear from the device list.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Power Strip Ver 2.0

ZEN20

Power Strip
Z-Wave Plus

Factory Reset

  1. Plug the Power Strip into a grounded receptacle.
  2. Tap the CH1 button 3 times and hold on the third tap for at least 10 seconds.
  3. All LED indicators will flash to confirm successful reset.

Join the Z-Wave Network

  1. Plug the Power Strip into a grounded receptacle you’re planning to use it at (it doesn’t need to be close to the hub).
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Press and release the CH1 button 3 times quickly.
  4. All LED indicators will start flashing.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press and release the CH1 button 3 times quickly.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Smart Switch

ZEN21

Switch
Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash to signal communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Dimmer Switch

ZEN22

Dimmer
Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash to signal communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
ON/OFF Toggle Switch

ZEN23

Switch
Z-Wave Plus

Factory Reset

  1. Toggle the switch down 3 times and hold on the third toggle for at least 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Toggle the switch up 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Toggle the switch down 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Dimmer Toggle Switch

ZEN24

Dimmer
Z-Wave Plus

Factory Reset

  1. Toggle the switch down 3 times and hold on the third toggle for at least 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Toggle the switch up 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Toggle the switch down 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Double Plug

ZEN25

Outlet
Z-Wave Plus

Factory Reset

  1. Press the Z-Wave button 3 times and hold on the third press for at least 10 seconds.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button 3 times quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the Z-Wave button 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
S2 ON/OFF Switch

ZEN26

Switch
Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash and will remain ON for 2 seconds to indicate successful communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
S2 Dimmer Switch

ZEN27

Dimmer
Z-Wave Plus

Factory Reset

  1. Tap the upper paddle 3 times and hold on the third tap for at least 10 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Tap the top paddle 3 times quickly.
  3. The LED indicator will flash and will remain ON for 2 seconds to indicate successful communication.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Tap the bottom paddle 3 times quickly to exclude it from the Z-Wave network.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Double Switch

ZEN30

Switch
Z-Wave Plus

Factory Reset

  1. Press and hold the lower paddle on the dimmer for at least 15 seconds until the LED indicators start flashing, then release.
  2. Immediately press and hold the upper paddle on the dimmer for at least 15 seconds.
  3. The LED indicators will flash again to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the upper paddle 3 times quickly to include the device in the Z-Wave network.
  3. The LED will flash to indicate communication with the hub and will stay on for 2 seconds indicate it has been successfully added to your network.

Exclusion from the Z-Wave Network

  1. Bring your Hubitat Elevation™ hub close to the RGBW Dimmer if possible.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the lower paddle 3 times quickly to exclude it from the Z-Wave network.
Brand
Device
Product Number
Device Type
Protocol
Zooz
RGBW Dimmer

ZEN31

Dimmer
Z-Wave Plus

Factory Reset

  1. Press and hold the Z-Wave button to enter reset mode.
  2. Release the button when the LED indicator glows Yellow, then quickly press the Z-Wave button again to confirm factory reset.
  3. Wait a few seconds until the device resets and restarts.
  4. The LED indicator will light up in Red when it’s ready.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the Z-Wave button 3 times quickly to include the device in the Z-Wave network.
  3. The LED will flash Yellow to indicate communication with the hub.
  4. The LED will flash Green to indicate it has been successfully added to your network.
  5. If inclusion fails, the LED will flash Red.

Exclusion from the Z-Wave Network

  1. Bring your Hubitat Elevation™ hub close to the RGBW Dimmer if possible.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  3. Press the Z-Wave button on the device 3 times quickly.
  4. The LED indicator on the RGBW Dimmer will light up in Red, and the device will disappear from the devices list.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Motion Sensor

ZSE02

Motion Sensor
Z-Wave Plus

Factory Reset

  1. Please press the Z-Wave button 6 TIMES quickly (3 unlock-lock cycles).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Bring the motion sensor within direct reach of your Z-Wave radio.
  3. Quickly press the Z-Wave button on the motion sensor 2 times (unlock and then lock).
  4. Make sure the button is pushed in (locked) when you finish the process to re-enable motion detection.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press the Z-Wave button on the motion sensor 2 times (unlock and then lock).

Brand
Device
Product Number
Device Type
Protocol
Zooz
Motion and Light Mini Sensor

ZSE09

Motion Sensor
Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds.
  2. The LED indicator flashes 1 time and it may then flash 5 times to indicate the device is no longer part of Z-Wave network.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Mini Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Mini Sensor 3 times.
  3. The LED indicator will flash quickly.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Motion Sensor

ZSE18

Motion Sensor
Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 20 seconds.
  2. The LED indicator will turn on then turn on solid and will then automatically turn off.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the 3 times.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Multisiren

ZSE19

Siren
Z-Wave Plus

Factory Reset

  1. Press the Z-Wave button 4 times and hold on the fourth press for at least 5 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 3 times.

Brand
Device
Product Number
Device Type
Protocol
Zooz
S2 Outdoor Motion Sensor

ZSE29

Motion Sensor
Z-Wave Plus

Factory Reset

  1. Press the tamper switch 4 times and hold on the fourth press for at least 5 seconds.
  2. The LED indicator will flash to confirm successful reset.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the tamper switch 4-5 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the tamper switch 3 times.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Water Sensor

ZSE30

Water Sensor
Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Smart Chime

ZSE33

Doorbell
Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the Z-Wave button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button on the Water Sensor 3 times.
  3. The LED indicator will flash quickly.

Brand
Device
Product Number
Device Type
Protocol
Zooz
4 in 1 Sensor

ZSE40

Motion Sensor
Z-Wave Plus

Factory Reset

  1. OPEN the back cover to trigger tamper switch.
  2. Press and release the Z-Wave button using a paperclip 10 times quickly (within 10 seconds).
  3. The sensor will start flashing immediately and will again flash 5 times after the 10 clicks (color depends on room temperature, it’s usually blue or yellow).

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 2 times with a paperclip.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press and release the Z-Wave button 2 times with a paperclip.

Brand
Device
Product Number
Device Type
Protocol
Zooz
Water Valve

ZAC03

Valve
Z-Wave Plus

Factory Reset

  1. PRESS AND HOLD the RED power button for at least 10 seconds until the LED indicator flashes 1 time.

Join the Z-Wave Network

  1. Connect the valve to power.
  2. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  3. Quickly press the RED power button on the valve control 3 times.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Quickly press the RED power button on the valve control 3 times.

ZWP

Brand
Device
Product Number
Device Type
Protocol
ZWP
Dimmer

ZWP WD-100

Dimmer
Z-Wave Plus

Factory Reset

  1. Turn on the connected lighting with the rocker.
  2. Quickly tap on the top of the rocker 3 times.
  3. Now quickly tap on the bottom of the rocker 3 times.
  4. When reset is successful, the light will turn off and on again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the rocker switch once to include the device in the Z-Wave network.
  3. If inclusion fails, perform a factory reset, then try to include the device in the Z-Wave network again.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the rocker switch once to exclude the device from the Z-Wave network.
  3. If exclusion fails, perform a factory reset.

Brand
Device
Product Number
Device Type
Protocol
ZWP
Switch

ZWP WS-100

Switch
Z-Wave Plus

Factory Reset

  1. Turn on the connected lighting with the rocker.
  2. Quickly tap on the top of the rocker 3 times.
  3. Now quickly tap on the bottom of the rocker 3 times.
  4. When reset is successful, the light will turn off and on again.

Join the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Inclusion on the Device Discovery page.
  2. Press the rocker switch once to include the device in the Z-Wave network.
  3. If inclusion fails, perform a factory reset, then try to include the device in the Z-Wave network again.

Exclusion from the Z-Wave Network

  1. From the Hubitat Web Interface home page, select Z-Wave, then Start Z-Wave Exclusion on the Device Discovery page.
  2. Press the rocker switch once to exclude the device from the Z-Wave network.
  3. If exclusion fails, perform a factory reset.

*Note: Aeotec was formerly known as Aeon Labs.